<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>jeroen.decooman's Communities Activities</title><link>https://communities.bentley.com/members/98df027b_2d00_11d7_2d00_47bc_2d00_8540_2d00_a8911417c604</link><description>Recent activity for people in jeroen.decooman's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Problem exchanging IFC files with Revit</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/243600/problem-exchanging-ifc-files-with-revit</link><pubDate>Thu, 30 Mar 2023 13:48:36 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d5af9b3-879a-46b1-9270-d127449712fb</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;I was wondering if there are any people who work with both Openbuildings and Revit who could help me with a problem.&lt;/p&gt;
&lt;p&gt;We are working with contractors who work with Revit, and we would like to exchange files through IFC. However, when they open our IFC&amp;#39;s they see all our cutouts/subtractions/other operations in addition to the model, so the model is not usable for them. When they convert the IFC to a Revit file, the cutouts/substractions/other operations are no longer visible, and they can work with the model, but sometimes elements seem to disappear (which are still present in the IFC). I export with the IFC2x3 CV2.0 setting.&lt;/p&gt;
&lt;p&gt;Short recap:&lt;br /&gt;-Export dgn through Openbuildings as IFC&lt;br /&gt;-Import IFC directly in Revit: additional elements which makes the model unusable&lt;br /&gt;-Convert IFC to rvt and import in Revit: additional elements disappear, but sometimes other elements disappear as wel.&lt;/p&gt;
&lt;p&gt;I am using the latest version of Openbuildings (10.10.00.199)&lt;/p&gt;
&lt;p&gt;Is there maybe someone who has had the same problem?&lt;/p&gt;
&lt;p&gt;With kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen De Cooman&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;With kind regards,&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Discussion Starter I</title><link>https://communities.bentley.com/achievements/21025ab1-febb-4fb4-a872-d32a921cb45c</link><pubDate>Wed, 05 Apr 2023 09:09:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e10db8be-4a18-4186-a9a3-afcbfa3b4933</guid><dc:creator /><description>Start a discussion in a forum that receives 5 replies.</description></item><item><title>section clip placement</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/243415/section-clip-placement</link><pubDate>Mon, 27 Mar 2023 12:23:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:373837f6-4fe2-4827-b6f1-65cacb6df79e</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;Hello, I was wondering what determines the elevation level when placing a &amp;#39;section clip&amp;#39;. I am using &amp;#39;Clip volume: clip volume&amp;#39; &amp;gt; &amp;#39;section clip tools&amp;#39; &amp;gt; &amp;#39;apply clip by section plane&amp;#39;, but when I place it this way, it seems to randomly jump up or down over long distances. My &amp;#39;acs plane snap&amp;#39; is turned off, and I have also reset my ACS. See below for an example. Here it placed it around 6000 meters above the place I clicked.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5917/pastedimage1679919756796v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;I am using Openbuildings Designer 10.10.00.199&lt;/p&gt;
&lt;p&gt;With kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen De Cooman&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Reference placing in wrong size</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/234499/reference-placing-in-wrong-size</link><pubDate>Wed, 24 Aug 2022 12:22:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8c4ae44e-2a87-4b8c-8bf2-d02f361f63b5</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;We have a file where all references seem to be placed according to a scale (1:2), but we can&amp;#39;t find where this setting is:&lt;br /&gt;-Reference scale is 1:1&lt;br /&gt;-Model Annotation scale is 1:1&lt;br /&gt;-When we measure lengths are 1/2 the length from the original files.&lt;br /&gt;-When we dimension them with linear dimensions they give the correct distance.&lt;br /&gt;-Working units are the same&lt;br /&gt;Is there another place where you can change scales?&lt;/p&gt;
&lt;p&gt;With kind regards and thanks in advance,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Problem with flip handle on cell door</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/234493/problem-with-flip-handle-on-cell-door</link><pubDate>Wed, 24 Aug 2022 09:45:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b866202e-9c7c-437b-a582-b07836d98927</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;I am trying to make a door element for a revoling door, with a regular cell as the underlying 3d part. When I try to place it, the flip handle is so far away from the element that I get a &amp;quot;Solids Working Area Information&amp;quot; warning every time I open the file. It also makes the file a lot slower. The cell itself doesn&amp;#39;t seem to be the problem, because when I drop the application element to a regular cell all the warnings and slowness stops.&lt;br /&gt;On what is the distance of the flip handle to the door based? Can I change this?&lt;/p&gt;
&lt;p&gt;I am using OBD 10.09.02.36.&lt;/p&gt;
&lt;p&gt;With kind regards, and thanks in advance.&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Structural settings menu not opening</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/234359/structural-settings-menu-not-opening</link><pubDate>Mon, 22 Aug 2022 10:26:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:37c6daca-c478-4830-9e3d-514cbd48f247</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;When I try to open the structural settings menu, it fails to do so. It doesn&amp;#39;t matter if I try to do so from the search prompt, or from file&amp;gt;settings&amp;gt;building&amp;gt;structural settings. It does not crash, it does not give an error, or any kind of message, in the message center, it just does nothing.&lt;br /&gt;I need access to these settings to turn off the irritating markers in railings, which popped up again after a crash. Unless somebody knows of another way to turn these off?&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1661163837590v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;I am using Openbuildingsdesigner version 10.09.02.36&lt;br /&gt;It hasn&amp;#39;t been always like this, although I couldn&amp;#39;t tell you when it started. It doesn&amp;#39;t seem to happen with my colleagues, who should be using the (more or less) same settings. It als happens in all files. It doesn&amp;#39;t seem to affect other setting windows.&lt;/p&gt;
&lt;p&gt;With kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Problem printing with raster images in smooth display style</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/231032/problem-printing-with-raster-images-in-smooth-display-style</link><pubDate>Thu, 09 Jun 2022 09:31:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:fe8f0c27-6980-4659-9a1e-8648a13263e1</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I was wondering if anybody has had the same problem, and hopefully a solution.&lt;/p&gt;
&lt;p&gt;I am trying to print to jpg from a 3d model, and have attached a raster image. If I print in smooth display style without shadows everything is fine. However, when I switch to smooth display style with shadows&amp;nbsp; it won&amp;#39;t print the raster image anymore. (although it still shows up in the view.) Since it prints correctly without shadows, I don&amp;#39;t think this is a level setting problem (I checked too) or a printer settings problem. Anybody any suggestion of things to try? See images below for images.&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1654766722738v1.png" alt=" " /&gt;&lt;br /&gt;smooth display style with shadows in view&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1654766942522v2.png" alt=" " /&gt;&lt;br /&gt;smooth no shadows print jpg&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1654767013914v3.png" alt=" " /&gt;&lt;br /&gt;smooth with shadows print jpg&lt;/p&gt;
&lt;p&gt;with kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen De Cooman&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Adjusting solids without making parametric solids</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/218342/adjusting-solids-without-making-parametric-solids</link><pubDate>Thu, 19 Aug 2021 08:45:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f31776a1-7547-4486-9be8-33727ff917f0</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;I was wondering if it was possible to model and adjust solids in Openbuildings without making a parametric solid that keeps every step saved. I have colleagues that tend to design in Openbuildings, but keeps adjusting certain volumes, cutting here and there, pushing and pulling a bit, cutting holes, and after a while we get parametric solids with a tree of around 50 steps if not more. We get the feeling that this might make for a very heavy object, and indeed files seem to be getting rather large rather quick. We can always drop the object, but it would be easier if we had access to either non feature tools, or to a setting to automaticly drop an object after using a tool.&lt;/p&gt;
&lt;p&gt;Thanks in advance and with kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Access IFC data for a clash control</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/219192/access-ifc-data-for-a-clash-control</link><pubDate>Wed, 08 Sep 2021 07:45:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:15f22b22-e07d-4c56-9733-44c94f6083eb</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;We received an IFC model from an engineering firm and would like to do a clash control. The problem is that a lot of the pipework is being cast in to the concrete, and so currently running the clash detection gives about 2000 clashes. They have connected IFC information to the model to clarify if it&amp;#39;s being cast in or not, but I don&amp;#39;t know how to access it in Openbuildings.&lt;br /&gt;This is how it looks in Solibri:&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1631086867644v1.png" alt=" " /&gt;&lt;br /&gt;&lt;br /&gt;Is there any way to just reference the IFC file, use the &amp;quot;suppress clashes with elements that have a specific property value&amp;quot;, to prevent this? Or are there any other suggestions on how to approach this.&lt;br /&gt;Of course I know the easiest answer is to ask the firm to supply the files with either the elements on separate layers or even a separate file, but if possible I would like to do it ourselves to prevent any additional charges.&lt;/p&gt;
&lt;p&gt;Thanks,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to turn off position markers on railing?</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/219600/how-to-turn-off-position-markers-on-railing</link><pubDate>Thu, 16 Sep 2021 15:24:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4eeba361-fe3c-4da6-8133-926961bb69ef</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;When placing railings, my Openbuildings also places all these position markers (seen in blue en green):&lt;br /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1631805912442v1.png" alt=" " /&gt;&lt;br /&gt;I&amp;#39;m pretty sure there must be an easy way to turn these off, but I can&amp;#39;t seem to find it? Anybody who can help me with this?&lt;/p&gt;
&lt;p&gt;Thank you very much,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can you remove the fill of a wall in a section/wall</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/219480/can-you-remove-the-fill-of-a-wall-in-a-section-wall</link><pubDate>Tue, 14 Sep 2021 14:42:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:fef136e1-f26d-42ac-8b4d-b3da7cfef787</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I was curious if anybody knew of a way to make walls without fills in plans that are generated from 3d models. If you look at the example below, I have some walls which will be demolished, and I would like to keep the outlines visible. However, if you look at the image below, you see that the sinks (which are compound cells) are getting hidden. This in spite that the plane of the underside is under the compound cell.&lt;br /&gt;Does anybody know any tricks to get this done? I hope I am just verlooking some settings.&lt;/p&gt;
&lt;p&gt;&lt;img height="242" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1631630169056v1.png" width="505" alt=" " /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1631630389358v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Thanks in advance,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Railing not extending to the end</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/219532/railing-not-extending-to-the-end</link><pubDate>Wed, 15 Sep 2021 15:29:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4d54c8c5-9bbd-47f2-964b-c3cea10b1696</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi everyone,&lt;/p&gt;
&lt;p&gt;I am trying to make a custom railing, but except for the top railing, the other railings don&amp;#39;t seem to extend to the end? They seem to be stopped by a start/end profile, but somehow not getting the right distance? My start/stop profiles are 40.0x10.0, and it stops at 20.0 from the end. Turning off the start/end profile seems to make the railing extend to the end, which makes me think that is where the problem lies. See underneath for my settings.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1631719593767v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " height="175" src="/resized-image/__size/600x240/__key/communityserver-discussions-components-files/5917/settings-1.jpg" width="847" /&gt;&lt;img alt=" " height="171" src="/resized-image/__size/600x240/__key/communityserver-discussions-components-files/5917/pastedimage1631719767264v8.png" width="841" /&gt;&lt;/p&gt;
&lt;p&gt;Thanks!&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can you give priority to cached references in one or other way?</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/218481/can-you-give-priority-to-cached-references-in-one-or-other-way</link><pubDate>Mon, 23 Aug 2021 09:07:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:911547dd-ab44-4bd3-882a-21732d586913</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I was wondering how other people were handling the lack of ability to give a priority level to a reference of a clipping from a 3d. I know that you can adjust the update sequence, but sometimes I want to draw things above and below a reference. e.g. when I am drawing tile plans it would be useful if I could draw the tiles beneath the doors and such, but put annotation above everything else. Or am I the only one who has this problem?&lt;/p&gt;
&lt;p&gt;Kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Are cached references automatically not filled?</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/218408/are-cached-references-automatically-not-filled</link><pubDate>Fri, 20 Aug 2021 14:36:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1e98e189-0de1-421f-a764-0ba3f155c963</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I was wondering if cached references could be filled?&lt;/p&gt;
&lt;p&gt;I have this reference, and while set to dynamic, it is filled, but the moment I switch the reference to cached, it drops the fill. Is there any way to leave it on. The display style of the view and reference are both set to hidden line.&lt;br /&gt;This is the dynamic view:&lt;br /&gt;&lt;img height="257" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1629466133111v1.png" width="585" alt=" " /&gt;&lt;br /&gt;And this is the cached view:&lt;br /&gt;&lt;img height="241" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1629470210151v2.png" width="574" alt=" " /&gt;&lt;br /&gt;(the orange rectangle is to show that you can see through)&lt;/p&gt;
&lt;p&gt;With kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OBD sets levels to used from materials without elements</title><link>https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/217589/obd-sets-levels-to-used-from-materials-without-elements</link><pubDate>Tue, 03 Aug 2021 08:35:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1c72e6fd-c9e6-4914-b671-551a7b47c1bd</guid><dc:creator>jeroen.decooman</dc:creator><description>&lt;p&gt;Hi everyone,&lt;/p&gt;
&lt;p&gt;When opening one of my files, it sets a lot of the levels to used, without them having any elements on them. These are all the levels from the materials. A quick compress removes the used status from these levels, but when closing and reopening the file they are once more set to used. This is only in one file. Is there any way to turn this of. Below are the settings when checking for level usage.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1627979527183v1.png" alt=" " /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5917/pastedimage1627979565788v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;With kind regards,&lt;/p&gt;
&lt;p&gt;Jeroen&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>