Hi Sedat Alis,
Glad to hear you have worked around the issue and that Jon and I were able to help in the process.
Thank you both!Bob
Not all loaded MDL applications show up in the MDL Applications dialog box. In MicroStation V8 you can key-in: set rm 0. This will display a full list of loaded MDL application resources and relative paths loaded from. When doing so you…
I have reviewed the native call stack and it would appear that a PowerSelector synchronization event on ModelRefActiviated is upating its ModelSelections listbox and crashing on retrieving color descriptor information for synchronization…
Can you zip and post this file to review?
Wrote a mini-dump type 0x7 to "C:\Users\Dilemma\AppData\Local\Temp\Bentley\AECOsimBuildingDesigner\8.11\fbTdNrfM_E-UCF4EGEaZbQ\MiniDump.dmp".
Thank you,Bob
Daniel Bollavarapu said:Complete project must contain dialog source .r file for migration ?
As I wrote above: You need complete project with all source codes. Rsc files are not source codes, they are compiled from .r (plus other like .h) files using resource…
I am tagging Yongan.Fu to see if he has or knows of any code examples (or issues) related to Reading and Writing UNICODE values between MicroStation and Microsoft Access Databases. I presume he may have his own experience(s) to pass along…
Sedat Alis said:But it returns (char *) data type as query result which is limited to 255 ASCII characters.
MicroStation (and ABD) V8 are both capable of performing the most common needed API calls for reading and writing "character data…