Applies To | |||
Product(s): | STAAD.Pro | ||
Version(s): | All | ||
Environment: | N/A | ||
Area: | Modeling Solutions | ||
Subarea: | Loading | ||
Original Author: | Bentley Technical Support Group | ||
How to eliminate the following warning that is reported in the .anl file when floor load command is used?
"**WARNING** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may have to break up the FLOOR/ONEWAY LOAD into multiple commands. For details please refer to Technical Reference Manual Section 5.32.4 Note 6."
Answer : You may type in the SET PRINT 5 command in the input file using the STAAD editor ( Edit > Edit Input Command File ), as shown next and it should remove the warning due to floor load
STAAD SPACE EXAMPLE PROBLEM
…
END JOB INFORMATION
SET PRINT 5
UNIT FEET KIP
JOINT COORDINATES