This discussion has been locked.
You can no longer post new replies to this discussion. If you have a question you can start a new discussion

WaterCAD MSX with User Data Extensions

Hi Everyone!

I try to run a Multiple Species Analysis on a large (30.000 pipes) model.

I have 2 additional properites (parameter) for every single pipe.

I tried to initialize the parameters in the Model Configuration text input, but that box is limited in row numbers.... it can only contain ~1290 rows. Unfortunately, I have to add these parameters as a function of the material and wall thickness of the pipes, so i cannot use a default value...

I tried to find a workaround by adding user data extensions of the same name, and imported the values of the parameters pipe by pipe, but it seems like it has no effect.

The manual said (i was afraid of this...)

Note: The user data does not affect the hydraulic model calculations. However, their behavior concerning
capabilities like editing, annotating, sorting and database connections is identical to any of the standard predefined
attributes.

Do you know any workaround for this limitation?

Parents
  • Hello Attila,

    In my testing using the latest version (10.00.00.50), the Multi-Species Analysis Model Configuration dialog is not limited by the number of rows but rather by the number of characters. The limit appears to be around 32767 characters. I will ask one of our developers about this and will get back to you. What version are you using?


    Regards,

    Jesse Dringoli
    Technical Support Manager, OpenFlows
    Bentley Communities Site Administrator
    Bentley Systems, Inc.

  • Hi Attila,

    I confirmed that the limit is currently 32767 characters. I'd like to open a Service Request and discuss this offline with you but cannot locate your account. I have sent you a private message regarding this.

    Thanks,


    Regards,

    Jesse Dringoli
    Technical Support Manager, OpenFlows
    Bentley Communities Site Administrator
    Bentley Systems, Inc.

Reply
  • Hi Attila,

    I confirmed that the limit is currently 32767 characters. I'd like to open a Service Request and discuss this offline with you but cannot locate your account. I have sent you a private message regarding this.

    Thanks,


    Regards,

    Jesse Dringoli
    Technical Support Manager, OpenFlows
    Bentley Communities Site Administrator
    Bentley Systems, Inc.

Children