Prostructures (Select series 5) and Navisworks 2012/13 not compatible?

Before installing Select series 5, Navisworks (2012 and 2013) read Prostructures objects without problem. Now I can't view those items at all.

What things should I be trying to get this working again?

Parents Reply
  • Navisworks caches the dwg file to a nwc file and then uses only the nwc file. You must remove the nwc file.

    Then Navisworks uses the prostructures.dbx to open the dwg and to cache it.

    I have Navisworks 13 but I forced it to use the 18.2 dbx Loader. Dwg Loader Version is set to 2012.

    Can be set with Global options.

    Reason is:

    AutoCAD 2013 needs a Service Pack 1.1 to load ProStructures Dwgs.

    Same for the RealDwg 2013 as I can see with Bentley MicroStation SS3.

    I guess a Service Pack 1.1 for NavisWorks 2013 will be offered by Autodesk later.

    The AutoCAD object dbx entry for Pro_Stahl_App points to the Navisworks folder.

    I have the AutoCAD objectenabler (objectdbx) key and the Navisworks objectdbx key set up.

    Please look at my screenshots and try to reproduce.