<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Roald Tvedt's Communities Activities</title><link>https://communities.bentley.com/members/599b2442_2d00_4809_2d00_4dcc_2d00_92ad_2d00_cb6e7b9f1c5a</link><description>Recent activity for people in Roald Tvedt's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>[CONNECT] Disable Workset Verification</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/181749/connect-disable-workset-verification</link><pubDate>Thu, 27 Jun 2019 12:05:22 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:405126fa-f8d3-4d62-817f-ef1623568afb</guid><dc:creator>Daniel Grohmann</dc:creator><description>&lt;p&gt;Hello everybody,&lt;/p&gt;
&lt;p&gt;in our organization we work in a workspace/workset configuration within&amp;nbsp;our cad operators have to load/open different dgn files not assigned to any worksets.&lt;/p&gt;
&lt;p&gt;Is there an environment variable/method/function im CONNECT to suppress the workset verification? Because the dgn files were manipulated from different worksets. An assignment to&amp;nbsp;only one workset isn&amp;#39;t practical.&lt;/p&gt;
&lt;p&gt;I moved the dgn files to directories the variables MS_WORKSETMISMATCH_ALERT_EXCLUDE_* are pointing to but at all times the workset alert message appers.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;best regards&lt;/p&gt;
&lt;p&gt;Daniel&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>MicroStation Connect Edition issues</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/227908/microstation-connect-edition-issues</link><pubDate>Sat, 02 Apr 2022 09:46:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:fcc377ec-d9cf-4ec7-8a72-78c397983814</guid><dc:creator>Roald Tvedt</dc:creator><description>&lt;p&gt;I try to %include a cfg into my configuration without success. Get the same error message wherever I place the cfg File.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343321/Incude.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Is there another way to make cfg files to be read in the WorSets config Level except in the Root Folder -&amp;gt;&amp;nbsp;$(_USTN_WORKSETSROOT) ?&lt;/p&gt;
&lt;p&gt;This is MicroStation version 10.16.02.34&lt;/p&gt;
&lt;p&gt;---------------------------------------------------&lt;/p&gt;
&lt;p&gt;XMPL:&lt;/p&gt;
&lt;p&gt;Why can&amp;#39;t I %include file test.cfg in the folder .&lt;/p&gt;
&lt;p&gt;...........\Configuration\WorkSpaces\Equinor\WorkSets\Bacalhau\Standards\Data\ ?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question II</title><link>https://communities.bentley.com/achievements/cd3cd235-25c1-476e-bb88-33a5705ca45a</link><pubDate>Sat, 02 Apr 2022 09:18:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2d0c1d9f-2f88-48c6-8c0d-36f82b2c674a</guid><dc:creator /><description>Ask 10 questions in a forum.</description></item><item><title>Is there an env. variable available for starting MicroStation CE U16 with a startup txt file (containing keyins). I&amp;#39;m aware that there is a user preference in Update 16, but an env. variable is much more flexible.</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/226609/is-there-an-env-variable-available-for-starting-microstation-ce-u16-with-a-startup-txt-file-containing-keyins-i-m-aware-that-there-is-a-user-preference-in-update-16-but-an-env-variable-is-much-more-flexible</link><pubDate>Fri, 04 Mar 2022 07:56:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:97da0b7e-2bbb-4098-90fe-4a045a82fa65</guid><dc:creator>Roald Tvedt</dc:creator><description>&lt;p&gt;EXAMPLE:&lt;/p&gt;
&lt;p&gt;start &amp;quot;Aibel AS. Iso2Ustn for MicroStation Connect Edition&amp;quot; /D %Appl_Root% /HIGH %app% -&lt;span style="font-family:impact, chicago;"&gt;S%StartupFile%&lt;/span&gt; -WK%CurrentWorkSpace% -WW%currentWorkSet% %StartupCadFile%&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>MicroStation Font 106. Any recommended TT Fonts replacing this?</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/212091/microstation-font-106-any-recommended-tt-fonts-replacing-this</link><pubDate>Tue, 06 Apr 2021 07:15:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:74075aab-d74c-4494-a0ea-9c16f5b9c876</guid><dc:creator>Roald Tvedt</dc:creator><description>&lt;p&gt;I need a TT Font similar to replace the monospace MicroStation&amp;nbsp; font INTL_ISO_EQUAL.&lt;/p&gt;
&lt;p&gt;MicroStation CE U15 and MicroStation V8i SS10.&lt;/p&gt;
&lt;p&gt;Any suggestion?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>MicroStation Configuration Variables containing slash /</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/200666/microstation-configuration-variables-containing-slash</link><pubDate>Tue, 21 Jul 2020 10:42:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:62744f86-746c-429f-87c4-bc79e804a49e</guid><dc:creator>Roald Tvedt</dc:creator><description>&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;.....in a *.cfg file:&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;PD_ISYPLOT_PREFIX = B&lt;span style="color:#ff0000;"&gt;/&lt;/span&gt;W&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;In MicroStation, this Reuslts in Value B&lt;span style="color:#ff0000;"&gt;\&lt;/span&gt;W.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;Hoe can I get Value to stay&amp;nbsp;&lt;span style="background-color:#ffffff;color:#000000;float:none;font-family:Verdana,Arial,Helvetica,sans-serif;font-size:12px;font-style:normal;font-weight:400;letter-spacing:normal;text-align:left;text-decoration:none;text-indent:0px;text-transform:none;white-space:normal;"&gt; B&lt;/span&gt;&lt;span style="color:#ff0000;"&gt;/&lt;/span&gt;&lt;span style="background-color:#ffffff;color:#000000;float:none;font-family:Verdana,Arial,Helvetica,sans-serif;font-size:12px;font-style:normal;font-weight:400;letter-spacing:normal;text-align:left;text-decoration:none;text-indent:0px;text-transform:none;white-space:normal;"&gt;W&lt;/span&gt; ???&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Let me Help You</title><link>https://communities.bentley.com/achievements/687f4b6d-e18a-4e55-836c-49926ca2c9d9</link><pubDate>Fri, 18 Oct 2019 15:07:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bed1a580-d99b-4ced-a48d-336c8ef3207e</guid><dc:creator /><description>Answer a question that is verified as helpful or correct.</description></item><item><title>ms10130101en_updt13.exe error</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/185727/ms10130101en_updt13-exe-error</link><pubDate>Tue, 17 Sep 2019 18:19:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:de61cae5-084b-4205-92fd-5adbb2072f3a</guid><dc:creator>Bob Rayner</dc:creator><description>&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343321/pastedimage1568744356746v1.png" /&gt;&lt;/p&gt;
&lt;p&gt;My $7000 software with the $1000 a year maintenance has been a real poop sandwich for the last year or so.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CE WorkSet warnings.</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/185065/ce-workset-warnings</link><pubDate>Wed, 04 Sep 2019 17:28:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:40e98742-49ce-47e7-abce-ca9fcef8df16</guid><dc:creator>Roald Tvedt</dc:creator><description>&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;Our Company users should be able to open design files i any WorkSpace/ WorkSet without warnings.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;Setting &amp;nbsp;MS_WORKSETMISMATCH_ALERT_EXCLUDE_VARS_ALLLEVELS=&lt;strong&gt; $(_DGNDIR)&lt;/strong&gt; does not work.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;Setting&amp;nbsp;MS_WORKSETMISMATCH_ALERT_EXCLUDE_VARS_WORKSPACELEVEL=&lt;strong&gt; $(_DGNDIR)&lt;/strong&gt; does not work.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;Why not? &lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffffff;"&gt;How to resolve?&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Wed, 04 Sep 2019 01:09:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98f82e84-b69e-491b-86ee-fc6fc332e9ba</guid><dc:creator /><description>Ask a question in a forum.</description></item></channel></rss>