Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Shane Regan
Likes
Profile
Activity
Communities
Friends
Likes
Achievements
Blog Posts
Questions
More
Cancel
CAD Model Design - Gap Between Roof And Walls
Duncan Brown
Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When modelling a roof in Hevacomp a space can sometimes appear between the roof…
over 6 years ago
Hevacomp
Hevacomp Wiki
CAD Model Design - Elevating roofs using Roof Points
Krishnendu Paul
Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When designing a roof for a Design Database project, you may not be able to elevate…
over 1 year ago
Hevacomp
Hevacomp Wiki
CAD Model Design - Deleting roofs
Duncan Brown
Product(s): Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Even though there isn't a method from with Design Database to delete roof drawings, it is…
over 6 years ago
Hevacomp
Hevacomp Wiki
CAD Model Design - Considering split level floors?
Duncan Brown
Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview There may be times when you wish to consider a split level floor in a project…
over 6 years ago
Hevacomp
Hevacomp Wiki
CAD Model Design - Changing Floor Heights
Duncan Brown
Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on how to change Floor heights in Design Database…
over 6 years ago
Hevacomp
Hevacomp Wiki
CAD Model Design - Adding different roof section types
Duncan Brown
Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The roof construction fabric can be changed as you are adding roof sections. Method…
over 6 years ago
Hevacomp
Hevacomp Wiki
CAD Model Design - Adding atrium style spaces to a project
Duncan Brown
Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on modeling Atrium type spaces in Design Database…
over 6 years ago
Hevacomp
Hevacomp Wiki
CAD mode and Room data mode
Duncan Brown
Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Describing the difference between CAD and Room Data mode. Method There are two…
over 5 years ago
Hevacomp
Hevacomp Wiki
Why Do Lumen Reports Show NA
Duncan Brown
Product(s): Hevacomp Nimbus Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Under some circumstances, it is possible to receive N/A when choosing a luminaire solution…
over 6 years ago
Hevacomp
Hevacomp Wiki
Adding wall mounted luminaires
Duncan Brown
Product(s): Hevacomp Nimbus Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The Nimbus database contains a large number of manufacturers luminaires. Some of these luminaires…
over 6 years ago
Hevacomp
Hevacomp Wiki
Underground cables appear to be undersized
Duncan Brown
Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Underground cables appear to be undersized when the calculation is run Solution You should…
over 6 years ago
Hevacomp
Hevacomp Wiki
Unable to open Security Copy
Duncan Brown
Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When trying to open a Hevacomp Connect project you may come across the following message…
over 6 years ago
Hevacomp
Hevacomp Wiki
The I²t is not what I expected
Duncan Brown
Product(s): Hevacomp Electrical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem During the Connect calculation, I²t is derived for checking short circuit faults…
over 6 years ago
Hevacomp
Hevacomp Wiki
Short circuit fault current and current limiting devices
Duncan Brown
Product(s): Hevacomp Electrical Designer - Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem As part of the cable sizing calculation, short circuit fault currents…
over 5 years ago
Hevacomp
Hevacomp Wiki
Setting the project title in Connect
Duncan Brown
Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem The project title is not being set correctly. Solution The reports won't reflect a new…
over 6 years ago
Hevacomp
Hevacomp Wiki
>