<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Josh Healey's Communities Activities</title><link>https://communities.bentley.com/members/6779229a_2d00_11f3_2d00_4b1d_2d00_b610_2d00_537f96253cda</link><description>Recent activity for people in Josh Healey's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Curtain Walling</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/201643/curtain-walling</link><pubDate>Tue, 11 Aug 2020 14:19:19 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d59b0dd-a0b1-4998-bc59-544ac24ac0d2</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Hi Guys,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Just a quick question regarding curtain walling. I have drawn up the model and entered all windows, doors etc into the model, however parts of the building are curtain walling only? Is the best method of entering the curtain walling by generating a new wall in the fabric properties and entering all data such as dimensions, thickness, material type and U-value etc or by leaving the wall as a standard brick wall and inputting the glass so it covers the full wall with all the relevant properties?&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;
&lt;p&gt;Josh&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>BRUKL document data not changing</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/191739/brukl-document-data-not-changing</link><pubDate>Wed, 29 Jan 2020 12:22:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6038f922-59e8-4eea-8538-caabb6387a58</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Changing the data in my Hevacomp model is fine and get a different set of results in the results tab page. The compliance document however has not modified inline with the data changes and remains at the previous revision.&lt;/p&gt;
&lt;p&gt;No parts of the model have been put as shell and core &amp;amp; have tried exiting the model once the changes have been made and re-entered the model to run and nothing again changes?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Is there anything I can do so the BRUKL alters to the data inputted? I haven&amp;#39;t had this issue before.&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;
&lt;p&gt;Josh&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Air Source Heat Pump System</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/157335/air-source-heat-pump-system</link><pubDate>Mon, 02 Jul 2018 08:51:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:449af2c5-7f7e-4ec2-9726-1bccb6fee2cc</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;Wanted to clarify my HVAC system type set up. The project involves an Air source heat pump feeding a heat exchanger within the plantroom which then feeds a pre heat storage vessel.&lt;/p&gt;
&lt;p&gt;The storage vessel flows runs into the Gas fired water heaters&amp;nbsp; into a hot water storage cylinder which feeds the building&amp;#39;s hot water as the heating system is electric heating.&lt;/p&gt;
&lt;p&gt;Within the SBEM how would the Plantroom HVAC system type be set up? Any advice on this would be great&lt;/p&gt;
&lt;p&gt;Below is how I have the Plantroom currently set up within SBEM and also an image of the drawing.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1530521429691v3.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1530521386377v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1530521345934v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;
&lt;p&gt;Josh Healey&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>SBEM Notional Heating</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/146838/sbem-notional-heating</link><pubDate>Fri, 09 Feb 2018 11:05:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:11c921e2-767b-426d-8e9e-b86d0e65a313</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Currently completing an SBEM with retail units that have a toilet, kitchen and eating area. Kitchen and Toilet area has no heating or cooling in it and the restaurant eating area has heat pumps so there should be a notional heating value within the compliance report?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Getting the Part L to Pass, however looking at the report there is no notional heating value but there is an actual heating value present. Cooling values also seem fine.&lt;/p&gt;
&lt;p&gt;Tried it without Heat recovery and any ventilation and that seems to bring the heating value to a reasonable level, thought it could be the angle from north as to why there is no notional heat value. Is there an issue with my model?&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;
&lt;p&gt;Josh&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>EPC error</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/139931/epc-error</link><pubDate>Fri, 18 Aug 2017 08:42:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:53ce2ff1-1018-4673-90be-fb53b20fea9d</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Currently producing an energy report and an EPC is required. When selecting the EPC tab an error comes up as shown by the image below.&lt;/p&gt;
&lt;p&gt;The project has been set up by another person so unsure if there is an error in setup, but have noticed within the documents that there is a PartL2006.dat file in the folder so I have tried to delete this several times in the hope this will correct the error but with no success and there is no other option to view the EPC as said in the error box.&lt;/p&gt;
&lt;p&gt;Any help would be great&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/275871/pastedimage1503045629515v1.png"&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1503045629515v1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Heat Interface Units</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/139156/heat-interface-units</link><pubDate>Mon, 31 Jul 2017 15:43:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ad76deef-e571-451e-9f86-691e236c5286</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;Just a query in how to input heat interface units into hevacomp within a Part L SBEM assessment. Currently I have inputted a plant room as its own zone with the system chosen as LTHW Boiler and Nat Gas with the DHWS also same as the heating source. The rest of the zones have also been selected as the same as the Plantroom sources heating and HWS.&lt;/p&gt;
&lt;p&gt;Is this the correct method or is making the plantroom zone a district heating system a better method when inputting Heat interface units? Any info on this would be great&lt;/p&gt;
&lt;p&gt;Josh&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Mon, 31 Jul 2017 02:30:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:fea3bff5-5d97-412a-aaa5-6fe16c80b75b</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>Hevacomp Netsys</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/129223/hevacomp-netsys</link><pubDate>Mon, 05 Dec 2016 13:13:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9e65f5fe-852f-41a9-a1f1-9acc3a8142f1</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Recently created a Netsys project for duct calculations. Have come to re-open the project but when it comes to opening it up on the project explorer screen, the green tick that comes up that you click to re-enter the project comes up for half a second and vanishes so I am currently unable to re-open the file. The design database at the side has all the info such as no of rooms, date last used etc. &amp;amp; nothing has been touched in terms of the folders within our system. Is there a way to enter the project again?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;
&lt;p&gt;Josh&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Floor Change Connector</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/128966/floor-change-connector</link><pubDate>Mon, 28 Nov 2016 16:28:30 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:38cb4d1b-312c-4ba5-b993-179d52e309c0</guid><dc:creator>Josh Healey</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I am currently in the process of building a CWS pipe sizing model. I completed the top floor and copied the rest of the floors (6 Storey Build). After copying each floor as they are exactly the same I have added a floor change connector in order to connect the pipes within the riser as it would in an install. The Schematic shows the pipes connected in the isometric model. However, when I add a system marker in order to size the pipes on each floor it only sizes them on the current floor I am on rather than the system as a whole? Would it be preferable for me to draw each floor system in rather than copy or is there a way around this?..&lt;/p&gt;
&lt;p&gt;Thanks,&lt;/p&gt;
&lt;p&gt;Josh&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>