OpenPlant Isometrics Manager generates incorrect Symbols for Multi Way Valves when generated through OpenPlant Modeler
Multi Way valve Class has been used to configure two types of valves, namely “Three way Inline Valve” & “Three Way Rotated Valve” in OpenPlant Modeler. Three Way Valve Supposed to be with two different IP (Intersection point ) and not to be configured like Tee type geometry. See Image below for both the configuration:
Three way Inline ValveThree Way Rotated Valve
It can be done in 3 steps:
A. To Define Classes in Schema
B. To Replace ipscript.txt file.
C. To add Symbolsize.def file & custom graphics in cel file.
RULE: this.GetClass().Name = THREE_WAY_ROT_VALVE,THREE_WAY_INLINE_VALVE
A = Scale (V2, -1 * this.DESIGN_LENGTH_CENTER_TO_BRANCH_END)
IP1 = Add (P2, A)
A = Scale (V3, -1 * this.DESIGN_LENGTH_CENTER_TO_BRANCH_END)
IP2 = Add (P3, A)
SYS 3WAYM_3T 3 2 4 # 3 CP, 2 IP, 4 segments (pipe return bottom/side outlet)
SEGMENT 1 5
SEGMENT 2 4
SEGMENT 3 5
SEGMENT 4 5
DEF 3WAYM_3T 3WAYM_3T
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12647.modifying-symbols
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!