“BETA VALUE OF 0.19 FALLS OUTSIDE THE VALID RANGE OF 0.2 - 1.0 FOR SIMPLE JOINTS (Cl. 4.3.1)”


  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Steel Design
 Subarea: API 2A-WSD 21st Edition
 Original Author:Bentley Technical Support Group
  

What is the meaning of this warning message – “BETA VALUE OF  0.19 FALLS OUTSIDE THE VALID RANGE OF 0.2 - 1.0 FOR SIMPLE JOINTS (Cl. 4.3.1)”?

Clause 4.3.1 defines the ranges for beta, gamma and theta for joint check. If the calculated values fall outside the range of the prescribed values, the API implementation will float the corresponding warning message. In this case, the the value of beta is calculated as 0.19 which is less than the prescribed minimum value of 0.2.