Una pregunta mas, como calculo el volumen inicial de gas? o de líquido?

Muchas Gracias
Parents
  • En inglés:

    Hello,

    The answer depends on the tank configuration. Assuming you're using HAMMER V8i or CONNECT Edition:

    When "treat as junction" is set to "false", the initial liquid volume and full tank volume are values that you must enter, and the initial gas volume is derived as the difference between the two. When "treat as junction" is set to "true", only the initial gas volume field is entered, and the initial liquid volume is then determined based on that and the full tank volume that you enter. You must decide the ratio of gas to liquid (which also determines the relationship between pressure and flow and impacts how they change as conditions change during the transient simulation) There is no "correct" value to calculate and use for a given initial conditions, because these volumes in conjunction with the initial pressure basically determine how compressed the gas is. The basic equation for the gas law is PV=nrt and in HAMMER it is simplified to PV=K, where P = pressure, V = volume and K = constant.

    More details are in this article:

    Modeling Reference - Hydropneumatic Tanks

    If the gas in your tank is contained within a sealed bladder, choose "true" for "has bladder" and enter the desired preset / precharge pressure. Based on the preset pressure, tank size and initial conditions pressure, the initial volume of liquid and gas are calculated for you. The preset pressure is something you would need to decide on. A typical range may be between 5% and 80% of pipeline pressure, as per the above article. You can read more about using the preset pressure for a bladder tank here:

    Entering Hydropneumatic tank gas preset pressure based on assumed initial bladder volume

    The great thing about HAMMER is that you can set up multiple scenarios with different configurations (different ratio of gas to liquid volume, or different bladder preset pressures) and compare the transient results.

    --------------------------

    En español:

     

    Hola,

    La respuesta depende de la configuración del tanque. Suponiendo que utilice HAMMER V8i o CONNECT Edition:


    Cuando "tratar como unión" se establece en "falso", el volumen inicial del líquido y el volumen completo del tanque son valores que debe ingresar, y el volumen inicial del gas se obtiene como la diferencia entre los dos. Cuando "treat as junction" se establece en "true", solo se ingresa el campo inicial de volumen de gas, y luego se determina el volumen inicial de líquido basándose en eso y en el volumen completo del tanque que ingresa. Debe decidir la relación de gas a líquido (que también determina la relación entre presión y flujo e influye en cómo cambian a medida que cambian las condiciones durante la simulación transitoria) No hay un valor "correcto" para calcular y utilizar para unas condiciones iniciales dadas, ya que Estos volúmenes en conjunción con la presión inicial básicamente determinan cómo se comprime el gas. La ecuación básica para la ley de gas es PV = nrt y en HAMMER se simplifica a PV = K, donde P = presión, V = volumen y K = constante.

    Más detalles están en este artículo:

    Modeling Reference - Hydropneumatic Tanks


    Si el gas en su tanque está contenido dentro de una vejiga sellada, elija "true" para "tiene vejiga" e introduzca la presión de preajuste / precarga deseada. Con base en la presión preestablecida, el tamaño del tanque y las condiciones iniciales de presión, el volumen inicial de líquido y gas se calcula para usted. La presión preestablecida es algo que usted necesitaría decidir. Un intervalo típico puede estar entre el 5% y el 80% de la presión de la tubería, según el artículo anterior. Puede leer más acerca del uso de la presión preestablecida para un tanque de vejiga aquí:

    Entering Hydropneumatic tank gas preset pressure based on assumed initial bladder volume


    Lo bueno de HAMMER es que se pueden configurar múltiples escenarios con diferentes configuraciones (diferente proporción de gas a volumen de líquido, o diferentes presiones preselección de la vejiga) y comparar los resultados transitorios.


    Regards,

    Jesse Dringoli
    Technical Support Manager, OpenFlows
    Bentley Communities Site Administrator
    Bentley Systems, Inc.

    Answer Verified By: Sushma Choure 

Reply
  • En inglés:

    Hello,

    The answer depends on the tank configuration. Assuming you're using HAMMER V8i or CONNECT Edition:

    When "treat as junction" is set to "false", the initial liquid volume and full tank volume are values that you must enter, and the initial gas volume is derived as the difference between the two. When "treat as junction" is set to "true", only the initial gas volume field is entered, and the initial liquid volume is then determined based on that and the full tank volume that you enter. You must decide the ratio of gas to liquid (which also determines the relationship between pressure and flow and impacts how they change as conditions change during the transient simulation) There is no "correct" value to calculate and use for a given initial conditions, because these volumes in conjunction with the initial pressure basically determine how compressed the gas is. The basic equation for the gas law is PV=nrt and in HAMMER it is simplified to PV=K, where P = pressure, V = volume and K = constant.

    More details are in this article:

    Modeling Reference - Hydropneumatic Tanks

    If the gas in your tank is contained within a sealed bladder, choose "true" for "has bladder" and enter the desired preset / precharge pressure. Based on the preset pressure, tank size and initial conditions pressure, the initial volume of liquid and gas are calculated for you. The preset pressure is something you would need to decide on. A typical range may be between 5% and 80% of pipeline pressure, as per the above article. You can read more about using the preset pressure for a bladder tank here:

    Entering Hydropneumatic tank gas preset pressure based on assumed initial bladder volume

    The great thing about HAMMER is that you can set up multiple scenarios with different configurations (different ratio of gas to liquid volume, or different bladder preset pressures) and compare the transient results.

    --------------------------

    En español:

     

    Hola,

    La respuesta depende de la configuración del tanque. Suponiendo que utilice HAMMER V8i o CONNECT Edition:


    Cuando "tratar como unión" se establece en "falso", el volumen inicial del líquido y el volumen completo del tanque son valores que debe ingresar, y el volumen inicial del gas se obtiene como la diferencia entre los dos. Cuando "treat as junction" se establece en "true", solo se ingresa el campo inicial de volumen de gas, y luego se determina el volumen inicial de líquido basándose en eso y en el volumen completo del tanque que ingresa. Debe decidir la relación de gas a líquido (que también determina la relación entre presión y flujo e influye en cómo cambian a medida que cambian las condiciones durante la simulación transitoria) No hay un valor "correcto" para calcular y utilizar para unas condiciones iniciales dadas, ya que Estos volúmenes en conjunción con la presión inicial básicamente determinan cómo se comprime el gas. La ecuación básica para la ley de gas es PV = nrt y en HAMMER se simplifica a PV = K, donde P = presión, V = volumen y K = constante.

    Más detalles están en este artículo:

    Modeling Reference - Hydropneumatic Tanks


    Si el gas en su tanque está contenido dentro de una vejiga sellada, elija "true" para "tiene vejiga" e introduzca la presión de preajuste / precarga deseada. Con base en la presión preestablecida, el tamaño del tanque y las condiciones iniciales de presión, el volumen inicial de líquido y gas se calcula para usted. La presión preestablecida es algo que usted necesitaría decidir. Un intervalo típico puede estar entre el 5% y el 80% de la presión de la tubería, según el artículo anterior. Puede leer más acerca del uso de la presión preestablecida para un tanque de vejiga aquí:

    Entering Hydropneumatic tank gas preset pressure based on assumed initial bladder volume


    Lo bueno de HAMMER es que se pueden configurar múltiples escenarios con diferentes configuraciones (diferente proporción de gas a volumen de líquido, o diferentes presiones preselección de la vejiga) y comparar los resultados transitorios.


    Regards,

    Jesse Dringoli
    Technical Support Manager, OpenFlows
    Bentley Communities Site Administrator
    Bentley Systems, Inc.

    Answer Verified By: Sushma Choure 

Children
No Data