RE: OpenPlant Isometric Manager Administration
Tuan Le
Thanks heaps, Harpreet. That's good news indeed and I will soldier on with my investigation then.
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: How can I open Descartes SS6 in Openplant SS6?
Tony D
Hello Erick, First things first - make sure you installed Bentley Descartes for MicroStation V8i (SELECTseries 6) build 08.11.09.720. This is the layered Descartes for use inside of MicroStation and OpenPlant Modeler. Once this is installed, you need…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OpenPlant Product Compatibility
Rahul Kumar
Here compatibility across different release versions of OpenPlant Product with Operating Systems, ProjectWise and various Database types is presented. The compatibility matrixes are available in pdf format thus could be downloaded. Follow the link below…
9 months ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
RE: OPPPID Drawing Revision
Bhadresh Nanavati
Thanks very much for your help. I wish you had answered this before as I was told that it is a defect issue by the other support person.
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: OPPPID Drawing Revision
Bhadresh Nanavati
Thanks for your help. It did work. You have the best support knowledge.
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: OPPPID Drawing Revision
Tony D
Hello Bhadresh, In order for the PID_DOCUMENT class to support REVISION property with alpha characters you will need to do the following. Launch Class Editor. Load the OpenPlant schema located here (by default in Windows 7) "C:\ProgramData\Bentley…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: Where i find the different gauges in OpenPlant Modeler
Markus Wilbers
Yeah, thats helps me ;D sry i had say this more clear i dont want different graphics in OPM i want difference symbols on the isometric, and with the solution from Kumar i had difference classes with difference symbols in the isometric. Thanks all…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: Pressure Relief Valves with different inlet / outlet pressures OPM v440
Grant Wheatley
Thank you Harpreet all working, I was heading down this process but wiki clarified the final part.
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: How to prepare a catalog of Basket and T-Strainers ?
Kestutis Mitkus
Hello Przemysław Chmura, Exact information about fields contained in factory-shipped Bentley catalogs and specifications can be found in C:\Program Files (x86)\Bentley\OpenPlantModeler V8i\Documentation\OPSpecGen.chm Help file. Open this file and go…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: Questions about OpenPlant PID
Tony D
Hello and thank you for your inquiry. It would be helpful if you could identify yourself. In response to your questions see below. 1. OpenPlant PID does store Control/Input for related instruments. This is currently not stored in the database. …
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
To Modify Pipeline Tag Name in OpenPlant Modeler
Rahul Kumar
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Properties Subarea: - Original Author: Rahul Kumar, Bentley Product…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Modify Default Outside Diameter Value for End Types in OpenPlant Modeler
Rahul Kumar
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant Specification Generator Subarea: - Original Author: Rahul…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Populate Gridlines Reference Dimensions Automatically
Rahul Kumar
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 & 08.11.09.564 Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
RE: How to disable prompt while applying Batch process of Autoplant P&ID to OPPID conversion.
Tony D
Krishna, This is due to an incorrect property mapping in the AutoPLANT_PID_Conversion schema. To resolve this you will need to determine which page connector class is being used in your AutoPLANT PID drawings. An example of this would be "tofrom2…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to Use Grid Lines in OpenPlant Isometrics Manager
Abhijit Bute
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
>