<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Rob Greening's Activities</title><link>https://communities.bentley.com/members/28d50a3e_2d00_e62b_2d00_4b9e_2d00_bc54_2d00_a242d3440a64</link><description>Rob Greening's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>STAAD Foundation Advanced - Pedestal Reinforcement Ratio</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/203402/staad-foundation-advanced---pedestal-reinforcement-ratio</link><pubDate>Fri, 18 Sep 2020 15:47:23 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:27c96224-b3fa-421d-a8c0-814f64f1c146</guid><dc:creator>Rob Greening</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;I am designing an isolated spread footing using ACI 318-05 with SFA Build 9.2.0.34.&amp;nbsp; When designing the pedestal SFA provides an area steel of around 1% the gross area of the pedestal.&amp;nbsp; However, ACI 318-05 Section 10.8.4 and&amp;nbsp;15.8.2.1 state a steel area of 0.5% the gross area may be used if the cross section is larger than required for the given factored loads.&lt;/p&gt;
&lt;p&gt;I see from a previous post (&lt;a href="/products/ram-staad/f/ram-staad-forum/199690/sfa-isolated-foundation-doesn-t-design/596308#596308"&gt;https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/199690/sfa-isolated-foundation-doesn-t-design/596308#596308)&lt;/a&gt;&amp;nbsp;that the option to reduce this area was removed because ACI 318 removed those clauses from later versions.&lt;/p&gt;
&lt;p&gt;However since I am designing to an older version of the code, is there a way for SFA to consider the reduced gross area of the column/reduced area of steel required per the previously mentioned sections of ACI 318-05?&amp;nbsp; Alternatively, is there a way for SFA to treat the pedestal as a rigid element and not provide a design?&lt;/p&gt;
&lt;p&gt;Thanks for your help&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Fri, 18 Sep 2020 02:52:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3e0fc795-471f-4cc5-8dac-529f1cc69599</guid><dc:creator /><description>Ask a question in a forum.</description></item></channel></rss>