<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Jen Park's Activities</title><link>https://communities.bentley.com/members/878ddad7_2d00_1c96_2d00_419d_2d00_a45f_2d00_681082235207</link><description>Jen Park's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Ram Steel Column: Can&amp;#39;t turn off skip loading</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/200814/ram-steel-column-can-t-turn-off-skip-loading</link><pubDate>Thu, 23 Jul 2020 21:30:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:de3f8d29-97f3-4a15-b559-d0a6c558696b</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;In RAM Steel Column, when I turn off the Skip-load the Live Load around column, it still shows skip load case as a controlling axial load in the report.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1595540163189v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1595540152653v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question II</title><link>https://communities.bentley.com/achievements/cd3cd235-25c1-476e-bb88-33a5705ca45a</link><pubDate>Thu, 23 Jul 2020 01:51:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a0e464c9-f295-40ff-b23a-caf258b29f53</guid><dc:creator /><description>Ask 10 questions in a forum.</description></item><item><title>RAM Foundation - Encountered Improper Argument</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/199437/ram-foundation---encountered-improper-argument</link><pubDate>Thu, 25 Jun 2020 21:44:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:76ab3d47-01d2-4f9b-8294-1c968cbe1528</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;In RAM Foundation, when I run the analysis, it shows a pop up that says &amp;quot;Encountered an Improper argument&amp;quot;&amp;nbsp; and some wall footings resullts show &amp;quot;ERROR: zero diagonal found in FEA due to modeal instability.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/20200625_5F00_1736.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/20200625_5F00_1743.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Structural Systems - Hovering over icons show symbols instead of menu item names</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/199435/ram-structural-systems---hovering-over-icons-show-symbols-instead-of-menu-item-names</link><pubDate>Thu, 25 Jun 2020 21:18:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:496c09d9-b629-459a-accc-b724e1a3a1d0</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;in RAM Structural Systems, when I hover over a button, the item name comes up, but I can&amp;#39;t read it because it is in symbols.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/20200625_5F00_1712.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/20200625_5F00_1711.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/20200625_5F00_1712.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Connection client has updates but fails to download or install.</title><link>https://communities.bentley.com/communities/other_communities/licensing_cloud_and_web_services/f/forum/181554/connection-client-has-updates-but-fails-to-download-or-install</link><pubDate>Mon, 24 Jun 2019 15:56:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b90a2ab1-74a5-4e87-861d-4519f16207e5</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;This has been going on for awhile at my company.&amp;nbsp; Client connection has updates, but when I click on it to download and install, it says &amp;quot;installation cancelled&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343368/4431.pastedimage1561392658608v1.png" /&gt;&lt;/p&gt;
&lt;p&gt;I am not an administrator for the computer so a pop up comes up to log in, and I log in using an administrator&amp;#39;s login, but it still fails.&amp;nbsp; I also&amp;nbsp;checked my BentleyDownloads folder, but it did not download.&lt;/p&gt;
&lt;p&gt;Here&amp;#39;s the link to my log:&amp;nbsp;&lt;a href="https://www.dropbox.com/s/ijf63b2p2hj1d13/Bentley.Connect.Client.exe.log?dl=0"&gt;www.dropbox.com/.../Bentley.Connect.Client.exe.log&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Structural Systems - from Revit (ISM) - Incorrect Yield Strength</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/194793/ram-structural-systems---from-revit-ism---incorrect-yield-strength</link><pubDate>Wed, 01 Apr 2020 21:24:01 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e25f5044-23f9-4cea-bf92-0fa067c7f099</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I imported a revit model in to RAM structural systems via ISM and all the beams were assigned Fy = 30.02 ksi.&amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I corrected it in the RAM model, but how do I prevent this from happening?&amp;nbsp; I could not figure out the default Fy on either RAM or the Revit side.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Connection Custom Template File Location</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/194792/ram-connection-custom-template-file-location</link><pubDate>Wed, 01 Apr 2020 20:58:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5216edeb-04b7-4e96-8f27-9610b0ed79ce</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Is it possible to save the custom templates from RAM Connection?&amp;nbsp;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Connection Scaling Issue</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/190159/ram-connection-scaling-issue</link><pubDate>Wed, 18 Dec 2019 22:24:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:219eb5ef-5203-4e95-81aa-42b339cf009f</guid><dc:creator>Erick Roque</dc:creator><description>&lt;p&gt;When I try to run RAM Connection, once I have assigned and designed a base plate connection, the dimensions on my elements get scaled up by at least x12. As you can see in the picture attached, my column is a 5x5x3/8 HSS Tube, and my base plate dimensions are 120&amp;quot; x 90&amp;quot;. When I try to modify the base plate to reasonable dimensions, the connection becomes miniscule in the graphic model compared to the rest of my frame elements. It is also to be noted that before loading the Connection module, an Errror pops up. I followed the following link to troubleshoot it, but I was not able to save the file. The second picture shows the &amp;quot;Save as type&amp;quot; drop down empty.&lt;/p&gt;
&lt;p&gt;&lt;a href="/products/ram-staad/w/structural_analysis_and_design__wiki/44966/access-violation---ram-connection-for-ram-ss-17"&gt;https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/44966/access-violation---ram-connection-for-ram-ss-17&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1576707816964v2.png" /&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1576707893629v3.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Elements 2D analysis Instability in Rx because of release conditions</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/186791/ram-elements-2d-analysis-instability-in-rx-because-of-release-conditions</link><pubDate>Thu, 10 Oct 2019 15:48:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:eb225834-fd20-490a-b363-cd762ffdccac</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;When I use RAM Elements for a 2D analysis such as a beam or column, it says I have a local instability for Node 1 at DOF RX.&amp;nbsp; If I fix the node for RX, the warning goes away.&amp;nbsp; I have a couple questions regarding the boundary conditions.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;1. Is RX torsion in this case?&lt;/p&gt;
&lt;p&gt;2.&amp;nbsp;In this case, since I only have 1 member, does the member hinge conditions do anything?&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/1289x480/__key/communityserver-discussions-components-files/5932/2019_2D00_10_2D00_10_5F00_12h00_5F00_57.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Connections W-Beam to HSS Column Limit</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/186184/ram-connections-w-beam-to-hss-column-limit</link><pubDate>Thu, 26 Sep 2019 16:40:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:32cbaad9-7285-477a-9baa-e8e61c7418f9</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Can RAM Connections design any of the following for BCF connections?&lt;/p&gt;
&lt;p&gt;I understand you cannot use HSS beams or columns for MA or US connections.&amp;nbsp; However, a seated moment connection is common for HSS moment connections and I am trying to create an all welded seated connection with flange plate on top.&amp;nbsp; These are my limitations/questions.&lt;/p&gt;
&lt;p&gt;&lt;span&gt;-&amp;nbsp;MA All Welded - Can you make it so that you are welding to the column, not bolted?&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;-&amp;nbsp;US All Welded -&amp;nbsp;&lt;span&gt;Can you make it so that you are welding to the&amp;nbsp;beam for top angle?&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;-&amp;nbsp;&lt;span&gt;US Welded to&amp;nbsp;Beam - Can you change where you are welding the seat to the beam like in MA connections for &amp;quot;full&amp;quot; vs &amp;quot;lateral&amp;quot;?&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;- Is it possible to change the top angle to a flange plate for MA or US connections?&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM Footing tension from moment from bottom of footing</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/174064/ram-footing-tension-from-moment-from-bottom-of-footing</link><pubDate>Tue, 22 Jan 2019 17:08:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:34feaa29-9181-46eb-89ba-ea57cb2e98c5</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I have a building with moment frames.&amp;nbsp; All lateral columns are fixed at the bottom and the pile caps keep failing with tension in the piles.&amp;nbsp; I pinned the columns at the bottom, thinking it will make it worse, and it actually all worked.&amp;nbsp; So the tension does not come from the coupled moment from the moment frame, but it comes from the bottom moment.&amp;nbsp; How does RAM calculate this, and wouldn&amp;#39;t the moment be resolved in the base plate connection and not in the piles?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Mon, 21 Jan 2019 01:09:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:44e31bfc-5c13-46f0-a68f-dbfb6ee63172</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>RAM Frame Moment Frame Reactions Output Signs</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/174001/ram-frame-moment-frame-reactions-output-signs</link><pubDate>Mon, 21 Jan 2019 23:27:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:77834037-ac4d-4212-b2ad-0e19e5a3fe57</guid><dc:creator>Jen Park</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Ram Frame axial load reactions output toggles + and - signs as shown.&amp;nbsp; Why is this happening and how come the signs don&amp;#39;t ever switch?&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/ram-frame-axial-output.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RAM CONNECTION MOMENT CONNECTION</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/156168/ram-connection-moment-connection</link><pubDate>Tue, 12 Jun 2018 23:12:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c8eb38c5-1f51-44fd-9b76-376e7190ca0d</guid><dc:creator>Iyad  Hammad</dc:creator><description>&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1528845098099v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;DEAR ALL,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;How is this connection supposed to carry moment when there is no weld on the beam side ? and still showing no errors ? and not able to add weld on beam side ?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>