  • CAD Model Design - Gap Between Roof And Walls

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When modelling a roof in Hevacomp a space can sometimes appear between the roof…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD Model Design - Elevating roofs using Roof Points

    Krishnendu Paul
    Krishnendu Paul
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When designing a roof for a Design Database project, you may not be able to elevate…
    • over 1 year ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD Model Design - Deleting roofs

    Duncan Brown
    Duncan Brown
    Product(s): Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Even though there isn't a method from with Design Database to delete roof drawings, it is…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD Model Design - Considering split level floors?

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview There may be times when you wish to consider a split level floor in a project…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD Model Design - Changing Floor Heights

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on how to change Floor heights in Design Database…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD Model Design - Adding different roof section types

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The roof construction fabric can be changed as you are adding roof sections. Method…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD Model Design - Adding atrium style spaces to a project

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on modeling Atrium type spaces in Design Database…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • CAD mode and Room data mode

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Describing the difference between CAD and Room Data mode. Method There are two…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Why Do Lumen Reports Show NA

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Nimbus Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Under some circumstances, it is possible to receive N/A when choosing a luminaire solution…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Adding wall mounted luminaires

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Nimbus Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The Nimbus database contains a large number of manufacturers luminaires. Some of these luminaires…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Underground cables appear to be undersized

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Underground cables appear to be undersized when the calculation is run Solution You should…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Unable to open Security Copy

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When trying to open a Hevacomp Connect project you may come across the following message…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • The I²t is not what I expected

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Electrical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem During the Connect calculation, I²t is derived for checking short circuit faults…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Short circuit fault current and current limiting devices

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Electrical Designer - Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem As part of the cable sizing calculation, short circuit fault currents…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Setting the project title in Connect

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Connect Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem The project title is not being set correctly. Solution The reports won't reflect a new…
    • over 6 years ago
    • Hevacomp
    • Hevacomp Wiki
>
Communities
  • Home
  • Getting Started
  • Community Central
  • Products
  • Support
  • Secure File Upload
  • Feedback
Support and Services
  • Home
  • Product Support
  • Downloads
  • Subscription Services Portal
Training and Learning
  • Home
  • About Bentley Institute
  • My Learning History
  • Reference Books
Social Media
  •    LinkedIn
  •    Facebook
  •    Twitter
  •    YouTube
  •    RSS Feed
  •    Email

© 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies