<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>vivekshine's Activities</title><link>https://communities.bentley.com/members/6e9522fd_2d00_0eb9_2d00_46bc_2d00_b4ac_2d00_a928cb94900b</link><description>vivekshine's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Maximum Utility ratio for each section in STAAD</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/243307/maximum-utility-ratio-for-each-section-in-staad</link><pubDate>Fri, 24 Mar 2023 05:50:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:195df819-72ce-43c4-a51a-feb7bed9ec91</guid><dc:creator>Vivekanandan K</dc:creator><description>&lt;p&gt;Is there any option to see Maximum Utility ratio for each section in STAAD. In v8i version we can take the Maximum Utility ratio table using SQL query. but in CE version it is not available. Is there any option to see this format table.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Existing RCC wall analysis in STAAD</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/136087/existing-rcc-wall-analysis-in-staad</link><pubDate>Tue, 09 May 2017 10:03:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:91abf298-fbea-4d7e-8552-83f19ed11f66</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;I have to analyse an existing RCC wall. I have the wall dimension and rebar details.&lt;/p&gt;
&lt;p&gt;How to model RCC in STAAD. I can able to model only concrete as shear wall(surface). But could not add any steel reinforcement in to the wall. Can anyone tell me the procedure to analyse such RCC wall to find the load bearing capacity of the wall. &amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Mon, 27 Sep 2021 14:15:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:579abe44-df38-41c2-af5e-d59239f2d148</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>UNT /UNB is based on flange or bracing</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/220025/unt-unb-is-based-on-flange-or-bracing</link><pubDate>Mon, 27 Sep 2021 14:15:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:03c58ded-9bf8-4f23-825b-927c238b1c47</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;In the attached&amp;nbsp;model UNB/UNT values for intermediate secondary members(Z direction) as 1m and &amp;nbsp;Primary members (X-Direction)&amp;nbsp; as 5 m(Physical beam length).&lt;/p&gt;
&lt;p&gt;Taking UNT/UNB for &lt;span&gt;Primary&amp;nbsp;&lt;/span&gt;members (&lt;span&gt;UC305X305X97&lt;/span&gt;) as 5m is correct or do we need to consider 1m as this beams are tied at 1m interval?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;IS UNT UMN Ly is same in most Cases?&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1632751971920v1.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;STAAD SPACE&lt;br /&gt;START JOB INFORMATION&lt;br /&gt;ENGINEER DATE 02-Sep-21&lt;br /&gt;END JOB INFORMATION&lt;br /&gt;INPUT WIDTH 79&lt;br /&gt;UNIT METER KN&lt;br /&gt;JOINT COORDINATES&lt;br /&gt;1 0 0 0; 2 1 0 0; 3 2 0 0; 4 3 0 0; 5 4 0 0; 6 5 0 0; 7 0 0 1; 8 1 0 1;&lt;br /&gt;9 2 0 1; 10 3 0 1; 11 4 0 1; 12 5 0 1; 13 0 0 2; 14 1 0 2; 15 2 0 2; 16 3 0 2;&lt;br /&gt;17 4 0 2; 18 5 0 2; 19 0 0 3; 20 1 0 3; 21 2 0 3; 22 3 0 3; 23 4 0 3; 24 5 0 3;&lt;br /&gt;25 0 0 4; 26 1 0 4; 27 2 0 4; 28 3 0 4; 29 4 0 4; 30 5 0 4;&lt;br /&gt;MEMBER INCIDENCES&lt;br /&gt;1 1 2; 2 2 3; 3 3 4; 4 4 5; 5 5 6; 6 1 7; 7 2 8; 8 3 9; 9 4 10; 10 5 11;&lt;br /&gt;11 6 12; 12 7 8; 13 8 9; 14 9 10; 15 10 11; 16 11 12; 17 7 13; 18 8 14;&lt;br /&gt;19 9 15; 20 10 16; 21 11 17; 22 12 18; 23 13 14; 24 14 15; 25 15 16; 26 16 17;&lt;br /&gt;27 17 18; 28 13 19; 29 14 20; 30 15 21; 31 16 22; 32 17 23; 33 18 24; 34 19 20;&lt;br /&gt;35 20 21; 36 21 22; 37 22 23; 38 23 24; 39 19 25; 40 20 26; 41 21 27; 42 22 28;&lt;br /&gt;43 23 29; 44 24 30; 45 25 26; 46 26 27; 47 27 28; 48 28 29; 49 29 30;&lt;br /&gt;DEFINE MATERIAL START&lt;br /&gt;ISOTROPIC STEEL&lt;br /&gt;E 2.05e+008&lt;br /&gt;POISSON 0.3&lt;br /&gt;DENSITY 76.8195&lt;br /&gt;ALPHA 1.2e-005&lt;br /&gt;DAMP 0.03&lt;br /&gt;TYPE STEEL&lt;br /&gt;STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2&lt;br /&gt;END DEFINE MATERIAL&lt;br /&gt;MEMBER PROPERTY BRITISH&lt;br /&gt;1 TO 6 11 TO 17 22 TO 28 33 TO 39 44 TO 49 TABLE ST UC305X305X97&lt;br /&gt;7 TO 10 18 TO 21 29 TO 32 40 TO 43 TABLE ST UB203X133X30&lt;br /&gt;CONSTANTS&lt;br /&gt;MATERIAL STEEL ALL&lt;br /&gt;SUPPORTS&lt;br /&gt;1 6 13 18 25 30 PINNED&lt;br /&gt;LOAD 1 LOADTYPE None TITLE LOAD CASE 1&lt;br /&gt;SELFWEIGHT Y -1 &lt;br /&gt;MEMBER LOAD&lt;br /&gt;1 TO 49 UNI GY -30&lt;br /&gt;PERFORM ANALYSIS PRINT ALL&lt;br /&gt;PARAMETER 1&lt;br /&gt;CODE AISC UNIFIED 2010&lt;br /&gt;UNB 5 MEMB 1 TO 5 12 TO 16 23 TO 27 34 TO 38 45 TO 49&lt;br /&gt;UNT 5 MEMB 1 TO 5 12 TO 16 23 TO 27 34 TO 38 45 TO 49&lt;br /&gt;UNB 4 MEMB 6 11 17 22 28 33 39 44&lt;br /&gt;UNT 4 MEMB 6 11 17 22 28 33 39 44&lt;br /&gt;UNB 1 MEMB 7 TO 10 18 TO 21 29 TO 32 40 TO 43&lt;br /&gt;UNT 1 MEMB 7 TO 10 18 TO 21 29 TO 32 40 TO 43&lt;br /&gt;CHECK CODE ALL&lt;br /&gt;FINISH&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question II</title><link>https://communities.bentley.com/achievements/cd3cd235-25c1-476e-bb88-33a5705ca45a</link><pubDate>Mon, 27 Sep 2021 02:03:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7e57e260-884a-496d-b6dd-e1c9d942f23e</guid><dc:creator /><description>Ask 10 questions in a forum.</description></item><item><title>+Fy restraint support</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/111687/fy-restraint-support</link><pubDate>Tue, 29 Sep 2015 05:02:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0b910b19-8c09-4de3-af54-a9847b18bd22</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;Dear Engineers,&lt;/p&gt;
&lt;p&gt;Is it possible to create +Fy restraint support in STAAD?&lt;/p&gt;
&lt;p&gt;When I use&lt;/p&gt;
&lt;p&gt;FIXED BUT FX FZ MX MY MZ&amp;nbsp;&lt;/p&gt;
&lt;p&gt;It restraint in both +Fy and -Fy&lt;/p&gt;
&lt;p&gt;My condition is simple rest support. Only +Fy restraint and -Fy is free&lt;/p&gt;
&lt;p&gt;Is it possible to create such a support in STAAD?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Modelling with member offset and without- which one is correct</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/77232/modelling-with-member-offset-and-without--which-one-is-correct</link><pubDate>Sat, 16 May 2015 08:31:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6c5efbb6-6b8b-40a4-8f78-daa8f672f38a</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;Generally in STAAD Pro we model by connecting centre to centre nodes. Like this...&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " border="0" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Discussions-Components-Files/5932/5327.noof.JPG" /&gt;&lt;/p&gt;
&lt;p&gt;But actual will be different from the above. We can use the member offset option to do like real model.&amp;nbsp; But most of us not doing member offset. Is that correct way of modeling?&amp;nbsp; There is a big difference in reaction between with member offset command and without member offset command.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " border="0" src="/resized-image.ashx/__size/550x0/__key/CommunityServer-Discussions-Components-Files/5932/5430.off.JPG" /&gt;&lt;/p&gt;
&lt;p&gt;Which way of modeling is correct&amp;hellip;!&lt;/p&gt;
&lt;p&gt;With member offset and without member offset ...?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Rebar placement in RCC rectangular water Tank</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/103306/rebar-placement-in-rcc-rectangular-water-tank</link><pubDate>Tue, 16 Dec 2014 07:05:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3f174357-6575-44b7-93e7-ccb5aaf73248</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;Dear Engineers,&lt;/p&gt;
&lt;p&gt;Im detailing RCC rectangular water Tank.&lt;/p&gt;
&lt;p&gt;Got the ast and Rebar details.&lt;/p&gt;
&lt;p&gt;Could you pls. &amp;nbsp;clarify which way of rebar placement is correct among the below(Section A or B).&lt;/p&gt;
&lt;p&gt;i.e in Tank Wall the vertical reinforcement bar will come inside or outside of the horizontal reinforcement&amp;nbsp;bar?&lt;/p&gt;
&lt;p&gt;In circular tanks vertical&amp;nbsp;reinforcement will come in side the horizontal&amp;nbsp;reinforcement . In Rectangular tanks ?&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/5932/REBAR.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-discussions-components-files/5932/REBAR.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>STAAD-Unable to apply Wind load for cooling tower(Structure with only plates)</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/77043/staad-unable-to-apply-wind-load-for-cooling-tower-structure-with-only-plates</link><pubDate>Mon, 12 Mar 2018 17:03:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:075b1742-b8b2-41bd-bf6f-0cbcfbfc3b7a</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;Why Unable to apply Wind load for cooling tower kind of structure. i.e Structure with only plates&amp;nbsp;or surfaces.&lt;/p&gt;
&lt;p&gt;Error Shows :&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&amp;nbsp; **ERROR NO MEMBERS IN RANGE IN WIND LOAD.&lt;/p&gt;
&lt;p&gt;Practically there won&amp;#39;t be beams or column members in such a structure.&lt;/p&gt;
&lt;p&gt;Is there any other way to apply wind load for this type of structures.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Discussion Starter I</title><link>https://communities.bentley.com/achievements/21025ab1-febb-4fb4-a872-d32a921cb45c</link><pubDate>Mon, 12 Mar 2018 09:08:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:99c37afd-f434-4052-8574-f185e3b18f74</guid><dc:creator /><description>Start a discussion in a forum that receives 5 replies.</description></item><item><title>Temperature load in STAAD (Thermal load of steel )</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/115660/temperature-load-in-staad-thermal-load-of-steel</link><pubDate>Tue, 02 Feb 2016 10:40:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5425d152-8026-4b44-903a-d94f7350aa40</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;Dear Engineers,&lt;/p&gt;
&lt;p&gt;Im analysing a steel structure where I have to apply thermal load. below are the datas.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Max. Temp 45 deg&amp;nbsp;Celsius&lt;/li&gt;
&lt;li&gt;Min.Temp -35 deg Celsius&lt;/li&gt;
&lt;li&gt;Site&amp;nbsp;Average maximum temperature : 36&amp;deg;C&lt;/li&gt;
&lt;li&gt;Site&amp;nbsp;Average minimum temperature : -22&amp;deg;C&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;In STAAD we have below 3 things in the input cell. How to calculate this from the above input.&lt;/p&gt;
&lt;p&gt;Temperature Change for Axial Elongation&lt;/p&gt;
&lt;p&gt;Temperature Differential from Top to Bottom&lt;/p&gt;
&lt;p&gt;Temperature Differential from side to side&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>deflection in z direction</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/136080/deflection-in-z-direction</link><pubDate>Tue, 09 May 2017 08:22:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f0457487-0a97-467e-8658-b76fcc8fa7e9</guid><dc:creator>eng_ahmed</dc:creator><description>&lt;p&gt;i have side girt c channel in steel building and it is affected with dead load acting on it&amp;#39;s weak axis as shown&lt;/p&gt;
&lt;p&gt;i want to know the deflection in z direction due to dead load (staad only show deflection in y direction ) ,i add &amp;nbsp;staad file&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/5932/7041.1.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-discussions-components-files/5932/7041.1.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;STAAD SPACE&lt;br /&gt;START JOB INFORMATION&lt;br /&gt;ENGINEER DATE 05-Mar-17&lt;br /&gt;END JOB INFORMATION&lt;br /&gt;INPUT WIDTH 79&lt;br /&gt;UNIT METER KN&lt;br /&gt;JOINT COORDINATES&lt;br /&gt;11 -5 4.2 0; 12 1.5 4.2 0; 13 1.475 12.4 0; 14 -5 12.4 0;&lt;br /&gt;MEMBER INCIDENCES&lt;br /&gt;5 11 12; 6 13 14;&lt;br /&gt;*START GROUP DEFINITION&lt;br /&gt;*JOINT&lt;br /&gt;*END GROUP DEFINITION&lt;br /&gt;DEFINE MATERIAL START&lt;br /&gt;ISOTROPIC STEEL&lt;br /&gt;E 2.05e+008&lt;br /&gt;POISSON 0.3&lt;br /&gt;DENSITY 76.8195&lt;br /&gt;ALPHA 1.2e-005&lt;br /&gt;DAMP 0.03&lt;br /&gt;TYPE STEEL&lt;br /&gt;STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2&lt;br /&gt;END DEFINE MATERIAL&lt;br /&gt;MEMBER PROPERTY COLDFORMED AMERICAN&lt;br /&gt;6 TABLE ST JWE8X102CS&lt;br /&gt;MEMBER PROPERTY AMERICAN&lt;br /&gt;5 TABLE ST C6X8&lt;br /&gt;CONSTANTS&lt;br /&gt;MATERIAL STEEL ALL&lt;br /&gt;SUPPORTS&lt;br /&gt;11 TO 14 PINNED&lt;br /&gt;LOAD 1 LOADTYPE Dead TITLE DL&lt;br /&gt;SELFWEIGHT Y -1 &lt;br /&gt;MEMBER LOAD&lt;br /&gt;*for vertical studs&lt;br /&gt;*for purlins&lt;br /&gt;6 UNI Y -0.14&lt;br /&gt;*for horizontal studs in walls&lt;br /&gt;*for horizontal studs with span 3.5m in walls&lt;br /&gt;5 UNI GZ 0.22&lt;br /&gt;LOAD 2 LOADTYPE Live TITLE LL&lt;br /&gt;MEMBER LOAD&lt;br /&gt;6 UNI Y -1.17&lt;br /&gt;LOAD 3 LOADTYPE Wind TITLE WLZ&lt;br /&gt;MEMBER LOAD&lt;br /&gt;5 UNI Y -0.92&lt;br /&gt;6 UNI Y 1.68&lt;br /&gt;LOAD COMB 4 COMBINATION LOAD CASE 4&lt;br /&gt;1 1.0 2 1.0 &lt;br /&gt;LOAD COMB 5 0.6DL+LL&lt;br /&gt;1 0.6 2 1.0 &lt;br /&gt;LOAD COMB 6 0.6D+WL&lt;br /&gt;1 0.6 3 1.0 &lt;br /&gt;PERFORM ANALYSIS&lt;br /&gt;*spacing for 1 meters&lt;br /&gt;PARAMETER 1&lt;br /&gt;CODE AISI&lt;br /&gt;BEAM 1 MEMB 5&lt;br /&gt;FLX 1 ALL&lt;br /&gt;LT 0.3 ALL&lt;br /&gt;LY 1.9 MEMB 5&lt;br /&gt;LY 3.25 MEMB 6&lt;br /&gt;CHECK CODE MEMB 6&lt;br /&gt;PERFORM ANALYSIS&lt;br /&gt;*spacing for 2 meters&lt;br /&gt;PARAMETER 2&lt;br /&gt;CODE AISC UNIFIED 2005&lt;br /&gt;METHOD ASD&lt;br /&gt;FYLD 248213 MEMB 5&lt;br /&gt;CB 1 MEMB 5&lt;br /&gt;DFF 0.027 MEMB 5&lt;br /&gt;DJ2 14 MEMB 5&lt;br /&gt;DJ1 13 MEMB 5&lt;br /&gt;BEAM 1 MEMB 5&lt;br /&gt;LZ 2.875 MEMB 5&lt;br /&gt;LY 2.875 MEMB 5&lt;br /&gt;UNT 0.3 MEMB 5&lt;br /&gt;CHECK CODE MEMB 5&lt;br /&gt;STEEL MEMBER TAKE OFF LIST 5&lt;br /&gt;PERFORM ANALYSIS&lt;br /&gt;FINISH&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Water Tank Design</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/96614/water-tank-design</link><pubDate>Fri, 25 Apr 2014 09:10:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9baa92dd-1961-4f38-a89f-dd0bf9c0f087</guid><dc:creator>vivekshine</dc:creator><description>&lt;p&gt;Dear Engineers,&lt;/p&gt;
&lt;p&gt;Im designing Square Steel water tank using STAAD. I have few doubt. pls. &amp;nbsp;clarify if u have could... Thanks in advance.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;1) say the size is 3m x 3m x 2m&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Hence volume = 18m3&lt;/p&gt;
&lt;p&gt;Weight of water =18*1000 = 18000kg&lt;/p&gt;
&lt;p&gt;Pressure on bottom of the tank will be 2000kg/m2&lt;/p&gt;
&lt;p&gt;How to calculate the pressure on side wall of the tank&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-discussions-components-files/5932/3580.Untitled.png"&gt;&lt;img src="/resized-image.ashx/__size/550x0/__key/communityserver-discussions-components-files/5932/4571.3580.Untitled.png" border="0" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;2) When there are so many stress result is shown in post-processing . Which stress do we need to consider for design. Is max Absolute &amp;nbsp;ok?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-discussions-components-files/5932/4645.Untitled.png"&gt;&lt;img src="/resized-image.ashx/__size/550x0/__key/communityserver-discussions-components-files/5932/7711.4645.Untitled.png" border="0" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>UNT and UNB AISC 2010</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/128528/unt-and-unb-aisc-2010</link><pubDate>Wed, 16 Nov 2016 19:56:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:577ea3f1-88b9-4885-8d70-dbe86477db34</guid><dc:creator>Jorge Ochoa Le&amp;#243;n</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;Do I &amp;nbsp;have to use the command UNT either UNB for beams that already have lateral support as show in the picture (selected)?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/5932/UNT_5F00_UNB.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-discussions-components-files/5932/UNT_5F00_UNB.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:&amp;#39;Source Sans Pro&amp;#39;, Helvetica, Arial, sans-serif;font-size:16px;background-color:#ffffff;"&gt;Thanks!&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Problem with DFF command not check  in steel design with STAAD Pro SS6  built  20071150 (Latest built)</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/115802/problem-with-dff-command-not-check-in-steel-design-with-staad-pro-ss6-built-20071150-latest-built</link><pubDate>Sat, 06 Feb 2016 04:20:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3e5b3d44-e63a-4ac3-a0e6-80efd52ee3ed</guid><dc:creator>siwalak khamnurak</dc:creator><description>&lt;p&gt;Please see STAAD input command below. I try to change DFF parameter in any value (not 0) but the result still show all member pass all code check.&lt;/p&gt;
&lt;p&gt;Please verify if I&amp;#39;m wrong...&lt;/p&gt;
&lt;p&gt;Best regard.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;STAAD SPACE&lt;br /&gt;START JOB INFORMATION&lt;br /&gt;ENGINEER DATE 06-Feb-16&lt;br /&gt;END JOB INFORMATION&lt;br /&gt;INPUT WIDTH 79&lt;br /&gt;UNIT METER KG&lt;br /&gt;JOINT COORDINATES&lt;br /&gt;1 0 5 0; 2 10 5 0; 3 0 4.91 1.7; 4 10 4.91 1.7; 5 0 4.93656 1.19832;&lt;br /&gt;6 10 4.93656 1.19832; 7 0 3.8 0; 8 10 3.8 0; 9 0 4.99207 0.14979;&lt;br /&gt;10 10 4.99207 0.14979; 11 0 4.9511 0.923706; 12 10 4.9511 0.923706;&lt;br /&gt;MEMBER INCIDENCES&lt;br /&gt;1 1 9; 2 2 10; 3 3 4; 4 5 3; 5 6 4; 6 7 5; 7 8 6; 8 9 11; 9 10 12; 10 9 10;&lt;br /&gt;11 11 5; 12 12 6; 13 11 12;&lt;br /&gt;START GROUP DEFINITION&lt;br /&gt;FLOOR&lt;br /&gt;_CP1 3 TO 5 8 TO 13&lt;br /&gt;END GROUP DEFINITION&lt;br /&gt;DEFINE MATERIAL START&lt;br /&gt;ISOTROPIC STEEL&lt;br /&gt;E 2.09042e+010&lt;br /&gt;POISSON 0.3&lt;br /&gt;DENSITY 7833.41&lt;br /&gt;ALPHA 1.2e-005&lt;br /&gt;DAMP 0.03&lt;br /&gt;TYPE STEEL&lt;br /&gt;STRENGTH FY 2.58192e+007 FU 4.1584e+007 RY 1.5 RT 1.2&lt;br /&gt;END DEFINE MATERIAL&lt;br /&gt;MEMBER PROPERTY JAPANESE&lt;br /&gt;1 2 4 5 8 9 11 12 TABLE ST C150X75X9&lt;br /&gt;3 10 13 TABLE ST RHS150X75X2.3&lt;br /&gt;6 7 TABLE ST C100X50X5&lt;br /&gt;CONSTANTS&lt;br /&gt;BETA 180 MEMB 2 5 7 9 12&lt;br /&gt;MATERIAL STEEL ALL&lt;br /&gt;SUPPORTS&lt;br /&gt;1 2 7 8 PINNED&lt;br /&gt;LOAD 1 LOADTYPE None TITLE DL&lt;br /&gt;SELFWEIGHT Y -1 &lt;br /&gt;FLOOR LOAD&lt;br /&gt;_CP1 FLOAD -10 GY&lt;br /&gt;LOAD 2 LOADTYPE None TITLE LR&lt;br /&gt;FLOOR LOAD&lt;br /&gt;_CP1 FLOAD -30 GY&lt;br /&gt;LOAD 3 LOADTYPE None TITLE WX&lt;br /&gt;FLOOR LOAD&lt;br /&gt;_CP1 FLOAD 50 GY&lt;br /&gt;LOAD 4 LOADTYPE None TITLE WZ&lt;br /&gt;FLOOR LOAD&lt;br /&gt;_CP1 FLOAD 70 GY&lt;br /&gt;LOAD COMB 101 DL+LR&lt;br /&gt;1 1.0 2 1.0 &lt;br /&gt;LOAD COMB 102 DL+0.75[LR+WX]&lt;br /&gt;1 1.0 2 0.75 3 0.75 &lt;br /&gt;LOAD COMB 103 DL+0.75[LR+WZ]&lt;br /&gt;1 1.0 2 0.75 4 0.75&lt;br /&gt;LOAD COMB 104 DL+WX&lt;br /&gt;1 1.0 3 1.0 &lt;br /&gt;LOAD COMB 105 DL+WZ&lt;br /&gt;1 1.0 4 1.0 &lt;br /&gt;LOAD COMB 106 0.6DL+WX&lt;br /&gt;1 0.6 3 1.0 &lt;br /&gt;LOAD COMB 107 0.6DL+WZ&lt;br /&gt;1 0.6 4 1.0 &lt;br /&gt;PERFORM ANALYSIS&lt;br /&gt;LOAD LIST 101 TO 107&lt;br /&gt;PARAMETER 1&lt;br /&gt;CODE AISC UNIFIED 2005&lt;br /&gt;METHOD ASD&lt;br /&gt;MAIN 1 MEMB 3 10 13&lt;br /&gt;TMAIN 1 MEMB 3 10 13&lt;br /&gt;*LY 5 MEMB 3 10 13&lt;br /&gt;DFF 1000 MEMB 3 10 13&lt;br /&gt;DJ1 9 MEMB 10&lt;br /&gt;DJ2 12 MEMB 10&lt;br /&gt;CHECK CODE ALL&lt;br /&gt;FINISH&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>