To Create Missing SIGHT_GLASS Class data in OpenPlant Modeler


  
 Applies To 
  
 Product(s):OpenPlant Modeler
 Version(s):08.11.09.XXX
 Environment: Windows 7 (64 bit)
 Area: OpenPlant Specification Generator
 Subarea: -
 Original Author:Rahul Kumar, Bentley Product Advantage Group
  

Overview

To create missing class data by converting it through specification generator. 

Problem Description

With the use of Specification generator, under catalog editor, component table does not includes few classes which are present inside the default schema. User wanted to get it added inside the Catalog Editor. Below steps describes the process of adding it in table. This is the case for Metric Environment. For Mixed Metric Environment conversion process will give different output & there are on ongoing issues with it. User need to follow below steps on realizing the catalog information in specgen. 

Steps to Resolve

  1. Launch Specification Generator and select working unit as Imperial ( As it has Sight Glass Entries).

  2. Go to File -> Unit Converter. See image below.



  3. From “Unit Converter Utility”, set the Target Unit to desired Project unit, say Metric here.



  4. Select Source Catalog, say by navigation Non Standard Imperial catalog. Rename it to any logical name, say NS_SIGHT_GLASS_Imperial below. By doing so it will convert the file to destination catalog folder without issue. And chose destination directory to save the converted catalog. 









  5. This will create a new catalog to destination folder.

  6. Open new catalog created after conversion. Check if SIGHT Glass is present.

  7. See image below: 



  8. Rename it as SIGHT_GLASS and copy table. See image below.



  9. Open desired catalog to past the table. See image below.



  10. It will ask to copy whole Structure and Data. Click on OK with settings shown in below image.



  11. Also include table fr SIGHT_GLASS. See image below.



  12. Save and Close both catalog.

  13. Also open Catalog Editor and verify the data for SIGHT_GLASS. See image below.



  14. Launch OpenPlant Modeler and place Sight Glass to verify. See image below.

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

See Also

communities.bentley.com/.../13028.openplant-specification-generator

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!