Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Licensing, Cloud and Web Services
  • Welcome to Bentley Communities
  • Bentley's Communities
  • Licensing, Cloud and Web Services
  • Cancel
Licensing, Cloud and Web Services
Licensing, Cloud and Web Services Wiki Troubleshooting Product Activation for XM and Higher
    • Sign In
    • Eastern Europe Continuity Plan
    • Guest Accounts - Review Access
    • +Web Services
    • +SES Activation
    • +CONNECTION Client
    • +CONNECT Advisor
    • +Federated Identity
    • -SELECTserver based Activation
      • Understanding the (Legacy) SELECTserver Workflow
      • +Deployed SELECTserver Application Usage TechNotes and FAQs
      • Activating Against SELECTserver OnLine (a Bentley hosted server)[TN]
      • Activating Applications Using SELECTserver Based Licensing as a non-SELECT User
      • Activating Non-Licensed Trial Mode Software
      • Activation of Client Side Products and Registry Basics
      • Client Check In and Out Instructions for XM and Higher [TN]
      • Importing a Checked Out License (XML file) for XM and Higher [TN]
      • Disconnected Mode [FAQ]
      • Generating a License Debug Log
      • +License Management Tool
      • Product Activation [FAQ]
      • Product Activation Modes of Behavior
      • Renewal Process for All Licensing
      • Server does not support this Activation Key
      • Troubleshooting Product Activation for XM and Higher
      • +SELECTserver TechNotes and FAQs
      • Where do I find my Activation Key?
      • Prevent unauthorized SELECTserver Activation Key based Usage
      • Stopping SELECTserver Activation Key based Usage
    • +Pre-SELECTserver Based Activation
    • +Product-Specific Licensing
    • Understanding why you received a TL Invoice
    • Working from Home using Bentley Licensing
    • +Licensing Workflow
    • How to leave a Product Review
    • +Serviços ProjectWise 365
    • About Bentley Trust Licensing
    • Customer Number, Account Number, Entitlements, Users
    • How to delete Bentley account and all related data
    • Support for non-Bentley technologies utilized by Bentley products
    • Support for V8i applications after December 31st, 2021
    • +Support Homepage - Localized
    • What you need to know/request when consolidating Accounts

    Troubleshooting Product Activation for XM and Higher

       
      Applies To 
       
      Product(s): All
      Version(s): XM and higher
      Environment:  N/A
      Area:  N/A
      Subarea:  N/A
      Original Author: Bentley Technical Support Group
       

    Overview

    Product Activation is the act of authenticating a product for entitled use.  If you need assistance activating, please see Product Activation.  If you have any trouble activating, please proceed.

    If at any point during the below troubleshooting steps you find you need further assistance, please feel free to post to the Community Forum.

     

    Troubleshooting

    1. From the client workstation where the software is installed, open the License Management Tool.

        From within the License Management Tool, go to the "Tools" menu and select "Options."  
       

        Confirm the server name:

    • SELECTserver Online: selectserver.bentley.com -- Make sure Bentley has two e's!
    • Home Use SELECTserver: selectserver-home.bentley.com -- The -home is sometimes missing.
    • Deployed SELECTserver: In most cases, the server name should match the hostname for the server where SELECTserver is installed on your network. Check with your site administrator to make sure you're using the correct server name.

         Confirm the site activation key:

    • Given the length of the site activation key, we recommend copying and pasting the site activation key.
    • Make sure there are no leading or trailing spaces. Copying and pasting sometimes results in an extra space at the end.
    • The site activation key is case sensitive. All letters should be CAPITALIZED.
    • Anything which looks like an 'O' is a zero (0). Our keys do not use the letter O.

         Click "Test Connection". You should get a message stating “SELECT Server and Activation key verified.
       

        You could also get the following messages:

    • “An error has occurred while attempting to verify the server and activation key” -- This means the server specified could not be reached.
      • Try enabling the “Use HTTPS (SSL)” setting. Your network may require it.
      • There may be a firewall or proxy server preventing communication with the server. Review our information on connecting to Bentley servers through firewall or proxy servers.
      • See the next step for information on verifying your connection to your SELECTserver.
    • “Server does not support this activation key.” -- This means a connection to the server specified was able to be made, but the Site Activation Key is incorrect. 
      • Return to the previous step to confirm Server Name and Site Activation Key.

    2. Verify that you are able to connect with your SELECTserver.

    • SELECTserver Online (Hosted)

      • Are you able to access https://selectserver.bentley.com?
        • Yes, in Internet Explorer: This indicates you are connected to the internet and your settings are allowing communication with Bentley's server. Bentley's License Management Tool uses Internet Explorer's internet settings to communicate with our server.
        • Yes, in another browser: This indicates you are connected to the internet, but your Internet Explorer's internet settings may be preventing communication with our server. Try in Internet Explorer.
        • No, not at all: There is a problem with your internet connection or firewall on that computer. Please consult with your internal support to resolve this issue.
    • Deployed SELECTserver (Local)

      • Go to Start > Run. Enter 'cmd' and click 'Okay'. This will open a command prompt. In this new window, enter 'ping <servername>' where <servername> is the name of your SELECTserver which you have set in your License Management Tool.
      • If you get a response, you're able to communicate with your server.
      • If you do not get a response, try entering the IP address instead to rule out a DNS issue. Otherwise, check with your network administrator to resolve the connectivity issue.

    3. Verify your license is up to date on your SELECTserver Administration Site.

    • Go to your SELECTserver Administration Site
      • SELECTserver Online (Hosted): http://selectserver.bentley.com/bss/admin/
      • Deployed SELECTserver (Local): http://yourservername/bss/admin/ where 'yourservername' is the name of the server where the SELECTserver software is installed.
    • Go to 'View License File' under the 'License Management' menu.
      • Verify that a license is listed for the product you are trying to activate.
      • Verify that the expiration date for that license is valid (any date after today).

    4. From within the License Management Tool, go to the "Tools" menu and select "Send Logs Now."  This forces the workstation to re-establish connection with the server. Repeat up to three times.

    5. If your activation completes without error but you are still asked to activate when opening the product, try to run the License Management Tool as an Administrator (Right click > Run as Administrator) You may not have the proper permissions to record the "check-out" to the registry. Otherwise contact the Administrator of the machine.

    6. Try to activate on another machine.  If another machine can establish a connection, investigate any potential differences between the two computers.

    7. Open Internet Explorer, and ensure that Offline Mode is unchecked in the File menu. Because the License Management Tool relies upon Internet Explorer, it cannot connect to the Internet if the browser is configured for Offline Mode.

    Again, if you need further assistance, please feel free to contact Product Activation support by posting to the SELECTserver and Product Activation Forum.

    See Also

    Troubleshoot different Licensing issues:
    http://communities.bentley.com/products/licensing/w/licensing__wiki/2779.aspx 

    • activation
    • PondPack
    • StormCAD
    • proxy
    • SewerGEMS
    • error
    • SewerCAD
    • not able to connect
    • WaterGEMS
    • activation key
    • Troubleshooting
    • CivilStorm
    • SELECT Server
    • WaterCAD
    • Lincensing XM
    • Share
    • History
    • More
    • Cancel
    • Melissa Koval Created by Melissa Koval
    • When: Mon, Feb 27 2012 1:51 PM
    • Brian D., User Success Support Last revision by Bentley Colleague Brian D., User Success Support
    • When: Wed, May 19 2021 4:41 PM
    • Revisions: 23
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies