<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>JT's Communities Activities</title><link>https://communities.bentley.com/members/441fddbb_2d00_349c_2d00_4dbe_2d00_9cbc_2d00_92293883654a</link><description>Recent activity for people in JT's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>RAM Concept Shear Reinforcement Section Design</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/242167/ram-concept-shear-reinforcement-section-design</link><pubDate>Mon, 27 Feb 2023 03:23:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f1b45e24-7b51-4bce-a325-7aa56209577c</guid><dc:creator>JT</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I&amp;#39;m trying to get a deeper understanding of why RAM Concept is showing my shear requirement as being larger than the same beam I have modelled in RAPT to verify. RAPT does not require any additional shear reinforcement.&amp;nbsp;I have checked the shear core and that seems to be OK.&lt;/p&gt;
&lt;p&gt;As an example, I have been looking at design section 24C-2, section 2 in the model I have uploaded via secure link and have the following questions:&lt;/p&gt;
&lt;p&gt;1. Why is the design section minimum demand (-1427kN) significantly larger than the design strip maximum shear in this span (-533kN)? What does the design section demand mean?&lt;/p&gt;
&lt;p&gt;2. From the cross section audit Envelope 7 of the Final Design Check for Strength design, phi Vuc = 0.75 x 2043kN = 1530kN &amp;gt; 1427kN. Why is shear reinforcement added when capacity &amp;gt; demand and what determines that they need to be closed ligs?&lt;/p&gt;
&lt;p&gt;3. Why is there bottom reinforcement required at the column at this location rather than at mid-span if anywhere? Similar question applies to the beam in the north-eastern corner of the building.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Regards&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Mon, 27 Feb 2023 00:45:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:daab6ab8-0885-44cb-86c9-b4f84ac00286</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>RAM Concept - Load History Deflections Not Converging</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/198086/ram-concept---load-history-deflections-not-converging</link><pubDate>Mon, 01 Jun 2020 06:56:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:858764b1-a376-42e8-aa11-a9a7186f6a5a</guid><dc:creator>Stacey Klein</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I have two RAM Concept suspended slab models which will not converge when running the load history deflections and I am at a loss as too why. Below is the warning provided in the Load History Calc Log:&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;em&gt;WARNING: An error has been found while calculating load history deflections. The load history deflection solution did not converge. The expected deflection error is 1.803 mm&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;&lt;em&gt;&amp;nbsp;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Information which may be helpful:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Suspended slab minimum thickness 600mm&lt;/li&gt;
&lt;li&gt;Models of Basements 4 and 5 - Walls all around with internal columns&lt;ul&gt;
&lt;li&gt;Models of Ground to Basement 3 are very similar and do converge&lt;/li&gt;
&lt;li&gt;I am unsure if this is purely coincidental but the columns change from rectangular in G-B3, to circular in B4 and B5.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;li&gt;Calc Option Parameters are in screen shots&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/Calc-Options.jpg" /&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/Calc-Options-2.jpg" /&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;Changes made to try and resolve issue&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Iterations to use increased to 20 (both under zero-tension and load history)&lt;/li&gt;
&lt;li&gt;Checked with user only reo and with program reo&lt;/li&gt;
&lt;li&gt;Fixed meshing warning of some wall centrelines not joining&lt;ul&gt;
&lt;li&gt;Models of Ground to Basement 3 have the same warnings and do converge&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;Are you able to provide any guidance on how I may be able to get these models to converge in order to get accurate load history deflection results?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>