Fouling point placement

I have designed one depot layout. I have placed turnouts. Now i want place fouling points.

How to calculate fouling mark at 1 in 7, 190 R turnout.

I got one calculation while google

Fouling point 3.816m = Width of train (3.312m) + Dynamic throw (0.200m) + Central throw (0.142m) + 
End throw (0.162m)

What is dynamic throw here.

And after calculation how to place automatically at all turnouts. If we place there is it possible to generate coordinates for fouling point..?

Parents
  • I guess you need shunt limits:

    This is example of the txt file: 

    #radius	curvature adjustment
    100	0.360
    120	0.300
    140	0.257
    160	0.225
    180	0.200
    200	0.180
    220	0.164
    240	0.150
    260	0.138
    280	0.129
    300	0.120
    320	0.113
    340	0.106
    360	0.100
    380	0.095
    400	0.090
    420	0.086
    440	0.082
    460	0.078
    480	0.075
    500	0.072
    1000	0.036
    1500	0.024
    2000	0.018
    10000	0.004

    (BRT V08.11.07.685, on MS, SS 2)

Reply
  • I guess you need shunt limits:

    This is example of the txt file: 

    #radius	curvature adjustment
    100	0.360
    120	0.300
    140	0.257
    160	0.225
    180	0.200
    200	0.180
    220	0.164
    240	0.150
    260	0.138
    280	0.129
    300	0.120
    320	0.113
    340	0.106
    360	0.100
    380	0.095
    400	0.090
    420	0.086
    440	0.082
    460	0.078
    480	0.075
    500	0.072
    1000	0.036
    1500	0.024
    2000	0.018
    10000	0.004

    (BRT V08.11.07.685, on MS, SS 2)

Children