<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>K Pani's Activities</title><link>https://communities.bentley.com/members/8d75d82e_2d00_f7e6_2d00_4dcc_2d00_a1e8_2d00_f30012c525f7</link><description>K Pani's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Roof Wind Load</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/96603/roof-wind-load</link><pubDate>Thu, 24 Apr 2014 20:29:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d9f7f1e6-9a32-4cc7-b8c6-4ee81a7d8471</guid><dc:creator>K Pani</dc:creator><description>&lt;p&gt;I&amp;#39;m analyzing a shelter made of steel tubes/pipes, that possibly will be covered by some kind of fabric all around. The structure has been modeled as a skeleton of steel tubes and is defined as enclosed for wind load calculation. While using the wind load generation feature in STAAD, I see that the load is being applied on the windward side, but i don&amp;#39;t see corresponding loads (under the same load case) on the leeward side or on the roof, i.e., wind forces acting away from the roof or away from the leeward wall, based on the different &amp;#39;zones&amp;#39; defined in ASCE 7-10. Am I missing an option/toggle in STAAD that would calculate these loads?&lt;/p&gt;
&lt;p&gt;Thanks.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Double Truck in Conspan</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/97142/double-truck-in-conspan</link><pubDate>Thu, 15 May 2014 00:42:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:70fefe8f-c3bb-4c0d-8341-581a5e1a4d04</guid><dc:creator>K Pani</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I&amp;#39;m wondering if CONSPAN considers 90% the truck load when running double truck as per AASHTO LRFD 3.6.1.3 for negative moments or does it take the full truck loads?&lt;/p&gt;
&lt;p&gt;AASHTO 3.6.1.3:&lt;/p&gt;
&lt;p&gt;&amp;quot;For negative moment between points of contraflexure&lt;br /&gt;under a uniform load on all spans, and reaction at&lt;br /&gt;interior piers only, 90 percent of the effect of two design&lt;br /&gt;trucks spaced a minimum of 50.0 ft between the lead&lt;br /&gt;axle of one truck and the rear axle of the other truck,&lt;br /&gt;combined with 90 percent of the effect of the design&lt;br /&gt;lane load.&amp;quot;&lt;/p&gt;
&lt;p&gt;Thanks.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>