Definitions Of Terms: |
|
|
|
|
|
All
forces in units 'kN' and 'mm' |
|
|
|
All reinforcement details like area, spacing in 'mm' |
|
Neutral axis angle for resultant design moment is with respect to local major axis. |
|
|
|
|
1 |
Aj |
= |
Effective cross-sectional area within a joint in a plane parallel to plane of reinforcement generating shear in the joint in 'sqmm' |
2 |
Ast Req |
= |
Area of reinforcement required in Beam at section Considered in 'sqmm' |
3 |
Ast Pro |
= |
Area of reinforcement Provided in Beam at section Considered in 'sqmm' |
4 |
B |
= |
Width of column in 'mm' |
5 |
B' |
= |
Effective width of beam along B / column width in 'mm' |
6 |
D |
= |
Depth / diameter of column in 'mm' |
7 |
D' |
= |
Effective width of beam along D / column width in 'mm' |
8 |
fck |
= |
Specified strength of concrete in 'N/sqmm' |
9 |
fy |
= |
Specified yield strength of reinforcement in 'N/sqmm' |
10 |
Mu |
= |
Moment in Beam at Section Considered in 'kNm |
11 |
Mu Cap |
= |
Moment Capacity of Beam at Section Considered
in 'kNm' |
12 |
Mt |
= |
Equivalent Bending moment due to torsion at Section Considered in
'kNm' |
13 |
Mnb |
= |
Flexure Capacity for Beam in 'kNm' |
14 |
Mnc |
= |
Flexure Capacity for Column in 'kNm' |
15 |
Mncd |
= |
Flexure Capacity of Columns along D in 'kNm' |
16 |
Mncb |
= |
Flexure Capacity of Columns along B in 'kNm' |
17 |
Pu |
= |
Axial force in Column corresponding to Flexural
capacity of Column along D or along B in 'kN' |
18 |
V-Reinf |
= |
Design shear demand from beam reinforcment in 'kN' |
19 |
Vuy |
= |
Shear induced due to beam capacity along D of column in 'kN' |
20 |
Vux |
= |
Shear induced due to beam capacity along B of column in 'kN' |
21 |
Vj |
= |
Shear Force acting at the joint in 'kN' |
22 |
Vn' |
= |
Nominal shear strength in 'kN' |
Code References: |
|
|
|
|
ACI 318M - 11 |
|
|
|
|
Sr.No |
Element |
|
Clause / table |
1 |
Minimum Flexural Strength of Columns |
: |
21.6.2.2 |
2 |
Shear Check at Column Joint |
: |
21.7.4.1 |
3 |
Shear Strength of Column |
: |
21.3.3 & 21.5.4 |
|
Column Below |
Column Above |
Member Number |
101 |
111 |
Concrete Grade (fck) (Cylindrical) |
C25 |
C25 |
Steel Grade (fyk) |
Fy420 |
Fy420 |
Column Size (mm) |
700 X 700 |
700 X 700 |
|
Check At Beam-Column Joints: |
|
|
|
|
1. Flexure Strength Of Joint: |
Moment Capacity Calculations for Beam |
Effective Moment for Beam |
|
Along D |
Along B |
|
Left |
Right |
Left |
Right |
Top (kNm) |
522.35 |
473.42 |
601.88 |
- |
Bottom (kNm) |
276.01 |
242.53 |
436.47 |
- |
Mnb (kNm) |
MAX((Left Bottom + Right Top), (Left Top + Right Bottom)) |
MAX((Left Top + Right Bottom), (Right Top + Left Bottom)) |
764.88 |
601.88 |
|
Check for Column Flexural Capacity |
|
Along D |
Along B |
Critical Load Combination Top |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Top (kN) |
4969.66 |
4969.66 |
Mnc Top (kNm) |
787.86 |
787.86 |
Critical Load Combination Bot |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Bot (kN) |
5979.23 |
5979.23 |
Mnc Bottom (kNm) |
545.78 |
545.78 |
Mnc (kNm) |
1333.64 |
1333.64 |
>= 1.2 x Mnb, Hence OK |
>= 1.2 x Mnb, Hence OK |
|
2. Shear Strength of Joint: |
Check for Column Flexural Capacity |
|
Along D |
Along B |
Critical Load Combination Top |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Top (kN) |
3180.2 |
3180.2 |
Mnc Top (kNm) |
956.49 |
956.49 |
Critical Load Combination Bot |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
[7] : 4 (LOAD 1: LOAD CASE 1) +(LOAD 2: LOAD CASE 2) -1.01 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Bot (kN) |
4790.37 |
4790.37 |
Mnc Bottom (kNm) |
809.31 |
809.31 |
Mnc (kNm) |
1765.81 |
1765.81 |
>= 1.2 x Mnb, Hence OK |
>= 1.2 x Mnb, Hence OK |
|
2. Shear Strength of Joint: |
Check for Column Flexural Capacity |
|
Along D |
Along B |
Critical Load Combination Top |
[25] : 0.9 (LOAD 1: LOAD CASE 1) -0.42 (LOAD 3: LOAD CASE 3 EQ-X) +1.4 (LOAD 4: LOAD CASE 4 EQ-Y) |
[25] : 0.9 (LOAD 1: LOAD CASE 1) -0.42 (LOAD 3: LOAD CASE 3 EQ-X) +1.4 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Top (kN) |
254.4 |
254.4 |
Mnc Top (kNm) |
1291.38 |
1291.38 |
Critical Load Combination Bot |
[25] : 0.9 (LOAD 1: LOAD CASE 1) -0.42 (LOAD 3: LOAD CASE 3 EQ-X) +1.4 (LOAD 4: LOAD CASE 4 EQ-Y) |
[25] : 0.9 (LOAD 1: LOAD CASE 1) -0.42 (LOAD 3: LOAD CASE 3 EQ-X) +1.4 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Bot (kN) |
479.33 |
479.33 |
Mnc Bottom (kNm) |
855.96 |
855.96 |
Mnc (kNm) |
2147.33 |
2147.33 |
>= 1.2 x Mnb, Hence OK |
>= 1.2 x Mnb, Hence OK |
|
2. Shear Strength of Joint: |
Check for Column Flexural Capacity |
|
Along D |
Along B |
Critical Load Combination Top |
- |
- |
Pu Top (kN) |
- |
- |
Mnc Top (kNm) |
- |
- |
Critical Load Combination Bot |
[25] : 0.9 (LOAD 1: LOAD CASE 1) -0.42 (LOAD 3: LOAD CASE 3 EQ-X) +1.4 (LOAD 4: LOAD CASE 4 EQ-Y) |
[25] : 0.9 (LOAD 1: LOAD CASE 1) -0.42 (LOAD 3: LOAD CASE 3 EQ-X) +1.4 (LOAD 4: LOAD CASE 4 EQ-Y) |
Pu Bot (kN) |
208.08 |
208.08 |
Mnc Bottom (kNm) |
1281.24 |
1281.24 |
Mnc (kNm) |
1281.24 |
1281.24 |
>= 1.2 x Mnb, Hence OK |
>= 1.2 x Mnb, Hence OK |
|
2. Shear Strength of Joint: |