18. Why does the wind load appear that is not being applied to the model in AutoPIPE?


Applies To
Product(s):AutoPIPE,
Version(s):ALL
Environment: N/A
Area: Load
Original Author:Bentley Technical Support Group

Problem:

Why does the wind load appear that is not being applied to the model in AutoPIPE?

Solution: 

Confirm the following:

A. On the Wind dialog screen:

1. The piping where wind is being applied is above this user input value (default = 0.00 ft). any piping below this vertical location will assumed to be buried in soil or under water. 

2. Wind shape factor is greater than 0.000 (default = 1.0)

3. Check box is enabled if all segments are exposed to wind, otherwise confirm segments applied to wind on the Segment Tab of the Input grids; "Wind" column.

4. There is at least one Wind load case being applied to the model.

B. On the Wind Profile dialog screen:

1. Basic Wind Speed is greater than 0.000

2. Importance Factor is greater than 0.000 (default = 1.000)

3. Wind direction is specified as needed.

C. Static Analysis Load case settings:

See Also

Modeling "Wind" - Load Case

Bentley AutoPIPE