<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>PlaxisUser1's Communities Activities</title><link>https://communities.bentley.com/members/7d38328d_2d00_3e97_2d00_4be2_2d00_a129_2d00_98ee5472abc5</link><description>Recent activity for people in PlaxisUser1's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Pressuremeter Test Plaxis to estimate parameters</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/246079/pressuremeter-test-plaxis-to-estimate-parameters</link><pubDate>Fri, 02 Jun 2023 08:04:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d8d1e40-5d95-4d69-8c8c-942580d3934f</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;Plaxis does not include in the Soil Test tool the pressuremeter test. I have some pressuremeter tests resutls and I would like to estimate the geotechnical parameters from the soil with them.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;As the soil test tool does not have this test any idea? Could I do an axxysimterical model and apply a horizontal distributed increasing laod at the pressuremeter test depth in order to simulate the test?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind Regards&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Discontinuos Pile Wall in Plaxis 3D</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/248824/discontinuos-pile-wall-in-plaxis-3d</link><pubDate>Fri, 11 Aug 2023 05:26:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:165f08ee-c572-4383-a05c-653dc1e7feee</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;What is the best way to model a discontinuos pile wall in plaxis 3D for a braced excavation. As a plate with equivalent EI? as a volume element? or as embedded beam elements&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;If I do it as I plate as they are 1,2m piles with a separation of 1.5m between pile centers the stiffness parameters should be different in &amp;quot;1&amp;quot; and &amp;quot;2&amp;quot; directions&amp;quot; no?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind Regards&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Pseudostatic model and Fixed End Anchors vs Beams (Braced Excavations)</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/248583/pseudostatic-model-and-fixed-end-anchors-vs-beams-braced-excavations</link><pubDate>Mon, 07 Aug 2023 06:01:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e9ef5747-38dd-4751-8188-84a1ca70aae4</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;Hi&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I am running pseudostatic models for braced simmetric excavation models with Fixed End Anchors or beams. With static conditions I have no problems and I having the same resutls as for fixed anchors the point with 0 deformation is at the middle of the strut.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;When I run pseudostatic models with beams the results that seem to be ok.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;However if instead of beams I use fixed end anchors I have to divide the stiffness by a huge number in order to obtain the same result. I guess that this is because the program is assuming that the fixed point is at the middle of the strut length and therefore I need to increase this length by a big number or reduce the stiffness as in dynamic hipothesis the point at the middle of the strut is going to have a displacements and not 0 like in a simmetric braced excavation.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Many THanks&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind Regards&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Discontinuos Retaining Wall Plaxis 3D as a Plate</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/248354/discontinuos-retaining-wall-plaxis-3d-as-a-plate</link><pubDate>Tue, 01 Aug 2023 06:22:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8c3ccf74-7cab-4906-8780-595e53ed9ab3</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I am modelling in Plaxis 3D a discontinuos Pile Wall as a Plate.&amp;nbsp; I have my EA and EI per meter of model of my retaining wall so I am adjusting the EI value of my 3D plate to my former EI value. When I adjust EI I have some differences in my EA value as my original retaining wall is not a rectangular diaphram wall. However should I model it as isotropic or not?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind Regards&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Discussion Starter I</title><link>https://communities.bentley.com/achievements/21025ab1-febb-4fb4-a872-d32a921cb45c</link><pubDate>Tue, 04 Jul 2023 19:55:01 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0369e367-ba45-4a8b-a8e4-c371399a8e10</guid><dc:creator /><description>Start a discussion in a forum that receives 5 replies.</description></item><item><title>Dimensions of braced excavation model with pseudostatic analysis</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/247259/dimensions-of-braced-excavation-model-with-pseudostatic-analysis</link><pubDate>Tue, 04 Jul 2023 12:32:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc61ad9d-4a29-4c8f-9412-a0ba49854972</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;Any guidance on which width should I put to my pseudostatic model for a braced excavation of 20m width , 30m piles and 20m of excavation depth?&lt;/p&gt;
&lt;p&gt;Depending on the width of the model the forces change in my&lt;span style="font-family:inherit;"&gt;&amp;nbsp;structural elements so I dont know which width should I put to my model.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;Thanks!!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Long Term Stiffness Retaining Wall</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/247216/long-term-stiffness-retaining-wall</link><pubDate>Mon, 03 Jul 2023 08:09:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f4064f29-8852-4520-9a45-b088de41f5da</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;CIRIA 760 recommends to use a 0.5EI for short term stiffness (EI) and 0,7EI for long term stiffness (EI) for retaining walls.&lt;/p&gt;
&lt;p&gt;Should I also reduce the term EA?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Any other reference aside from CIRIA?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Pseudostatic Analysis Simmetric Braced Excavation</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/246439/pseudostatic-analysis-simmetric-braced-excavation</link><pubDate>Tue, 13 Jun 2023 08:58:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d25c6e35-ae7b-46b9-a210-fd0447a1de31</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;I am using Plaxis 2D to model a braced excavation with struts. For the static condition I have done only half of the model (one side of the excavation) as it is a simmetric excavation.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;However for the seismic condition in which I have to use a pseudostatic force can I also only model half of the model? Or would&amp;nbsp;I need to model the two sides of the excavation?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks guys&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Rigid Inclusions Webinar On Demand</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/244472/rigid-inclusions-webinar-on-demand</link><pubDate>Fri, 21 Apr 2023 06:02:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:14ec3843-80d2-4433-bb2c-de2155994f37</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;Where could I watch the webinar which took place this week? I was not able to watch it completely ? Any link?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind Regards&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Mon, 10 Apr 2023 02:55:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c09bc56a-8764-46dd-bfc0-ffe98a7dafe2</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>Moment as two external forces or applied as Mx/My</title><link>https://communities.bentley.com/products/geotech-analysis/f/forum/243983/moment-as-two-external-forces-or-applied-as-mx-my</link><pubDate>Mon, 10 Apr 2023 12:16:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:324f6efa-ec70-4ac2-96f7-4ac050039146</guid><dc:creator>PlaxisUser1</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I have a footing modelled as a metrial in which I have an external Mx/My Moment.&lt;/p&gt;
&lt;p&gt;If I apply the Moment as two opposite vertical forces -Fz and +Fz at a distance of 1m from the footing center the result is different that if I apply the moment Mx/My at the footing centre. With this last option the footing is not turning so I dont know why applying the moment directly does not works&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/343671/pastedimage1681129113127v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;E.g if I have a moment of 100.000 kN.m I would apply the two opposite vertical forces of +-50000 kN at a distance of +-1m from the footing centre.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind Regards&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>