<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>serraric's Activities</title><link>https://communities.bentley.com/members/126f2426_2d00_0fed_2d00_4762_2d00_816b_2d00_9897157cf928</link><description>serraric's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Grids and Floor elevation datums disappear after refresh annotation button selected</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/176805/grids-and-floor-elevation-datums-disappear-after-refresh-annotation-button-selected</link><pubDate>Tue, 19 Mar 2019 00:26:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8efd69cc-2259-49c8-818b-f269a13e4ce9</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;I am hoping you can help us out with this issue regarding refreshing annotations in a drawing model file.&amp;nbsp; As Projectwise Administrator, when I do a refresh annotations, it take about 20 secs and refresh is successful.&amp;nbsp; For anybody else doing a refresh, the floor datums and grid completely disappears.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I am wondering if this is a user access issue in projectwise to a particular folder?&amp;nbsp; I have all members under &amp;ldquo;Team Members&amp;rdquo; user group and when they do a refresh everything disappears. &amp;nbsp;&amp;nbsp;I then added one of those members under &amp;lsquo;ProjectWise Administrator&amp;rdquo; user group and the refresh was successful.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;What system file controls the Refresh Annotation tool?&amp;nbsp; Did I lock the entire team out of it?&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;This is impacting all disciplines and was hoping you can look into this for us, would be greatly appreciated.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;ABD V8i - ProjectWise Connect edition&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/446x85/__key/communityserver-discussions-components-files/5917/6787.pastedimage1552954942866v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;NM_dataset&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can&amp;#39;t modiy Door Architrave width and door symbols are incorrect</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/176569/can-t-modiy-door-architrave-width-and-door-symbols-are-incorrect</link><pubDate>Wed, 13 Mar 2019 19:01:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:11682c14-a3bc-42ef-a158-1aaa51366fb5</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;2 Door problems:&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;1. I am having issues modify the Door Architrave Width, the purpose of this is to push the door frame out so we can take a proper dimension for the door rough opening.&lt;/p&gt;
&lt;p&gt;&lt;img height="275" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/3716.pastedimage1552503612252v2.png" width="530" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;2. How can we fix the door symbol and mirror it?&lt;/p&gt;
&lt;p&gt;&lt;img height="312" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/5618.pastedimage1552503659854v3.png" width="487" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;ABD V8i&lt;/p&gt;
&lt;p&gt;&lt;img height="85" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/8244.pastedimage1552503401467v1.png" width="446" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;NM_dataset&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to lock Section Call Outs after activating their &amp;quot;marker&amp;quot; on the Sheet?</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/153441/how-to-lock-section-call-outs-after-activating-their-marker-on-the-sheet</link><pubDate>Mon, 30 Apr 2018 20:04:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3ab58d92-3295-4459-aea9-8ed77d02c922</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;Using AECOsim SS6 (not Connect)&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;We are having issues with people opening the composition and accidently changing the crop region in the saved view (for whatever reason).&amp;nbsp; This happens every so often inadvertently.&amp;nbsp;&amp;nbsp; The problem is that we have multiple Sheets where its section call out has moved from its original location due to someone messing with the Section composition file.&lt;/p&gt;
&lt;p&gt;Is there a way to lock the location of the Section Call out after it has been activated from its marker?&amp;nbsp; So that if it composition is ever affected again, we don&amp;#39;t have to go and fix 60 drawings?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks and let me know!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Navisworks Exporter Keyin batchnwdout</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/169094/navisworks-exporter-keyin-batchnwdout</link><pubDate>Wed, 10 Oct 2018 03:39:36 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7318e4df-c79a-4c78-be64-fb20a5092a8e</guid><dc:creator>Simon Biddle</dc:creator><description>&lt;p&gt;I&amp;#39;m exporting our dgn files out to navisworks via the Exporter Plugin that is an mdl file through AECOsim.&lt;/p&gt;
&lt;p&gt;There is a keying available from the mdl batchnwdout that can take in a file path and file name but I can&amp;#39;t seem to get a a variable like $(_DGNFILE) to work. If I don&amp;#39;t specify a path it outputs the nwd file to the directory the file being exported is in.&lt;/p&gt;
&lt;p&gt;I&amp;#39;m just wondering if anyone has any experience batch running nwd files out of AECOsim.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;FYI&lt;/p&gt;
&lt;p&gt;I had been running the batch utility out of Navisworks but running them from AECOsim is at least 10x faster. I was also running into memory issues using Navisworks for exporting.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Printing error in v8 SS5</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/102094/printing-error-in-v8-ss5</link><pubDate>Fri, 24 Oct 2014 10:34:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d1e6e857-36d7-4418-8ddc-93ac4d9ba652</guid><dc:creator>Graham Collingridge</dc:creator><description>&lt;p&gt;When PDFing a sheet file in v8 SS5 I get the following error messages:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;X The document was not printed due to an error&lt;/li&gt;
&lt;li&gt;X Exception encountered inside [PlotContext.OutputElement]&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Occurs for every plan and section cut from a model.&lt;/p&gt;
&lt;p&gt;Only started happening last night.&lt;/p&gt;
&lt;p&gt;I&amp;#39;ve detached all the model files from the Master model file, compressed the file, reattached and the same thing happens.&lt;/p&gt;
&lt;p&gt;Any ideas?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Drawing referenced into a Sheet is masking another Drawing</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/146284/drawing-referenced-into-a-sheet-is-masking-another-drawing</link><pubDate>Mon, 29 Jan 2018 16:27:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:880ec800-f278-482f-872c-2a20f3a4d760</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;I am using ABD SS6 V8i, we have design models, composition models, drawings and sheets.&amp;nbsp; Drawings were created from saved view in composition file.&amp;nbsp; We have a problem where&amp;nbsp;a drawing referenced on a sheet is masking another drawing ( overall plan drawing and&amp;nbsp;Stair drawing).&amp;nbsp; I have tried update sequence but it doesn&amp;#39;t do anything.&amp;nbsp; If I turn off reference display and only show individually I can see that it&amp;#39;s is there, that&amp;#39;s how I know its been masked by the other Drawing reference.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Any ideas on how to solve this?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>File is currently in use by:</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/145746/file-is-currently-in-use-by</link><pubDate>Tue, 16 Jan 2018 21:54:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c8c30caf-346d-4785-9d7b-b25388b1ec02</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;We are on the network with multiple users and have been locked out of a specific file for a day now.&amp;nbsp; The Read Only message does not say which computer has it opened (normally it does).&lt;/p&gt;
&lt;p&gt;We disabled out preview panes in windows explorer, tried shutting down computers but still the file is locked!We have tried opening the file through windows explorer and Bentley explorer window.&lt;/p&gt;
&lt;p&gt;We have no idea how to unlock this file and we need to make changes (its a design model file).&amp;nbsp; We are using Windows 7 - AECOsim V8i SS6 version 08.11.09.866&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1516139364202v1.jpeg" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Please help.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Composition Saved View versus Drawing View looks different</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/152996/composition-saved-view-versus-drawing-view-looks-different</link><pubDate>Tue, 24 Apr 2018 16:19:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59a1f8fc-b4cb-44eb-9b14-5b13b871a2cb</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;Hi All,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I am using&amp;nbsp;:&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1524586522170v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I have a drawing file which was created from a saved view in a composition file but can&amp;#39;t figure out way the look different.&amp;nbsp; There is a wall in between the stairs so I shouldn&amp;#39;t see the stairs behind the wall (as shown in composition saved view):&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1524586646079v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;In my drawing file (created from saved view above), the wall appears to be transparent??&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1524586756638v4.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Please help.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>REPLACE NEW SPACE LABEL TAGS WITHOUT AFFECTING POSITION OF OLD SPACE LABEL TAG WHEN REFRESHING?</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/148507/replace-new-space-label-tags-without-affecting-position-of-old-space-label-tag-when-refreshing</link><pubDate>Tue, 20 Mar 2018 18:19:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b4f202a8-d6ca-4a2b-b6a0-918b75ab0cbe</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;Using Aecosim V8i,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img height="50" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1521569842182v1.png" width="431" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;We have been using a particular space label for room labels annotations, we have made a slight change to that same space label (separated room name, number and area on different levels).&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;How can we push this through out the project without affecting the position of previously paced space labels.&amp;nbsp; when we refresh annotations, the space labels tend to move to its default position (center of the room).&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Room Label Units - Sq.m to Sq. mm?</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/145811/room-label-units---sq-m-to-sq-mm</link><pubDate>Wed, 17 Jan 2018 21:14:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8e6315f6-f535-4dd6-bd05-b69c4fbb178c</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;We have a project with multiple users, all of a sudden our room labels areas are in sq.mm instead of sq.meters.&lt;/p&gt;
&lt;table class="messageTable" id="messageTable"&gt;
&lt;tbody id="messageTableBody"&gt;
&lt;tr class="msg"&gt;
&lt;td class="msgText normalMsgText" id="msg_id_4" colspan="1"&gt;
&lt;div&gt;
&lt;div style="padding-bottom:1.3em;"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1516223511775v1.png" alt=" " /&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/td&gt;
&lt;td class="timeStamp" title="January 17, 2018"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;Preferences settings are as follows:&lt;/p&gt;
&lt;p&gt;&lt;img height="323" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1516223586812v4.png" width="347" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Any ideas on how to fix the units to read square meters?&lt;/p&gt;
&lt;p&gt;ABD V8i SS6&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Floor levels not where they should be</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/146629/floor-levels-not-where-they-should-be</link><pubDate>Mon, 05 Feb 2018 15:14:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6f461d09-3302-4ea6-a4db-23aeb748d0bb</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;I have floor levels set at specific elevations, for some reason certain elevations are not at the level it is supposed to be once the elevation datums are generated!?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1517843396781v3.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1517843637609v5.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;T/o North Exhaust Structure Roof 178850 is where it should be, but the Main Entrance FFL 171575 is shown about 24 metres below.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Why is this happening?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can&amp;#39;t release write lock on specific files</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/146907/can-t-release-write-lock-on-specific-files</link><pubDate>Mon, 12 Feb 2018 15:48:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e8c8d5e7-1e5e-4030-a7b1-c8d1f602c84b</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;Been having this issue for months, a few specific files (design models)&amp;nbsp;constantly keep getting locked out even when nobody is working in those files directly.&amp;nbsp; When I click on the write-lock check mark and hit OK to release it....nothing happens and the check mark remains.&amp;nbsp; We constantly have to wait until the write lock gets magically released in which we can actually make modifications to that design model.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1518450397990v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;This has been a big issue and hoping to finally resolve it.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Using AECOsim SS6 V8i&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1518450433685v2.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>how to replace Call Out standard square shape with rounded corners?</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/146299/how-to-replace-call-out-standard-square-shape-with-rounded-corners</link><pubDate>Mon, 29 Jan 2018 19:59:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7be85c6f-4e86-4ecd-aa50-29c736f05574</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;We have placed several call outs through the project to develop enlarged plans etc.&amp;nbsp; The client standards request that the call out symbol must have rounded corners.&amp;nbsp; We have use the standard square shape when we initially placed them.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Please tell me there is a way to redefine the shape?&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1517255901730v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Current Shape of Callout to be replaced with:&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1517255943882v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to modify detail callout shape after it is placed</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/146035/how-to-modify-detail-callout-shape-after-it-is-placed</link><pubDate>Tue, 23 Jan 2018 16:59:55 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6a99a2d3-1d57-41b4-88ad-d58ac33fd8dd</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;Our project is well underway, we have placed several detail callouts for enlarged partial plans.&amp;nbsp;The client requests for the detail callout symbol to have rounded corners.&amp;nbsp; How can we modify each detail callout (all ready placed) to have rounded corners??&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Partial Plan workflow - All detail callouts have been placed created&amp;nbsp;on the SHEETS, which then creates a SAVED VIEW&amp;nbsp; to our composition model, which we then create a DRAWING file from that SAVED VIEW.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img height="238" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1516726693406v1.png" width="498" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Using AECOsim V8i SS6&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>AECosim SS6  V8i - floor manager units have changed!</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/146494/aecosim-ss6-v8i---floor-manager-units-have-changed</link><pubDate>Thu, 01 Feb 2018 16:52:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:57c017c8-6217-4d27-9882-d8de245e455a</guid><dc:creator>serraric</dc:creator><description>&lt;p&gt;We have always had out floor manager elevations in this format 147324 and now it comes in at 147.324, I tried changing the design file units and the preferences and can&amp;#39;t seem to revert back.&amp;nbsp;&lt;/p&gt;