• RE: how to set pump definition right? how to have similar tank level as scada?

    Calibrating pumps and tanks in an EPS model depends on the source of error. You need to proceed logically. Usually, the easiest thing to check is the pump curve. Measure the flow and pump head over a range of conditions (try throttling the discharge…
  • Problem with wtg.sqlite

    Hello! I need help! I have a problem with wtg.sqlite file and i can open my project .I tryed to open bak file and renamed it but nothing happens... So if anyone can help me with the files and next send me back the recover project i will be thankful! I…
  • PROBLEM WITH SCADAconnect SIMULATOR

    Hi everyone and thank you very much for your time!!! I have a question about the scadaconnect simulator . (we run watergems connect edition update 2) I have a water supply network that has 3 reservoirs, and 3 boreholes (active). While I pass the files…