<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Ajay Datta's Communities Activities</title><link>https://communities.bentley.com/members/92b21080_2d00_9376_2d00_4efc_2d00_bec9_2d00_a069ec633568</link><description>Recent activity for people in Ajay Datta's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Response modification factor, over strength factor and deflection amplification factor</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/178320/response-modification-factor-over-strength-factor-and-deflection-amplification-factor</link><pubDate>Wed, 17 Apr 2019 07:31:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4425df45-c9d4-40e7-8b97-f355cea43b78</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;&lt;span&gt;&lt;strong&gt;In this connection I have seen the following reply&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;div style="padding-left:30px;"&gt;Seth Guthrie&amp;nbsp;&lt;a href="/products/ram-staad/f/ram-staad-forum/168999/ram-frame---over-strength-factor-omega-and-deflection-amplification-factor-cd/484929#484929"&gt;6 months ago&amp;nbsp;&lt;/a&gt;in reply&lt;/div&gt;
&lt;div style="padding-left:30px;"&gt;
&lt;div style="padding-left:30px;"&gt;
&lt;p style="padding-left:30px;"&gt;Yes, You can manually enter a combination with some extra factor like Cd to get amplified values, but I honestly find it faster to just factor the deflection results manually or factor the limit instead.&amp;nbsp;&lt;/p&gt;
&lt;/div&gt;
&lt;/div&gt;
&lt;p&gt;I have some confusion and request clarification&amp;nbsp; regarding use of Response modification factor (R) , Overstrength factor(Ω₀) and Deflection amplification factor (Cd)&lt;/p&gt;
&lt;p&gt;In Staad GUI input for seismic load definition I get the opportunity to give Response modification factor Rx and Rz .&lt;/p&gt;
&lt;p&gt;While preparing load combination for Strength design I get the opportunity to use over strength factor (Ω₀) as shown below&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Next about Cd two questions?&lt;/p&gt;
&lt;p&gt;I suppose this deflection amplification factor(Cd) is to be used in in conjunction with Serviceability&amp;nbsp;design? Is this required required to be considered for strength design as well?&lt;/p&gt;
&lt;p&gt;How to use this Cd as in the seismic definition input as there was no scope to input.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;Basic Combination for Strength design with seismic load (ASCE-7-2005)&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;(1.2+0.2Sds) D+Ω₀Qe+L+0.2S&lt;/li&gt;
&lt;li&gt;(0.9-.2Sds) D+ Ω₀Qe+1.6H&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Hope someone will clarify&lt;/p&gt;
&lt;div class="content full threaded-reply-content user-defined-markup"&gt;
&lt;div class="content"&gt;&lt;/div&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>WARNING SELF WEIGHT ... MORE THAN TOTAL WEIGHT</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/177409/warning-self-weight-more-than-total-weight</link><pubDate>Sat, 30 Mar 2019 13:19:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:329a19c7-c945-4f84-a63c-dd2cebd56714</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;I get the following warning in my analysis. Staad file attached&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/RVISED-BY-AJAY_2D00_-2FRAME.std"&gt;communities.bentley.com/.../RVISED-BY-AJAY_2D00_-2FRAME.std&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp; *WARNING- APPLIED SELFWEIGHT IS MORE THAN TOTAL WEIGHT OF ALL&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; STRUCTURAL ELEMENTS IN LOAD CASE&amp;nbsp;&amp;nbsp;&amp;nbsp; 105 ALONG Y.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; THIS COULD BE DUE TO SELFWEIGHT APPLIED TO SPECIFIC&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; LIST OF MEMBERS/PLATES/SOLIDS/SURFACES.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; TOTAL UNFACTORED WEIGHT OF THE STRUCTURE =&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 822.911 KN&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED =&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 1645.822 KN&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Reference load-Seismic-definition-Seeismic-load</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/177590/reference-load-seismic-definition-seeismic-load</link><pubDate>Wed, 03 Apr 2019 08:15:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cb8ec196-5e75-42bb-b118-c369fcc791ca</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;meta content="text/html; charset=us-ascii" /&gt;
&lt;meta name="Generator" content="Microsoft Word 15 (filtered medium)" /&gt;
&lt;!--[if gte mso 9]&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 9]&gt;&lt;![endif]--&gt;


&lt;div class="WordSection1"&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;Dear Sir;&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;I already posted in forum but my problem did not get resolved.&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;1.First I have used Reference loads
&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;2.Then created seismic definition using reference load&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;3. Then generated automatically seismic load using seismic definition.&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;4. Now I want to combine different loads with seismic load for direct analysis.&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;But get some error which means &amp;nbsp;&amp;#8220;cannot combine reference load with primary loads&amp;#8221;&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;How do I combine seismic load with other loads in such situation. Please advise&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;Thanks&lt;/span&gt;&lt;/div&gt;
&lt;div class=""&gt;&lt;span style="font-size:18.0pt;"&gt;Ajay&lt;/span&gt;&lt;/div&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Deflection Amplification Factor Cd</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/183152/deflection-amplification-factor-cd</link><pubDate>Sat, 27 Jul 2019 11:25:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:98e5c776-b65c-4a98-b465-4a400cc3950a</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;As per ASCE 7 deflection amplification factor Cd=3 to be use for my structure which is cantilever car park.&lt;/p&gt;
&lt;p&gt;My question is do I have to multiply both vertical as well horizontal deflection due to seismic load by Cd value&amp;nbsp; to check the serviceabilty condition.of vertical deflection of span/180 at the cantilever end?&lt;/p&gt;
&lt;p&gt;Or this amplification factor is to be applied for the horizontal deflection(DRIFT)?&lt;/p&gt;
&lt;p&gt;Please can someone clarify?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>line too long error message</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/181594/line-too-long-error-message</link><pubDate>Tue, 25 Jun 2019 07:03:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9ea41852-59bd-4bfa-b906-7ca2798edaa3</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;I have a large load combinations which takes more than one hour in my computer system. Unfortunately after one hour I get a error message &amp;quot;one or more lines too long-try to split into two lines&amp;quot;&lt;/p&gt;
&lt;p&gt;Can we not get this simple editor check message within few seconds of the run so that we can correct the same without wasting our time. Please advise&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Post processing Results setup</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/182000/post-processing-results-setup</link><pubDate>Wed, 03 Jul 2019 11:33:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dcc01d21-843c-4ced-9706-775ed65745f3</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;I am trying to use the Results Setup for checking the Utilisation Ratio of various GROUP of&amp;nbsp; members for optimisation. However only once I get to see the Result setup window after I click Postprocessing.&lt;/p&gt;
&lt;p&gt;Second time this window does not appear . Can you help me so that I can repeatedly see the Result Setup window in the same postprocessing.&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/post-processing-screenshot.jpg" /&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/REVISED-MODEL-SIX-FRAMES-6M-BAY-SERVICEABILTY-_28002B00_X-NOTIONAL-LOAD_2900_--2M-PORTAL-DEPTH-12-JUNE.std"&gt;communities.bentley.com/.../REVISED-MODEL-SIX-FRAMES-6M-BAY-SERVICEABILTY-_28002B00_X-NOTIONAL-LOAD_2900_--2M-PORTAL-DEPTH-12-JUNE.std&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>NUMBER OF LOADS IN A LOAD ENVELOPE</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/180704/number-of-loads-in-a-load-envelope</link><pubDate>Fri, 07 Jun 2019 06:18:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bf76b13e-e0c9-4f84-8321-bc8d46909761</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;I HAVE A PROBLEM WHERE THE NUMBER OF REPEATED LOADS ARE MORE THAN 600&amp;nbsp;&lt;/p&gt;
&lt;p&gt;WHEN RUN STRENGTH ANALYSIS I GET THE ERROR AT THE END &amp;quot;LOADS MORE THAN 555 NOT ALLOWED IN LOAD ENVELOPE&amp;quot;&lt;/p&gt;
&lt;p&gt;SO I PUT LOAD LIST 2001 TO 2688 AND RUN FOR STRENGTH ANALYSIS&lt;/p&gt;
&lt;p&gt;BUT WHEN I HAVE TO RUN FOR SERVICEABILTY&amp;nbsp; WITHOUT &lt;span style="text-decoration:underline;"&gt;&lt;em&gt;&lt;strong&gt;LOAD ENVELOPE IT WILL NOT CHECK FOR DFF&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt; IS THAT CORRECT? SO WHAT I WILL HAVE DO.&lt;/p&gt;
&lt;p&gt;PLEASE ADVISE&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>large load combination</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/179448/large-load-combination</link><pubDate>Mon, 13 May 2019 03:46:36 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:fde7bbab-87f3-4c77-bd66-d14a0cb29200</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/Copy-of-Attachment-2B_5F00_DUQM_5F00_SHELTER-LC_5F00_STRENGTH_5F00_REV_2D00_O1-_2D00_29_2D00_4_2D00_2019.xls"&gt;communities.bentley.com/.../Copy-of-Attachment-2B_5F00_DUQM_5F00_SHELTER-LC_5F00_STRENGTH_5F00_REV_2D00_O1-_2D00_29_2D00_4_2D00_2019.xls&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;I am sorry this is not a staad analysis problem but excel macro. I have generated large load combinations using excel. However I am unable to INSERT the text REPEAT LOAD after each LOAD&amp;nbsp; XXXX line AS SHOWN BELOW. I am sure someone can help me with a proper VB macro or any other way.&lt;/p&gt;
&lt;p&gt;*2001 1.4 Ds + 1.4 DF + 1.4 DOT + 1.4 DOP + 1.4 FFT + 1.4 FFL + 1.4 AFT&lt;/p&gt;
&lt;p&gt;* + 1.4 AFL + 1.4 CRD- 1/1&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;LOAD&amp;nbsp; 2001&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffff00;color:#3366ff;"&gt;REPEAT LOAD&lt;/span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;5 1.4 6 1.4 7 1.4 9 1.4 18 1.4 19 1.4 20 1.4 21 1.4 27 1.4&lt;/p&gt;
&lt;p&gt;*2002 1.4 Ds + 1.4 DF + 1.4 DOT + 1.4 DOP + 1.4 FFT + 1.4 FFL + 1.4 AFT&lt;/p&gt;
&lt;p&gt;* + 1.4 AFL + 1.4 CRD- 1/2&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;LOAD&amp;nbsp; 2002&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffff00;color:#0000ff;"&gt;REPEAT LOAD&lt;/span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;5 1.4 6 1.4 7 1.4 9 1.4 18 1.4 19 1.4 20 1.4 21 1.4 28 1.4&lt;/p&gt;
&lt;p&gt;*2003 1.4 Ds + 1.4 DF + 1.4 DOT + 1.4 DOP + 1.4 FFT + 1.4 FFL + 1.4 AFT&lt;/p&gt;
&lt;p&gt;* + 1.4 AFL + 1.4 CRD- 2/1&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;LOAD&amp;nbsp; 2003&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffff00;color:#0000ff;"&gt;REPEAT LOAD&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;5 1.4 6 1.4 7 1.4 9 1.4 18 1.4 19 1.4 20 1.4 21 1.4 29 1.4&lt;/p&gt;
&lt;p&gt;*2004 1.4 Ds + 1.4 DF + 1.4 DOT + 1.4 DOP + 1.4 FFT + 1.4 FFL + 1.4 AFT&lt;/p&gt;
&lt;p&gt;* + 1.4 AFL + 1.4 CRD- 2/2&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;LOAD&amp;nbsp; 2004&lt;/p&gt;
&lt;p&gt;&lt;span style="background-color:#ffff00;color:#0000ff;"&gt;REPEAT LOAD&amp;nbsp;&amp;nbsp;&lt;/span&gt;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/p&gt;
&lt;p&gt;5 1.4 6 1.4 7 1.4 9 1.4 18 1.4 19 1.4 20 1.4 21 1.4 30 1.4&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>INSTABILITY WARNING</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/180083/instability-warning</link><pubDate>Sat, 25 May 2019 06:08:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7fcefda6-2147-416f-8297-56de06974001</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;HELLO I AM UNABLE TO FIND THE REASON FOR INSTABILITY WARNING. CAN ANY ONE HELP?&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL-_2B00_Z-_2D00_Z_2900_--8-FRAMES-member-tension-PDELTA_2800_PIPE_2900_INSTABILTY.std"&gt;communities.bentley.com/.../CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL-_2B00_Z-_2D00_Z_2900_--8-FRAMES-member-tension-PDELTA_2800_PIPE_2900_INSTABILTY.std&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ram connection report in metric unit</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/179902/ram-connection-report-in-metric-unit</link><pubDate>Wed, 22 May 2019 03:57:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7f3c9990-7028-4615-aaec-ee10c272f5df</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;Hello I have run the staad file with metric(MKS) unit configuration in connect edition. But the Ram connection report is produced in FPS system.&lt;/p&gt;
&lt;p&gt;Can you advise how to resolve this matter&amp;nbsp;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_--8-FRAMES-member-tension-PDELTA_2800_PIPE_2900_.std"&gt;communities.bentley.com/.../CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_--8-FRAMES-member-tension-PDELTA_2800_PIPE_2900_.std&lt;/a&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_--8-FRAMES-member-tension-PDELTA_2800_PIPE_29005F00_Report.doc"&gt;communities.bentley.com/.../CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_--8-FRAMES-member-tension-PDELTA_2800_PIPE_29005F00_Report.doc&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>serviceability load combination with seimic load</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/179471/serviceability-load-combination-with-seimic-load</link><pubDate>Mon, 13 May 2019 11:48:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c4b7c1c2-f947-45b2-b203-386e16382f58</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;Sorry my earlier question on this subject was wrong&lt;/p&gt;
&lt;p&gt;The term should be&amp;nbsp;&lt;strong&gt;System Overstrength Factor OMEGA&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;The correct question is&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;WE ARE SUPPOSED TO CONSIDER &lt;strong&gt;System Overstrength Factor OMEGA=3&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;FOR&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;span&gt;STRENGTH&amp;nbsp;DESIGN&lt;/span&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;A TYPICAL LOAD COMBINATION&amp;nbsp;&lt;span&gt;AS GIVEN BELOW&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;**EMPTY WEIGHT +THERMAL +SEISMIC&lt;br /&gt;**X DIR&lt;br /&gt;&lt;span&gt;LOAD 105 : DEAD (0.6-.2X.152) +SS +TEMP +3&amp;nbsp;X 0.7SEIS(+X) +NOTIONAL X&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;br /&gt;&lt;span&gt;REPEAT LOAD&lt;/span&gt;&lt;br /&gt;&lt;span&gt;1 0.5696 41 0.6 42 0.6 2000 2.1 14 2.1 3001 0.6 3007 0.7&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;**Z DIR&lt;br /&gt;LOAD 107 : DEAD (0.6-.2X.152) +SS +TEMP +3&amp;nbsp;X 0.7SEIS(+Z) +NOTIONAL X&lt;br /&gt;REPEAT LOAD&lt;br /&gt;1 0.5696 41 0.6 42 0.6 2001 2.1 14 2.1 3001 0.6 3007 0.7&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;MY QUESTION IS DO I HAVE TO CONSIDER &lt;strong&gt;System Overstrength Factor OMEGA&lt;/strong&gt;&amp;nbsp;IN THE SERVICEABILTY LOAD COMBINATION TOO?&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>PRETENSION IN TIE ROD FOR CANTILEVER ROOF STRUCTURE</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/179256/pretension-in-tie-rod-for-cantilever-roof-structure</link><pubDate>Wed, 08 May 2019 07:48:38 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1c4be2af-d3f6-4c47-858a-2c1264021ee0</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;IN MY PROBLEM I GET A DOWNWARD VERTICAL DEFLECTION OF 92MM WHICH IS MORE THAN ALLOWABLE(SPAN/90=72MM). I WANT TO APPLY PRETENSION IN THE TIE ROD TO REDUCE THIS DEFLECTION. HOW TO HANDLE THIS PROBLEM CAN ANYONE ADVICE? IS IT BY TRIAL AND ERROR METHOD.&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_--8-FRAMES-member-truss-direct-analysis_2800_UB_2900_-SERVICABILTY.std"&gt;communities.bentley.com/.../CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_--8-FRAMES-member-truss-direct-analysis_2800_UB_2900_-SERVICABILTY.std&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>ERROR IN USER TABLE</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/179180/error-in-user-table</link><pubDate>Tue, 07 May 2019 08:49:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:177ebecf-0763-4960-9e27-5f2fef5ae1d5</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;I WANT TO USE 50MM SOLID ROD AS TIE MEMBER TO CARRY ONLY TENSION FOR WHICH I CREATED THE FOLLOWING USER TABLE&lt;/p&gt;
&lt;p&gt;WHAT IS WRONG? I GET THE ERROR?&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;START USER TABLE&lt;/p&gt;
&lt;p&gt;TABLE 1&lt;/p&gt;
&lt;p&gt;UNIT MM KN&lt;/p&gt;
&lt;p&gt;PIPE&lt;/p&gt;
&lt;p&gt;PIP50&lt;/p&gt;
&lt;p&gt;50 0.05&lt;/p&gt;
&lt;p&gt;END&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp; **ERROR READING THE ABOVE USER TABLE #&amp;nbsp; 1&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; section-name:&amp;nbsp; PIP50&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; CHECK THE NUMBER OR VALUES OF PARAMETERS ENTERED.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Direct analysis with tension member</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/179120/direct-analysis-with-tension-member</link><pubDate>Mon, 06 May 2019 08:04:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:909e9385-33f7-40ad-b540-f17efe0c72c0</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;In my analysis program I am getting error and unable to find the reason. Can anyone help me?&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_-single-frame-_2D00_-8-FRAMES.std"&gt;communities.bentley.com/.../CAR-PARK-Frame-_28002B002D00_TEMP-_2B00_X-_2D00_X-NOTIONAL_2900_-single-frame-_2D00_-8-FRAMES.std&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>LIMCON in conjunction with STAAD PRO</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/178848/limcon-in-conjunction-with-staad-pro</link><pubDate>Mon, 29 Apr 2019 11:38:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:64b7686c-c3f7-4630-bf33-64b5fe3d2e57</guid><dc:creator>Ajay Datta</dc:creator><description>&lt;p&gt;Hello I use RAM connection program in conjunction with Staad Pro analysis program where in for any connection design the forces in a member/joint is directly available from Staad.&lt;/p&gt;
&lt;p&gt;However I never used LIMCON. Can I use LIMCON in conjunction with Staad pro Analysis to get the forces for connection design? Can anybody give few steps to start with my practice?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>