<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Ryan Ankabrandt's Communities Activities</title><link>https://communities.bentley.com/members/23545572_2d00_0969_2d00_4662_2d00_afe5_2d00_6e13804da29f</link><description>Recent activity for people in Ryan Ankabrandt's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>RAM Concept - Mat Slab on grade - Reinforcement</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/117448/ram-concept---mat-slab-on-grade---reinforcement</link><pubDate>Fri, 25 Mar 2016 18:08:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9015e229-81c6-42a0-a89d-40c67f0dc72c</guid><dc:creator>Ryan Ankabrandt</dc:creator><description>&lt;p&gt;I&amp;#39;m working on a mat slab on grade to support a silo at a concrete batch plant and wanted to model the slab in RAM Concept.&lt;/p&gt;
&lt;p&gt;1. Our model for a slab on grade has flagged ACI318 section 7.12.&amp;nbsp; Per ACI318 section R7.12.1, this section is not for slabs-on-grade.&amp;nbsp; Why does RAM Concept check temperature and shrinkage reinforcement for a mat slab on grade, and is there a way to turn off this check?&lt;/p&gt;
&lt;p&gt;2. Is there a way to change RAM&amp;#39;s &lt;span style="text-decoration:underline;"&gt;program assigned&lt;/span&gt; distributed reinforcement default output from number of bars to a bar spacing (without changing to user defined bar spacing)?&lt;/p&gt;
&lt;p&gt;3. Is there a way to view/output the formulas and calculations (for a report),&amp;nbsp;similar to RAM Connection&amp;#39;s reports?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>