<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Raphael :)'s Communities Activities</title><link>https://communities.bentley.com/members/8afeadcd_2d00_1cb6_2d00_44a4_2d00_b03c_2d00_240101f1c2d3</link><description>Recent activity for people in Raphael :)'s community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to create shape / associative region with pattern or hatch &amp;quot;without&amp;quot; border?</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/102347/how-to-create-shape-associative-region-with-pattern-or-hatch-without-border</link><pubDate>Wed, 05 Nov 2014 12:38:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4a3544ed-ff22-4b2a-83c5-81289436a026</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;In a few of our drawings I&amp;#39;ve found nice graphics I would like to reproduce in new drawings. &lt;br /&gt;It involves areas with hatching / Pattern, nothing magnificent but in a nice way to represent it.&lt;/p&gt;
&lt;p&gt;I would like to indicate surfaces by shading, but without to hatche the whole surface.&lt;br /&gt;I want to fill only a small section and what I like here is that this hatched area has no dedicated frame. &lt;br /&gt;This is a great way to indicate surfaces.&lt;/p&gt;
&lt;p&gt;How does this work?&lt;/p&gt;
&lt;p&gt;I have played around a lot without success.&lt;/p&gt;
&lt;p&gt;The only way, but without the same result was:&lt;br /&gt;- create a shape&lt;br /&gt;- hatch the shape (associative pattern not enabled)&lt;br /&gt;- delete the shape&lt;br /&gt;- group the hatch lines&lt;/p&gt;
&lt;p&gt;However I would create a hatches surface as &amp;quot;Associative Region without frame&amp;quot;.&lt;br /&gt;See the right shading on this picture&amp;nbsp;and the attached sample file.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/273/Bentley-Forum-_2D00_-Pattern-without-border.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/500x0/__key/communityserver-discussions-components-files/273/Bentley-Forum-_2D00_-Pattern-without-border.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/273/Bentley-Forum-_2D00_-pattern-without-border.dgn"&gt;communities.bentley.com/.../Bentley-Forum-_2D00_-pattern-without-border.dgn&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Thanks &lt;br /&gt;Regards &lt;br /&gt;Raphael&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Does anyone known this on-screen view popup?</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/215513/does-anyone-known-this-on-screen-view-popup</link><pubDate>Fri, 18 Jun 2021 11:52:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4478e0c0-c613-48a2-87b6-3dd2580b6f98</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hi,&lt;br /&gt;I found this picture on the internet, in a Microstation Connect documentation written by Stephen Holmes and Robert Jones.&amp;nbsp;(Peoples maybe also active here?)&lt;br /&gt;I find the change-view popup shown on the right very interesting, but it is not described in this documentation.&lt;br /&gt;I&amp;#39;ve tried a lot and googled afterwards, but unfortunately without success.&lt;br /&gt;Maybe someone knows whether this is an onboard function in Microstation or how to get this on-screen menu?&lt;br /&gt;Many thanks&lt;br /&gt;Regards&lt;br /&gt;Rapha&amp;euml;l&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/273/4214.Microstation-Connect-Edition-_2D00_-Stephen-Holmes-and-Robert-Jones-_2D00_-Foster-_2B00_-Partners.jpg" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>I can&amp;#39;t handle the elevation property.</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/215084/i-can-t-handle-the-elevation-property</link><pubDate>Wed, 09 Jun 2021 17:06:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e61d9556-9317-48f2-a49c-dfafe5f45ef5</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;For a special reason, I would like to draw a site plan in a 3D DGN instead of a 2D DGN, to be able to use the &amp;quot;elevation&amp;quot; element property.&lt;br /&gt;Normally we would draw this type of drawing in 2D, but in this case, I want to build this plan up in different &amp;quot;layers&amp;quot;.&lt;br /&gt;That means, each floor on a different elevation (Z-axis height).&lt;br /&gt;I was very pleased when I discovered the elevation property.... and thought that would be a great help to make my work easier.&lt;br /&gt;Unfortunately, however, I can&amp;#39;t handle this elevation property.&lt;/p&gt;
&lt;p&gt;It starts with the fact that there are differences between the V8iSS4 and the Connect Edition Update14, which I both use.&lt;br /&gt;In the V8iSS4, the elevation is displayed for certain objects in the property window, but the elevation values ​​cannot be changed.&lt;/p&gt;
&lt;p&gt;The other way, in the Connect Edition, I can change the elevation values ​​with the &amp;quot;Set Element Elevation&amp;quot; tool, but I don&amp;#39;t know how to display this value for elements ....&lt;br /&gt;In the Connect Edition, the point for the element elevation is missing...., this property can not be shown.&lt;/p&gt;
&lt;p&gt;I&amp;#39;m very confused about the elevation property and would be happy if you could help.&lt;/p&gt;
&lt;p&gt;1) Why does (in MSV8iSS4) the elevation property not exist for all type of elements?&lt;br /&gt;For example, if I draw a shape, the &amp;quot;elevation&amp;quot; property is shown in the property windows. But if I draw a simple line, it didn&amp;acute;t have.&lt;/p&gt;
&lt;p&gt;2) Why can I no longer see the elevation values ​​in the property window in the Connect Edition?&lt;br /&gt;How can I display these values?&lt;/p&gt;
&lt;p&gt;One optional question :)&lt;br /&gt;3) Is it possible to select elements at a specific elevation?&lt;/p&gt;
&lt;p&gt;I add 4 screen shots, with the difference between MSV8iSS4 and Connect Edition Update 14.&lt;/p&gt;
&lt;p&gt;Many Thanks&lt;br /&gt;Regards&lt;br /&gt;Raphael&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/273/MSV8iSS4-_2D00_-Line-_2D00_-missing-elevation-property.jpg" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/273/MSV8iSS4-_2D00_-Shape-_2D00_-elevation-property-exist.jpg" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/273/MSconnect14-_2D00_-Line-_2D00_-missing-elevation-property.jpg" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/273/MSconnect14-_2D00_-Shape-_2D00_-missing-elevation-property.jpg" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Discussion Starter I</title><link>https://communities.bentley.com/achievements/21025ab1-febb-4fb4-a872-d32a921cb45c</link><pubDate>Thu, 05 Nov 2020 07:37:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6b332483-d668-4b91-9320-d026d6813b5f</guid><dc:creator /><description>Start a discussion in a forum that receives 5 replies.</description></item><item><title>How to backup and restore Microstation Connect configuration to a new PC?</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/200853/how-to-backup-and-restore-microstation-connect-configuration-to-a-new-pc</link><pubDate>Fri, 24 Jul 2020 11:09:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a93e75bf-7994-49d3-8669-6cf0a0a7e046</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;For V8 version I found following posts, about how to backup and restore a microstation configuration to a new PC:&lt;/p&gt;
&lt;p&gt;&lt;a href="/products/microstation/w/microstation__wiki/8739/how-to-copy-user-preferences-and-user-configuration-files-to-a-new-or-different-pc"&gt;https://communities.bentley.com/products/microstation/w/microstation__wiki/8739/how-to-copy-user-preferences-and-user-configuration-files-to-a-new-or-different-pc&lt;br /&gt;&lt;/a&gt;&lt;a href="/products/microstation/w/microstation__wiki/8773/how-to-back-up-and-restore-user-preferences"&gt;https://communities.bentley.com/products/microstation/w/microstation__wiki/8773/how-to-back-up-and-restore-user-preferences&lt;/a&gt;&lt;a href="/products/microstation/w/microstation__wiki/8739/how-to-copy-user-preferences-and-user-configuration-files-to-a-new-or-different-pc"&gt;&lt;br /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Is there somewhere for the connect edition a guide which explains the best way on how to move to a new PC, with the need of reconfiguration as few as possible?&lt;/p&gt;
&lt;p&gt;Despite intensive search, I could not find any information about it.&lt;br /&gt;Many thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Microstation Connect - Rename personal.upf and personal.ucf</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/197026/microstation-connect---rename-personal-upf-and-personal-ucf</link><pubDate>Mon, 11 May 2020 19:03:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6a1e8b83-1557-42bb-b694-a6fccf30261f</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I just switched from V8i to Connect and would have a few questions, also among to a comment in the following text (hope I can link this here?):&lt;br /&gt;&lt;a href="https://envisioncad.com/microstation-connect-ucf-and-pcf-files/"&gt;https://envisioncad.com/microstation-connect-ucf-and-pcf-files/&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;- In the Connect Edition, the UPF and the UCF are now bound to the Microstation user and are called personal.upf and personal.ucf by default.&lt;br /&gt;I read in the linked text above, that there is still a configuration variable for the UPF file, but it wouldn&amp;#39;t work and you shouldn&amp;#39;t use it either ..... !?&lt;/p&gt;
&lt;p&gt;Is that correct?&lt;/p&gt;
&lt;p&gt;I would like, as in the past, to rename all of my personalized configuration files with my initials.&lt;br /&gt;E.g .: XY_UserPref.UPF and XY_UserConf.UCF&lt;br /&gt;I also found the variable for the UPF and was able to test it successfully. It seems to work for the UPF.&lt;/p&gt;
&lt;p&gt;- What about user-related UCF?&lt;br /&gt;How would I have to proceed to rename it?&amp;nbsp;Is that even possible?&lt;/p&gt;
&lt;p&gt;In msconfig.cfg (which we shouldn&amp;#39;t touch) I found:&lt;br /&gt;&lt;br /&gt;# ------------------------------------------------- ---------------------&lt;br /&gt;# The names of the user preference (.upf) and user configuration (.ucf) files,&lt;br /&gt;# which are stored in the $ (_ USTN_HOMEPREFS) directory, are determined by _USTN_USERNAME.&lt;br /&gt;# ------------------------------------------------- --------------------&lt;br /&gt;_USTN_USERNAME: Personal&lt;br /&gt;_USTN_PREFNAMEBASE: $ (_ USTN_HOMEPREFS) $ (_ USTN_USERNAME)&lt;br /&gt;# ------------------------------------------------- --------------------&lt;/p&gt;
&lt;p&gt;That means that the UPF and UCF always get this fixed name &amp;quot;Personal&amp;quot; via this variable ....&lt;br /&gt;But I still haven&amp;acute;t understood, how Microstation controll which UCF file has to be loaded, in order to refer to a renamed file.&lt;br /&gt;&lt;br /&gt;Please, can someone explain this?&lt;/p&gt;
&lt;p&gt;I would be happy if you could explain what the statement in the text linked above is based on and whether my plan for renaming this files is possible.&lt;/p&gt;
&lt;p&gt;Thanks a lot&lt;br /&gt;Regards&lt;br /&gt;Raphael&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>My thoughts and fears on using text styles in Border-Seed-Files.</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/142951/my-thoughts-and-fears-on-using-text-styles-in-border-seed-files</link><pubDate>Wed, 08 Nov 2017 11:57:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6ab60438-2564-41fa-822b-4838dac398dc</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p style="background:white;line-height:18.0pt;margin:0cm 0cm 18.0pt 0cm;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;Hello,&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;I have a bad feeling regarding text styles and its application on Border-Seed-Files.&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;As an example, the following configuration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;- In a DGN.lib I have all my text styles and are available ion every drawings.&lt;br /&gt; - I have created new Border-Seed-Files with these text styles and the used styles are now integrated as a local style in the Border-Seed-File (recognizable by the blue tick in the text style window).&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;So far everything is ok.&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;But now my thoughts and fears ....&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;If somebody later changes and saves one of the used text styles, all texts in this drawing will be adjusted accordingly.&lt;br /&gt; This would lead to texts from the Border being changed unintentionally!?&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;So my question is, does it make sense to work in a Border-Seed-File with text styles or should it be better to put all the texts on text style &amp;quot;none&amp;quot; at the end just before releasing them?&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm 18.0pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;I hope I could explain my fears and would be glad if you could tell me your personal opinions and how you are working on that.&lt;/span&gt;&lt;/p&gt;
&lt;p style="background:white;line-height:18.0pt;margin:18.0pt 0cm .0001pt 0cm;text-align:start;"&gt;&lt;span style="color:black;font-family:&amp;#39;Helvetica&amp;#39;,sans-serif;font-size:11.5pt;"&gt;Many Thanks&lt;br /&gt; Regards&lt;br /&gt; Raphael&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>View independent fill</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/109072/view-independent-fill</link><pubDate>Thu, 05 Oct 2017 09:03:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cc40261d-8281-47f1-9279-fabddf4dd71b</guid><dc:creator>Oto</dc:creator><description>&lt;p&gt;I just noticed that if dropping Truetype text to geometry then filled shapes do not honor view attribute fill setting. This actually is good feature and looking how to manually add such kind of independent fill for other elements. For example cells in cell library preview do not show fill so this would allows to show filled shapes in cell library preview.&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/273/drop_2D00_text_2D00_fill.dgn"&gt;communities.bentley.com/.../drop_2D00_text_2D00_fill.dgn&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Best solution for seed file resolution of new seed files if working in imperial as well in metric .</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/140115/best-solution-for-seed-file-resolution-of-new-seed-files-if-working-in-imperial-as-well-in-metric</link><pubDate>Thu, 24 Aug 2017 08:40:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9e99998e-5ac2-437a-aa66-aec2db1e61b4</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hello&lt;br /&gt;In the context of new seed files that are created, the question arises what is the best way to configure the DGN file resolution if you draw in metric as well in imperial system and want to have the greatest possible compatibility&amp;hellip;&amp;hellip;.&lt;br /&gt;The basic idea is, how can I configure the metric and imperial seed files so I can later reference one to the other / change drawing units from one to the other / copy elements from one to another,&amp;nbsp;&amp;nbsp; with minimal effort?&lt;br /&gt;Therefore, it is necessary to configure the factor &lt;strong&gt;25.4&lt;/strong&gt; as best as possible in the seed files to avoid a tedious calculation of factors during drawing / referencing / copying / changing units etc&amp;hellip;.. in both direction.&lt;br /&gt;Scaling an inch drawing to mm, the scale factor is an exact 1 digit point number &lt;strong&gt;25,4&lt;/strong&gt; what makes scaling in this way easy.&lt;br /&gt;But scaling from mm to inch is more complicate&amp;hellip;.., the scale factor is 1/25=&lt;strong&gt;0,03937007874015748&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;What would be your solution for resolution setting of each seed files?&lt;/p&gt;
&lt;p&gt;Thanks&lt;br /&gt;Greeting&lt;br /&gt;Raphael&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question II</title><link>https://communities.bentley.com/achievements/cd3cd235-25c1-476e-bb88-33a5705ca45a</link><pubDate>Thu, 24 Aug 2017 04:08:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5610a4be-fb59-43ad-8a58-ab1ad1f55fca</guid><dc:creator /><description>Ask 10 questions in a forum.</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Thu, 24 Aug 2017 01:17:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d134a646-242b-4332-b996-d6b922611e1a</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>Cells lose the text style after move - need your help</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/137939/cells-lose-the-text-style-after-move---need-your-help</link><pubDate>Thu, 29 Jun 2017 07:21:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:286d3066-e8a0-40d6-aced-e3edbe63e98d</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hello,&lt;br /&gt;I have a problem and need your help.&lt;br /&gt;Attached is a DGN drawing and a cell library.&lt;br /&gt;In the cell library there are 2 cells, each consisting of a graphic and 2 data fields.&lt;br /&gt;The data fields are formatted with the text style named &amp;quot;consolas in 0.06&amp;quot;.&lt;br /&gt;If I place these cells on my drawing (important after placing the cell do not move them!) and check the text style of the data fields using the Element Selector Tool or the Element Information window, they still have the original text style named &amp;quot;consolas in 0.06&amp;quot;, as well as in the cell library.&lt;/p&gt;
&lt;p&gt;If now I move these cells on my drawing, either with the move command or drag with the mouse, the data fields of the cells lose the text style names !!!&lt;br /&gt;The formatting of the data fields remains as defined in the text style &amp;quot;consolas in 0.06&amp;quot;, but they no longer have the named text style !!&lt;br /&gt;Selection with the Element Selection Tool for this named text style is no longer possible ....!?&lt;/p&gt;
&lt;p&gt;I have tried a lot to find the cause.&lt;br /&gt;The only solution is to delete the existing data fields in the cell library and replace them with new ones. Then it works without problems.&lt;/p&gt;
&lt;p&gt;When comparing the element information between the old data fields and the newly created, I noticed something with the RAW DATALINKAGES.&lt;br /&gt;The old data fields have the value 3, with corresponding 3 binary entries in the extended linkages window. There are 3 binary entries &amp;quot;Type 0x80d4, Words 16&amp;quot;.&lt;br /&gt;The new data fields, however, have the value 1 under RAW DATALINKAGES, with only one entry &amp;quot;Type 0x80d4, Words 16&amp;quot;.&lt;/p&gt;
&lt;p&gt;(I do not know whether this has something to do with the problem, but I would be interested in what this information under RAW DATA mean)&lt;/p&gt;
&lt;p&gt;Unfortunately, I could not find out more :(&lt;/p&gt;
&lt;p&gt;Since I am afraid that this problem could also exist on many other cells in our libraries, I would like to know what is the reason and what is the best way to solve them and avoid this problems for the future.&lt;br /&gt;It would also be important to know how I could check all my libraries, with small workload as possible.&lt;/p&gt;
&lt;p&gt;Thanks a lot&lt;br /&gt;regards&lt;br /&gt;Raphael&lt;/p&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/273/Microstation-problem-_2D00_-lost-text-style.zip"&gt;communities.bentley.com/.../Microstation-problem-_2D00_-lost-text-style.zip&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Some questions about display resolution and a configuration for a new workstation</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/116776/some-questions-about-display-resolution-and-a-configuration-for-a-new-workstation</link><pubDate>Mon, 07 Mar 2016 21:07:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bbdd3a46-fd10-4bee-8ed8-43148ae155dc</guid><dc:creator>Raphael :)</dc:creator><description>&lt;div&gt;Hi,&lt;/div&gt;
&lt;div&gt;Some questions about display resolution and a configuration for a new workstation.&lt;/div&gt;
&lt;div&gt;I&amp;#39;m going to configure a new workstation, consisting of a DELL Workstation &amp;quot;T5810&amp;quot; and 4 Dell UltraSharp displays.&lt;/div&gt;
&lt;div&gt;I mainly work with MicroStation V8i SS3, much in 2D and some 3D graphics.&lt;/div&gt;
&lt;div&gt;Additional to this, I also use EPLAN for electrical schematics, usual Office programs and databases.&lt;/div&gt;
&lt;div&gt;OS is 64bit Windows7.&lt;/div&gt;
&lt;div&gt;I would not risk a bad buy, so I would like to have a few opinions&amp;hellip;..&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;&lt;strong&gt;CONFIGURATION FOR NEW WORKSTATION:&lt;/strong&gt;&lt;/div&gt;
&lt;div&gt;- Processor: Intel Xeon E5-1630 v3 (4 cores, 3.7 GHz, 10 MB)&lt;/div&gt;
&lt;div&gt;- RAM: 32 GB 2133 MHz DDR4 (4x8 GB) RDIMM ECC&lt;/div&gt;
&lt;div&gt;- Graphic Card: AMD FirePro W5100, 4 GB, 4 DP&lt;/div&gt;
&lt;div&gt;- Power Supply 825W&lt;/div&gt;
&lt;div&gt;- Hard disk: SATA 3.5 &amp;quot;500GB 7200&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;Is this configuration ok?&lt;/div&gt;
&lt;div&gt;Enough memory?&lt;/div&gt;
&lt;div&gt;Graphics card recommended? Enough memory and enough power for my 4 monitors in a suitable resolution?&lt;/div&gt;
&lt;div&gt;Would maybe the installation of a SSD hard drive be recommended?&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;&lt;strong&gt;DISPLAYS:&lt;/strong&gt;&lt;/div&gt;
&lt;div&gt;Currently I am working on following displays:&lt;/div&gt;
&lt;div&gt;2x DELL U2311H, 23 &amp;quot;, 16: 9, pixel pitch of 0,265mm, resolution 1920x1080 at 60 Hz,&lt;/div&gt;
&lt;div&gt;1x DELL 2007FP, 20 &amp;quot;, 4: 3, pixel pitch of 0.255mm, resolution 1600x1200 at 60 Hz,&lt;br /&gt;&lt;br /&gt;The 23 &amp;quot; 16: 9 has not made me really happy because of the lack of height compared to my old 21&amp;quot; 4: 3 displays.&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;Therefore actually I only want to buy 16:10 displays&amp;hellip;&amp;hellip;.&lt;/div&gt;
&lt;div&gt;Since with increasing size this problem seems to disappear and I also have found interesting 16:9 devices, I am not sure what the best is&lt;br /&gt;and need your experience and decision support.&lt;/div&gt;
&lt;div&gt;I am also very uncertain about the display resolution. What is good or perhaps a no-go ...?&lt;/div&gt;
&lt;div&gt;Maximum working distance to the screens is approximately 90cm!&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;&lt;strong&gt;MY SELECTION FOR NEW DISPLAYS:&lt;/strong&gt;&lt;/div&gt;
&lt;div&gt;DELL U2415, IPS panel, 24 &amp;quot;, 16:10, pixel pitch of 0.27mm, resolution 1920x1200 at 60 Hz&lt;/div&gt;
&lt;div&gt;DELL U2515H, IPS panel, 25 &amp;quot;, 16: 9, pixel pitch of 0.216mm, resolution 2560x1440 at 60 Hz&lt;/div&gt;
&lt;div&gt;DELL U2717D, ​​IPS panel, 27 &amp;quot;, 16: 9, pixel pitch of 0.2331mm, resolution 2560x1440 at 60 Hz&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;Since 27&amp;rdquo; perhaps could be a little too much, or is this just a matter of habit ... :)), I actually like 25&amp;quot; quite well. Unfortunately, this is again a 16: 9 format!&lt;/div&gt;
&lt;div&gt;&lt;strong&gt;&lt;em&gt;Unusually for the &lt;span style="text-decoration:underline;"&gt;25&amp;quot;&lt;/span&gt; is the high resolution of &lt;span style="text-decoration:underline;"&gt;2560x1440&lt;/span&gt;, which usually found only on 27&amp;quot; displays!!&lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div&gt;How does this relate in Microstation?&lt;/div&gt;
&lt;div&gt;Is this high resolution rather better for displaying and working on the screen?&lt;/div&gt;
&lt;div&gt;How does Microstation run on a 25&amp;rdquo; display with that higher resolution?&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;&lt;strong&gt;In summary:&lt;/strong&gt;&lt;/div&gt;
&lt;div&gt;- What screen size, by using 4 displays and 90cm working distance, would be good / the best ? 24 &amp;quot;, 25&amp;quot;, 27 &amp;quot;...?&lt;/div&gt;
&lt;div&gt;- What format should be the best for CAD, 16:9 or 16:10, or depending on the display size ...?&lt;/div&gt;
&lt;div&gt;- What is the best resolution, what is advantageous and what an absolute no-go?&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;Thanks for reading to the end .... :)) &amp;nbsp;and for any help.&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;On the picture attached an overview of the different sizes and formats, with my current 23&amp;rdquo; 16:9 display shown in red.&lt;/div&gt;
&lt;div&gt;&amp;nbsp;&lt;/div&gt;
&lt;div&gt;Regards&lt;/div&gt;
&lt;div&gt;Raphael&lt;/div&gt;
&lt;div&gt;&lt;/div&gt;
&lt;div&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/273/MonitorFormate.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-discussions-components-files/273/MonitorFormate.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Strange problem when filling in data fields ???</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/101979/strange-problem-when-filling-in-data-fields</link><pubDate>Mon, 20 Oct 2014 13:43:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1b6e8c95-7727-497d-b25d-ca5f21b96e23</guid><dc:creator>Raphael :)</dc:creator><description>&lt;div id="gt-res-content" class="almost_half_cell"&gt;
&lt;div dir="ltr"&gt;Hello &lt;br /&gt;I am facing a strange problem when filling in data fields, please see attached video. &lt;br /&gt;I create an array that consists of several data fields separated by a dash.&amp;nbsp;&lt;br /&gt;I can handle all data fields and fill in the data fields with the copy data field tool, except the last data field in the array. &lt;br /&gt;If I add a additional data field to this array the problem &amp;quot;shifts&amp;quot; to the last data field an so forth..... if adding another data field!&lt;br /&gt;If at the end of the line, after the last data field, I add a character like a dash everything works perfectly.&lt;/div&gt;
&lt;div dir="ltr"&gt;&lt;/div&gt;
&lt;div dir="ltr"&gt;Gridlock and Snaplocks are off. &lt;br /&gt;&lt;br /&gt;What happens here .....?&lt;/div&gt;
&lt;div dir="ltr"&gt;&lt;/div&gt;
&lt;div dir="ltr"&gt;I need urgently help for this issue.&lt;/div&gt;
&lt;div dir="ltr"&gt;&lt;/div&gt;
&lt;div dir="ltr"&gt;many thanks&lt;/div&gt;
&lt;div dir="ltr"&gt;Regard&lt;/div&gt;
&lt;div dir="ltr"&gt;Raphael&lt;/div&gt;
&lt;div dir="ltr"&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/273/Datafields.zip"&gt;communities.bentley.com/.../Datafields.zip&lt;/a&gt;&lt;/div&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Place Cell relative issue - wrong levels be applied</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/101098/place-cell-relative-issue---wrong-levels-be-applied</link><pubDate>Fri, 19 Sep 2014 12:05:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:33b63988-4fe6-41fb-b3f7-97f0fd33e2c5</guid><dc:creator>Raphael :)</dc:creator><description>&lt;p&gt;Hello.&lt;/p&gt;
&lt;p&gt;I have a issue by placing a cell relative.&lt;/p&gt;
&lt;p&gt;The cell was created with the level 1, 2 &amp;amp; 3.&lt;/p&gt;
&lt;p&gt;If I place it relative and the active level for ex. is 10, normaly the cell will be placed with the levels 10, 11 &amp;amp; 12.&lt;/p&gt;
&lt;p&gt;But this will not work.&lt;/p&gt;
&lt;p&gt;Level 1 will be placed as level 8, level 2 as level 9 and level 3 as level 3&lt;/p&gt;
&lt;p&gt;I use V8i SS3 8.11.9.459 and have following additional informations:&lt;/p&gt;
&lt;p&gt;- The cell&amp;nbsp;is&amp;nbsp;a &amp;quot;bigger&amp;quot; cell with&amp;nbsp;more then 1000 elements.&lt;/p&gt;
&lt;p&gt;- Creating a little test cell with 3 circles on different level and placing them relativ will work correctly.&lt;/p&gt;
&lt;p&gt;- After creating a new cell library and creating a new cell from this &amp;quot;bigger&amp;quot; graphic,&amp;nbsp;placing it relativ will also working good.&lt;/p&gt;
&lt;p&gt;What is the reason&amp;nbsp;for this issue?&lt;/p&gt;
&lt;p&gt;It seems the problem will be the cell library....!?&lt;/p&gt;
&lt;p&gt;Because I have a lot of cells, I hope I did not to have to create a new cell library with all this stuf....&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Thanks a lot&lt;/p&gt;
&lt;p&gt;Regards&lt;/p&gt;
&lt;p&gt;Raphael&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>