<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>dongjin qu's Communities Activities</title><link>https://communities.bentley.com/members/a21718d5_2d00_5fab_2d00_4de4_2d00_ad5a_2d00_11023030bba0</link><description>Recent activity for people in dongjin qu's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>关于THREE_WAY_CONTROL_VALVE放置的问题</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/231200/three_way_control_valve</link><pubDate>Tue, 14 Jun 2022 03:08:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8dccef4b-4f14-47a4-9e69-86b193054a52</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;CE UP10&lt;/p&gt;
&lt;p&gt;如下链接，通过如下操作修改schema&lt;/p&gt;
&lt;p&gt;&lt;a href="/products/plant/w/plant_design_and_engineering__wiki/31155/how-to-place-three-way-control-valve-in-openplant-modeler"&gt;https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31155/how-to-place-three-way-control-valve-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;但是，对于OPM CE UP10，有其它的问题出现，如下图所示，DESIGN_LENGTH_CENTER_TO_BRANCH_END的值是生效了，但是DESIGN_LENGTH_CENTER_TO_BRANCH_END_EFFECTIVE并没有读取到DESIGN_LENGTH_CENTER_TO_BRANCH_END的值。&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1655175898607v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;请教，怎么通过修改schema，能使DESIGN_LENGTH_CENTER_TO_BRANCH_END_EFFECTIVE读取到DESIGN_LENGTH_CENTER_TO_BRANCH_END的值？&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1655176013990v2.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>关于navigator APP下架，是否有替代方案</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/230467/navigator-app</link><pubDate>Fri, 27 May 2022 09:18:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f03ba517-a3dd-461b-b18c-9edf58f85329</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;请教&lt;/p&gt;
&lt;p&gt;如下图，navigator APP已在APP store下架，那么相应的替代方案是什么？&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1653643063674v1.jpeg" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>保存spec提示“字段太小而不能接受所要添加的数据......”</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/226796/spec</link><pubDate>Wed, 09 Mar 2022 06:53:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6c565279-53a7-482f-bf4d-16b598253092</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;下午好 老师&lt;/p&gt;
&lt;p&gt;如下图所示，保存spec的时候，出现了Error&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1646808721056v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;如下图所示，根据上述错误提示，找的对应spec.MDB文件，打开表&amp;ldquo;SpecNBS&amp;rdquo;的&amp;ldquo;设计视图&amp;rdquo;，将数据类型修改为&amp;ldquo;长文本&amp;rdquo;，但是此办法并没有解决问题，请教老师，这个问题该怎么解决呢？&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1646808785702v2.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>[OPM CE U6] OPM螺栓长度计算问题</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/225628/opm-ce-u6-opm</link><pubDate>Thu, 10 Feb 2022 03:31:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8b50af08-c4f7-463b-93c7-fe77b66ca7c3</guid><dc:creator>Changsong Ling</dc:creator><description>&lt;p&gt;我的问题不是螺栓长度如何计算，我知道公式是&lt;/p&gt;
&lt;p&gt;Stud Bolt_Length = (Gasket_Thickness) + [(Flange_Thickness) x 2] + [(Nut_length) x 2] + [(BOLT_XCESS) x 2]&lt;/p&gt;
&lt;p&gt;我的问题是，我根据这个公式计算出来的值，跟OPM计算出来的值，不一样。&lt;/p&gt;
&lt;p&gt;比如DN100 CL150数据库中的相关数据如下（我的原始数据是英制，下面已经X25.4转换为公制）：&lt;/p&gt;
&lt;table width="300"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td width="63"&gt;
&lt;p&gt;flange thk&lt;/p&gt;
&lt;/td&gt;
&lt;td width="44"&gt;
&lt;p&gt;gasket&lt;/p&gt;
&lt;/td&gt;
&lt;td width="69"&gt;
&lt;p&gt;nut_length&lt;/p&gt;
&lt;/td&gt;
&lt;td width="73"&gt;
&lt;p&gt;bolt_excess&lt;/p&gt;
&lt;/td&gt;
&lt;td width="51"&gt;
&lt;p&gt;bolt_inc&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td width="63"&gt;
&lt;p&gt;23.876&lt;/p&gt;
&lt;/td&gt;
&lt;td width="44"&gt;
&lt;p&gt;1.4986&lt;/p&gt;
&lt;/td&gt;
&lt;td width="69"&gt;
&lt;p&gt;15.875&lt;/p&gt;
&lt;/td&gt;
&lt;td width="73"&gt;
&lt;p&gt;5.0038&lt;/p&gt;
&lt;/td&gt;
&lt;td width="51"&gt;
&lt;p&gt;5.0038&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;计算出来的结果是 1.4986 + (23.876+15.875+5.0038)*2 = 91.0082， 但是OPM算出来的值是99.8474， 不知道这个值是怎么算出来的。&lt;/p&gt;
&lt;p&gt;现在我手上只有U6，不知道别的版本计算结果如何。有测试过的朋友麻烦告知。谢谢。&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Questions about the preview of Auto plant components</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/228367/questions-about-the-preview-of-auto-plant-components</link><pubDate>Wed, 13 Apr 2022 03:01:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:526f32b9-c7ac-4f0c-9d25-f26e3c29a5d3</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;Hi&lt;/p&gt;
&lt;p&gt;For example, as shown in the image below, there is a preview of a ball valve in the upper right corner of the dialog.&lt;/p&gt;
&lt;p&gt;Excuse me, where is the file address of this preview image? What is the file name?&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/BAL.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>使用OPPA将UP8的workset升级倒UP9</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/212093/oppa-up8-workset-up9</link><pubDate>Tue, 06 Apr 2021 08:08:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1cc105fb-c629-446d-9d15-fd3acc0eeb63</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;下午好&amp;nbsp; 老师&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;如下图所示，使用OPPA的upgrade的命令，将UP8的workset升级为UP9的workset。（workset是以UP8的公制workset定制的，由于软件升级到了UP9，所以也想把workset升级一下）&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1617694441187v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;启动OPM发现一些问题，如下所示。&lt;/p&gt;
&lt;p&gt;1：pipeline的name不对了，property的界面也乱了&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1617696029059v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;2：如下图所示，设备的property的界面也乱了，tag栏目没了。（阀门的也是，tag没了）&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1617696109999v3.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;还有未知的问题，也就是说，通过升级workset，会出现不少未知的问题。&lt;/p&gt;
&lt;p&gt;那么，&lt;/p&gt;
&lt;p&gt;1：升级workset的正确步骤是什么？&lt;/p&gt;
&lt;p&gt;2：如果通过正确的升级步骤，出现了如上所说的问题，改怎么解决？&lt;/p&gt;
&lt;p&gt;3：软件升级到UP9，up8的workset是否可以不升级？（不升级的话，软件新增的功能可能就无法体验到了）&lt;/p&gt;
&lt;p&gt;（V8i升级CE的时候，利用upgrad的工具升级workset，也是出现了一些问题。所以花时间重新配了一遍workset）&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>怎么对“component center”进行授权</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/222549/component-center</link><pubDate>Tue, 23 Nov 2021 09:57:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0cf22fe1-ed8a-4b0b-8ed3-44d72021b885</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;请教老师&lt;/p&gt;
&lt;p&gt;如下图所示，是一个类似&amp;ldquo;族库大师&amp;rdquo;的模型管理平台，那么，在授权的时候，应该检索什么词汇才可以找到&amp;ldquo;component center&amp;rdquo;并进行授权？&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1637661288526v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPM文件发布成dgn.i.dgn，用Bentley view打开dgn.i.dgn文件，属性信息不识别</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/222320/opm-dgn-i-dgn-bentley-view-dgn-i-dgn</link><pubDate>Thu, 18 Nov 2021 06:57:22 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5c89ea70-0d50-43e1-a955-542d74ef1e17</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;下午好 老师&lt;/p&gt;
&lt;p&gt;如下所示，是文件loop11.17(1).dgn中管道属性的截图（OPM U99），&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1637217287216v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;如下图所示，是OPM UP9发布的loop11.17(1).dgn.i.dg文件中管道属性截图&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1637217377346v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Bentley view作为一款免费的看模型的软件，对于非设计工程来讲是一个非常必需的软件，按照软件的设计，是可以读取imodel文件中所有的属性信息。&lt;/p&gt;
&lt;p&gt;请教老师 该问题怎么解决？&lt;/p&gt;
&lt;p&gt;如下是两个文件的下载地址&lt;/p&gt;
&lt;p&gt;链接：&lt;a href="https://pan.baidu.com/s/1gGObof_3QUeJoKDHm3JD9g"&gt;pan.baidu.com/.../1gGObof_3QUeJoKDHm3JD9g&lt;/a&gt; &lt;br /&gt;提取码：yb11&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>关于OPM UP9碰撞检查的问题</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/220808/opm-up9</link><pubDate>Fri, 15 Oct 2021 08:42:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8bed8da0-c36b-4be5-8019-cdcb1386a05d</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;下午好 老师&lt;/p&gt;
&lt;p&gt;如下图，是一个碰撞检查的结果，&amp;ldquo;元素标签A&amp;rdquo;显示了特定的内容，请教老师，&lt;span&gt;元素标签A显示的规则，是在那个schema中的那个class下定义的？&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1634287322480v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPM UP Clip Volume的问题</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/220004/opm-up-clip-volume</link><pubDate>Mon, 27 Sep 2021 10:00:21 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:46f997c0-8167-4d98-9663-1807cd02e105</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;请教老师&lt;/p&gt;
&lt;p&gt;软件 OPM， 版本：UP9&lt;/p&gt;
&lt;p&gt;如下图，Clip Volume范围框外的模型，是不应该显示的，但是在UP9里面是显示的，请教老师是哪里出现的问题？&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1632736602616v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Problems with OPM up9 clip volume</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/220052/problems-with-opm-up9-clip-volume</link><pubDate>Tue, 28 Sep 2021 00:54:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a4c66791-ca26-4a3b-ad1b-7f5e37b44e72</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;Ask the teacher&lt;/p&gt;
&lt;p&gt;Software OPM, version: up9&lt;/p&gt;
&lt;p&gt;As shown in the following figure, the model outside the clip volume scope box should not be displayed, but it is displayed in up9. Please ask the teacher where the problem occurred?&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/pastedimage1632790591565v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>ISO报表设置问题</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/219854/iso</link><pubDate>Thu, 23 Sep 2021 03:01:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c2580d10-2d4a-47ff-9e6d-bc7c18ae5750</guid><dc:creator>Wu Qiaoxin</dc:creator><description>&lt;p&gt;请问老师在ISO中修改报表时，我想将管道长度用M表示，在表达式中&amp;nbsp; COLUMN = 15: C : QUANTITY/1000，这样可以实现以M为单位显示，但是小数点后会多六位显示，&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1632366124550v1.png" alt=" " /&gt;我想以M为单位显示但是小数点精确至两位或者不显示小数点，这个该如何实现呢？另外老师现在有没有一个最新的报表的编辑字段注释，很多都还是按照V8的去编辑，不清楚现在CE的最新逻辑&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>管道捕捉</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/219863/thread</link><pubDate>Thu, 23 Sep 2021 07:39:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dcae8f2e-8031-415c-8dd1-61b9bad042f1</guid><dc:creator>N Chao</dc:creator><description>&lt;p&gt;请问下，管道默认捕捉管道中心，想捕捉管道边缘。请问是在哪里设置？谢谢&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>关于 catalog editor UP9 repair sys id无效的问题</title><link>https://communities.bentley.com/communities/other_communities/chinafirst/f/openplant/219197/catalog-editor-up9-repair-sys-id</link><pubDate>Wed, 08 Sep 2021 09:07:01 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:70775df6-a645-44fe-90af-e9e66963383e</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;上午好老师&lt;/p&gt;
&lt;p&gt;如下图所示&lt;/p&gt;
&lt;p&gt;catalog在进行repair sysid时，下方提示成功，但是打开catalog.MDB文件，SYS_ID一栏是空值，即&lt;span&gt;repair 工具无效怎么解决？&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;当点击&amp;ldquo;renew&amp;rdquo;之后，打开catalog.MDB文件，SYS_ID一栏是有值的&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343516/pastedimage1631091836015v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>About invalid catalog editor up9 repair sys ID</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/219204/about-invalid-catalog-editor-up9-repair-sys-id</link><pubDate>Wed, 08 Sep 2021 09:41:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cbc97fa9-ca1b-4840-a658-334fd3671188</guid><dc:creator>dongjin qu</dc:creator><description>&lt;p&gt;Hi&lt;/p&gt;
&lt;p&gt;As shown in the figure below&lt;/p&gt;
&lt;p&gt;When catalog performs the repair SYSID, the following prompt indicates success, but when the catalog.mdb file is opened, the SYSID column is empty, that is, the repair tool is invalid. How to solve it?&lt;/p&gt;
&lt;p&gt;After clicking &amp;quot;renew&amp;quot;, open the catalog.mdb file, and the SYSID column has value&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/pastedimage1631093762587v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>