To Open Schema in Class Editor


Applies To 
Product(s): Bentley Class Editor
Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)
Environment: Windows 7/8.1/10 (64 bit)
Area: Class Editor
Subarea: Schema Opening
Original Author: Deepak Singh, Bentley Product Advantage Group

Overview

To Open Desired schema through Bentley Class Editor..

Problem Description

When opening OpenPlant_3D.01.07. ecschema (SS6) software shows missing reference as Integratedstructuralmodel.04.00. ecschema & Designsync.01.01. ecschema.

The OpenPlant_3D ecschema contains the data model properties and is referenced by all OpenPlant Modeler schema

Steps to Resolve

  1. Using OpenPlant Project Administrator, launch Bentley Class Editor.
    Note - User may also  launch Bentley Class Editor from All programs/Apps>Bentley>Class Editor.

  2. The interface will be shown as below.




  3. Click on Open. User may directly use folder icon OR go through File>Open.





  4. Select desired project, from following location select OpenPlant_3D ecschema.

    C:\ProgramData\Bentley\OpenPlantModelerV8i\WorkSpace\Projects\OPModeler_Imperial\DataSet\Schemas



  5. Clicking on Open will ask for locate missing reference OpenPlant schema file as shown.



  6. From below mentioned location locate above mentioned missing reference schema file.

    C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas

  7. Select OpenPlant schema and click on Open.



  8. Again, it will ask to locate missing reference of Integratedstructuralmodel ecschema.

  9. From the same mentioned location select Integratedstructuralmodel ecschema and open.



  10. In the last, it will ask for locate missing reference of DesignSync ecschema as shown.



  11. From the same mentioned location, select the missing DesignSync schema and click open.



  12. This will open OpenPlant_3D schema successfully.



  13. Notice the message in bottom pane of class editor OpenPlant_3D opened successfully.

Locate Reference Schema Automatically

  1. It is always a good practice to set location for picking reference schemas.

  2. From class editor interface. Click on Tools > Options.



  3. In Options window, add the following path from mentioned location.

    For OPModeler schema:C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas

    For Project Schema:
    C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Imperial\DataSet\Schemas

  4. After adding the path for missing reference, click on Apply and OK.

Supplementing of Schemas

  1. Right click on OpenPlant_3D and select Supplement Schema as shown below.



  2. Click on Add, to specify supplemental schemas as shown below



  3. Select your desired supplemental schemas & click on Open. See image below


  4. Once desired supplemental schemas is selected it will reflect in Specify Supplemental Schemas window as shown below.



  5. Click on OK to proceed, notice OpenPlant_3D is supplemented successfully as shown below.

Still a Problem?

If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. 

See Video

Check Similar Video for above described situation.

See Also

communities.bentley.com/.../19903.locate-missing-reference-schema-files-message-while-loading-schema-in-class-editor

 Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!