<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Jacob Oviedo's Activities</title><link>https://communities.bentley.com/members/589185bf_2d00_8dd4_2d00_4c44_2d00_8327_2d00_4177802fa314</link><description>Jacob Oviedo's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Drainage and Utilities Connecting Links not showing up in Utility Properties</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/236995/drainage-and-utilities-connecting-links-not-showing-up-in-utility-properties</link><pubDate>Fri, 14 Oct 2022 16:25:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f0e26a4a-7c94-480a-89b7-9a87cd14894f</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;I have a couple storm sewer utility runs drawn.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Where one of my nodes have 3 different conduits connect too, in the properties how ever it only shows one&amp;nbsp;&lt;/p&gt;
&lt;p&gt;connecting link. I&amp;#39;m attempting to resolve this so i can annotate all of the connecting conduit flowlines.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Any body come across this or know how to correct?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/pastedimage1665764757207v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5922/B_2D00_3d_2D00_Proposed_5F00_UTL.dgn"&gt;communities.bentley.com/.../B_2D00_3d_2D00_Proposed_5F00_UTL.dgn&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>SU Node/Conduit Profile Cell</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/234191/su-node-conduit-profile-cell</link><pubDate>Wed, 17 Aug 2022 18:58:30 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4c5732b9-671c-4373-b840-16fb3edfb656</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;A few questions regarding SU Profiling if anybody has any experience...&amp;nbsp;&lt;/p&gt;
&lt;p&gt;1. I attempted to create a profile run and set my Node Draw Type to Cell. When I open up the profile I only see a cell with a couple lines representing the node.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;does anybody know where I would go to update or recreate Node profile cells?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;2. I&amp;#39;m also trying to see wall thickness of conduits on my Storm Profile Run, does anybody know how I get get that done?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;3.Is it possible for the program to output ellipses of crossing conduits in my Utility Run?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I&amp;#39;m Attempting to achieve the questions above for Plan and profile production where I would Project the Util Runs to a baseline fyi.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Any help regarding these topics would be greatly appreciated.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Thanks.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/pastedimage1660762657130v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Adjust Placement of Profile Named Boundary Model</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/234113/adjust-placement-of-profile-named-boundary-model</link><pubDate>Tue, 16 Aug 2022 14:11:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cd788ff5-3747-45fd-b3c6-a628f7d5a7b0</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;Curious if it&amp;#39;s possible to change location of where my profile named boundary is placed?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/pastedimage1660658506580v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;The profile I created is exaggerated by 10, you can see the starting elevation is 90 &amp;amp; matches the Y value.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I would prefer if my Y value equaled 900 at the 90 elevation; and to continue my example&amp;nbsp; at elevation 100 I would prefer the Y value to equal 1000.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;We already use this&amp;nbsp;logic&amp;nbsp;with Inroads program &amp;amp; allows the cad guys to check against any elevations fairly quickly. Does anybody know how I can accomplish this?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Best Practice For Profile Production</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/232010/best-practice-for-profile-production</link><pubDate>Thu, 30 Jun 2022 19:44:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f11779fb-ac11-4839-af87-619c72ae1631</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;Attempting to put together a profile using multiple references.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I have sub surface utilities in a file where I can annotate&amp;nbsp;subsurface utilities in profile view.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;In another file where I am attempting to create a profile named boundary;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I&amp;#39;m not see the subsurface utilities being annotated in my named boundary file like how I&amp;#39;d want.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Anybody know the cause of this? and work around?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/pastedimage1656618171299v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Image shows how my profile run is being annotated in my named boundary file;&lt;/p&gt;
&lt;p&gt;where in my SU file placeholders for annotation is actually being filled in.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/pastedimage1656618120785v2.png"&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Updating DGNLIBs</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/231951/updating-dgnlibs</link><pubDate>Wed, 29 Jun 2022 19:29:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:32ab76e2-1d52-4700-a886-1662ea413357</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;I&amp;#39;ve been working on preparing company standard feature definitions,&amp;nbsp;&lt;span&gt;feature symbologies, annotation groups, and text favorites.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;I&amp;#39;ve been preparing these features in working files, and now I want to import them into the appropriate&amp;nbsp;dgn libs. Anybody know how I can update a dgnlib with specific features&amp;nbsp;from another dgn?&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Thanks&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Box Culvert Headwall to Headwall</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/226184/box-culvert-headwall-to-headwall</link><pubDate>Tue, 22 Feb 2022 14:57:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5b4c4959-f1dc-4d67-9519-fe39f66af0cc</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;I&amp;#39;m attempting to place a couple box culverts for a water crossing.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;The program doesn&amp;#39;t seem to like it when I try to place conduit between two headwall nodes.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Does anybody know a work around for this?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Tue, 08 Feb 2022 02:06:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8a002c43-8eb5-4b6f-a8e4-73e574fcf2a5</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>Water Segment Size</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/225554/water-segment-size</link><pubDate>Tue, 08 Feb 2022 22:41:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:df18ca70-3123-492c-9cea-bf9fa3a52a63</guid><dc:creator>Jacob Oviedo</dc:creator><description>&lt;p&gt;How do I add an additional sizes to a pvc water segment?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Default library only includes 4&amp;quot; and 6&amp;quot;, I&amp;#39;ve figured out where to go in the case&amp;nbsp;&lt;/p&gt;
&lt;p&gt;of Storm Conduits, but it doesn&amp;#39;t seem to be the case for other utilities?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Anybody have suggests?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>