Notifications on Sewer Cad!

Dear All,

I am having trouble on the notifications I got on my model which says "Directed Node has invalid downstream Link" and "Reference to a deleted or inactive downstream pipe". When I zoom-in to the element they are talking about, it go to the pumps(highlighted on red). What do these notification means?

What I did to trouble shoot did is that, I redraw the model of the downstream pipe of the pipe, but unfortunately it doesn't work.

Please Help!

Thanks & Regards,

June

Parents
  • Double-click on the pump then look at the properties for the Downstream Pipe.  This should tell you what the downstream link is.  From these two messages, it seems that the downstream pipe the pump is referencing is missing or inactive.  Check your model to see if the pipe is deleted/inactive and make sure the pump is connected to an active pipe.

    Terry Foster
    Technical Support
    Hydraulics and Hydrology product line
    Bentley Systems, Inc.


Reply
  • Double-click on the pump then look at the properties for the Downstream Pipe.  This should tell you what the downstream link is.  From these two messages, it seems that the downstream pipe the pump is referencing is missing or inactive.  Check your model to see if the pipe is deleted/inactive and make sure the pump is connected to an active pipe.