Problem Description: When right-clicking on a horizontal alignment, the "check integrity" command is grayed out and unavailable.Solution: Horizontal and Vertical Elements Add-In must be toggled on in Tools > Application Add-Ins for this command to be available within the product.
The Generate Grade Contour command computes and displays a path that traverses a triangulated Digital Terrain Model (DTM), ascending as steeply as possible without exceeding a specified maximum slope. The input for the command is an initial point, an initial direction, and a maximum allowable slope. The computed path terminates at the boundary of the DTM or at one of its local maxima. The path is further constrained not…
Go to C:\Program Files\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config\appl and edit the WaterCAD.cfg file. The last line of the file says, “MS_LIBRARY_PATH < $(MS_WATERCAD_ROOTDIR)”. Change the < sign to a > sign and the issue will be resolved.
This issue occurs when regenerating the surface with the Create Surface command with “Empty Design Surface” toggled on. This empties the design surface and recreates the components, features, etc of the surface with new GUID numbers. When this occurs the cross section no longer has its intelligence and it cannot be updated. The workflow should be to turn off the “Empty Design Surface” toggle and select “Modify…
Run the Copy Preferences command (Tools > Application Add-in > Copy Preferences) to get these file types for import into their *.XIN file. First, open the *.XIN file that is desired for importing. Next, go to Tools > Copy Preferences. Then, browse for the Source Preference File located in the following directory: C:\Program Files\Bentley\InRoads Group V8.11\Sample Data\Survey\survey.xin. After that, select “SurveyIMPEXP…