<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>GL's Communities Activities</title><link>https://communities.bentley.com/members/80c5620e_2d00_6b66_2d00_44be_2d00_ac1f_2d00_efd2349d0ba9</link><description>Recent activity for people in GL's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Room not found in design database</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/145117/room-not-found-in-design-database</link><pubDate>Wed, 03 Jan 2018 12:11:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:50696aac-342d-4d8e-9e57-a4a9ae27f16e</guid><dc:creator>Claire Mackenzie</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I&amp;#39;m currently working on a model and have deleted a room, however, the following message has came up... &amp;quot;room not found in database. To prevent possible database corruption design database will now shut down&amp;quot; and the project is now inaccessible. This is causing a major problem as I have taken the model quite far and now I cant access it. Can this problem be resolved without having to start again?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Kind regards,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Claire Mackenzie&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Unable to open file</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/225978/unable-to-open-file</link><pubDate>Thu, 17 Feb 2022 15:49:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2b4886b2-666f-402b-b2b3-7cb6e74b0ff8</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Please could you be able to help me open Netsys heating file. Below message pops up while trying to open.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1645112948267v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Regards&amp;nbsp;&lt;/p&gt;
&lt;p&gt;GL&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Hevacomp Installation Windows 10</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/224313/hevacomp-installation-windows-10</link><pubDate>Fri, 07 Jan 2022 15:10:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1baffc72-b527-4b01-89ae-41c9229e1e90</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I am having issue with Hevacomp installation/launching on my PC. For your reference below is my PC built. Please could you confirm if the PC is compatible and clarify what could be the issue and suggest a step wise guide to the latest Hevacomp Software installation Including add-ons for report generation.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1641568127762v4.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1641567670979v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1641567737961v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Many Thanks&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Regards&amp;nbsp;&lt;/p&gt;
&lt;p&gt;GL&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Dimension of duct not as fixed size.</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/185624/dimension-of-duct-not-as-fixed-size</link><pubDate>Mon, 16 Sep 2019 12:25:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:55cb7902-e3d9-48d2-8f63-95074ee988e4</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Please could you be able to help me with below. I have&amp;nbsp;fixed&amp;nbsp;the duct size as below, however on layout the width is shown as height and height as width. How do I amend this? Thanks&amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1568636565444v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Room Not Found in Database</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/183768/room-not-found-in-database</link><pubDate>Thu, 08 Aug 2019 15:08:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a6a09c36-8e2a-4000-b8f9-c7eba2cd8b7c</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I am unable to open load calculation file and below notification pops up. please could anyone help me to fix this issue.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1565276915227v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Many Thanks&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question II</title><link>https://communities.bentley.com/achievements/cd3cd235-25c1-476e-bb88-33a5705ca45a</link><pubDate>Thu, 08 Aug 2019 15:09:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:94217658-20a9-418d-a483-fea5fd796ccd</guid><dc:creator /><description>Ask 10 questions in a forum.</description></item><item><title>Internal Heat Gain</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/183691/internal-heat-gain</link><pubDate>Wed, 07 Aug 2019 14:27:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:970f8cd5-eea7-4388-ad7e-e6c5d7460d1e</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;On Design Database I have specified body sensible and latent heat gain as below; however on room data sheet causal gain only picks up casual w/m^2 which is 0. Can you confirm if the heat gain from occupied body is taken into account as specified below.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1565187720668v3.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Regards GL&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>K VALUE FOR DEFAULT BENDS AND TEES</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/178280/k-value-for-default-bends-and-tees</link><pubDate>Tue, 16 Apr 2019 09:34:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ca6ea74d-0b6a-43ef-87df-891b9970715d</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&lt;/p&gt;
&lt;p&gt;Understood the below links gives K-value for some of the fitting however, it doesn&amp;#39;t show the assumed value for different default bends and tees . Please could you be able to post the k vale for the default connection fittings. i want to verify the pressure loss is correct and is inline with CIBSE guide C.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/products/building/performance/w/building_performance__wiki/17605/pipe-and-duct-fittings-k-values"&gt;https://communities.bentley.com/products/building/performance/w/building_performance__wiki/17605/pipe-and-duct-fittings-k-values&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Many Thanks&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Regards&amp;nbsp;&lt;/p&gt;
&lt;p&gt;GL&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>SHOW PUMP DUTY RESULT HWS</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/179193/show-pump-duty-result-hws</link><pubDate>Tue, 07 May 2019 12:27:21 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:99adf439-d40e-40b9-9235-ae015f956be6</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;HI&amp;nbsp;&lt;/p&gt;
&lt;p&gt;ALTHOUGH I HAVE SELECTED &amp;quot;SHOW PUMP DUTY RESULT&amp;quot; THE SOFTWARE DOES NOT DISPLAY IT. PLEASE COULD YOU CLARIFY WHY IS THIS&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1557231981977v2.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CWS PD/METER</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/178859/cws-pd-meter</link><pubDate>Mon, 29 Apr 2019 14:13:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4c85060a-db7e-411a-b6ae-34e1154ddeaa</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;HI&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;IS IT POSSIBLE TO DEFINE CWS SYSTEM WITH MAX&amp;nbsp; 250PD/METER. UNDERSTOOD THERE IS A WAY TO DEFINE MAX VELOCITY, HOWEVER AS THE VELOCITY AND PIPE INCRIMINATE IS NON-LINEAR THE&amp;nbsp; SOFTWARE UNDER SIZES THE PIPE RESULTING IN HIGH PD PER METER.&amp;nbsp; PLEASE ADVICE IF THERE IS ALTERNATIVE WAY TO LIMIT PD/METER TO 250PA.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/275871/pastedimage1556546947236v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;REGARDS&amp;nbsp;&lt;/p&gt;
&lt;p&gt;GL&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CWS PRESSURE DROP PER METER</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/178705/cws-pressure-drop-per-meter</link><pubDate>Thu, 25 Apr 2019 13:52:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d10b0c49-06c0-4594-be02-a94778ab775a</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;HI&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I ASSUME LIKE IN DUCTWORK THE PRESSURE&amp;nbsp;DROP&amp;nbsp;PER METER INCLUDES MINOR LOSS IE FITTINGS. IN CWS PRESSURE DROP PER METER NOTE. IS THERE&amp;nbsp; A WAY WITHIN THE SYSTEM TO EXCLUDE THE PRESSURE DROP DUE TO FITTINGS.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;REGARDS&lt;/p&gt;
&lt;p&gt;GL&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>PIPE SIZE CHART CWS</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/178703/pipe-size-chart-cws</link><pubDate>Thu, 25 Apr 2019 13:08:55 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:54391d4b-837f-4dd4-89a8-4c62291dae9e</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;HI&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;PLEASE COULD YOU BE ABLE TO POST A PIPE SIZING CHART FOR COPPER USED IN&amp;nbsp;NETSYS CWS&amp;nbsp;AS I FIND IT DIFFERENT FROM THE ONE IN BS 8558:2015.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;REGARDS&amp;nbsp;&lt;/p&gt;
&lt;p&gt;GL&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>MODELLING OF DUCT PASSING THROUGH RISER AT 45 DEGREE.</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/177974/modelling-of-duct-passing-through-riser-at-45-degree</link><pubDate>Wed, 10 Apr 2019 08:48:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3ffc6a53-3c62-41a7-b25c-c98d4a2bcfcc</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;HI&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I&amp;nbsp;HAVE A&amp;nbsp;DUCT PASSING VIA RISER FROM&amp;nbsp; L1 TO L6 AT AN ANGLE OF 45 DEGREE OR SAY NOT IN A 90 DEGREE&amp;nbsp;VERTICAL WAY.&amp;nbsp; PLEASE COULD YOU BE SO KIND TO DEMONSTRATE HOW THIS CAN BE MODELED.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;MANY THANKS&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Netsys Duct at different height on same floor connection.</title><link>https://communities.bentley.com/products/building/performance/f/hevacomp-forum/177675/netsys-duct-at-different-height-on-same-floor-connection</link><pubDate>Thu, 04 Apr 2019 08:30:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f6e02220-021e-460d-9494-9d634d4ab91a</guid><dc:creator>GL</dc:creator><description>&lt;p&gt;Hi&amp;nbsp;&lt;/p&gt;
&lt;p&gt;This is my first project in Netsys Ductwork Please could you be able to answer below questions&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;1) If&amp;nbsp; you have &amp;nbsp;two ducts at same height level&amp;nbsp; and inter-crosses how do you&amp;nbsp; design bends to avoid collision?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;2) How do you model branching duct at different height level from the main duct line?&lt;/p&gt;
&lt;p&gt;3) What does this fitting do Depression down, depression up, offset down &amp;amp; offset up?&lt;/p&gt;
&lt;p&gt;4) Connecting duct and diffuser to plenum box, it does not appear as connected. Appears as only duct and diffuser are connected. Is there a particular method for connecting all three?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Many Thanks&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Mon, 11 Feb 2019 01:12:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:43fb01d7-1c99-488a-ae4a-c310419f2e6d</guid><dc:creator /><description>Ask a question in a forum.</description></item></channel></rss>