<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Karley Stracke's Activities</title><link>https://communities.bentley.com/members/b14ac6d0_2d00_9593_2d00_45af_2d00_b34e_2d00_5dc2ac6e0519</link><description>Karley Stracke's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>[GenerativeComponents in OBD] Node types, Graph and Transaction doesn&amp;#39;t show up</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/229307/generativecomponents-in-obd-node-types-graph-and-transaction-doesn-t-show-up</link><pubDate>Wed, 04 May 2022 05:01:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c5030b3d-0e1d-41c3-bbdc-fc440e65beee</guid><dc:creator>netsonic</dc:creator><description>&lt;p&gt;&lt;span&gt;OpenBridge Designer CE 2021 Release 2, &lt;a href="/products/products_generativecomponents/f/generativecomponents---forum"&gt;GenerativeComponents&lt;/a&gt; 10.09.01.06&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Node types is blank, hit &amp;quot;Graph&amp;quot; or &amp;quot;Transaction&amp;quot;, no corresponding window shows up.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/960x720/__key/communityserver-discussions-components-files/5930/1030.png" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/960x720/__key/communityserver-discussions-components-files/5930/8737.png" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/960x720/__key/communityserver-discussions-components-files/5930/7288.png" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Support line not valid for bearing</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/229912/support-line-not-valid-for-bearing</link><pubDate>Mon, 16 May 2022 17:54:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7e7771a1-3a8b-4a91-b497-f5f9c1617342</guid><dc:creator>Diego Veloso</dc:creator><description>&lt;p&gt;Hello there. I&amp;#39;m am trying to place bearing in two different support lines, but after I place the bearing in one, I cant place those in the other supportline, I receive the message that the supportline is not a valid element for tool. What am I doing wrong here?&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5930/pastedimage1652723634540v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Leap Steel Live Load Reaction Report Different From Shear Diagram</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/217046/leap-steel-live-load-reaction-report-different-from-shear-diagram</link><pubDate>Thu, 22 Jul 2021 14:06:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:70af1ba5-9a70-498e-b9ea-ded8afdb301b</guid><dc:creator>Ran Ji</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;I&amp;#39;m&amp;nbsp;trying to get the live load reaction for&amp;nbsp;a 3 span continuous span bridge and noticed the live load reaction values from the report is different from the static analysis diagram.&lt;img alt="LL Shear Diagram" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5930/Shear-Diagram.png" /&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img alt="Support Reaction Report" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5930/Support-Reaction-Report.PNG" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt="Lane loading Details" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5930/Lane-Loading-Details.PNG" /&gt;&lt;/p&gt;
&lt;p&gt;The support reaction report and lane loading details report show the same LL reaction 92.594 kip, while the shear diagram show a value of 61.4 kip. Is there any specific reason for this discrepancy?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Live load application to straddle bent</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/228837/live-load-application-to-straddle-bent</link><pubDate>Fri, 22 Apr 2022 22:48:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d8d1de01-acc0-4a54-b629-1a7d77898f39</guid><dc:creator>John Lange</dc:creator><description>&lt;p&gt;I am designing a post-tensioned straddle bent. The superstructure has 6 girder lines. Is it possible to define a design truck using fixed axle spacing so it appears &amp;quot;stationary&amp;quot; to reflect the live load reactions from girders to a post-tensioned straddle bent? For example the bearing locations = axle fixed spacing from the left end are: G1-G2-G3-G4-G5-G6&amp;nbsp; =&amp;nbsp; 63.5&amp;#39;-7.5&amp;#39;-7.5&amp;#39;-7.5&amp;#39;-7.5&amp;#39;-7.5&amp;#39;.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>RC Slab bridge Design (LEAP Bridge Concrete)</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/228451/rc-slab-bridge-design-leap-bridge-concrete</link><pubDate>Thu, 14 Apr 2022 13:27:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b1df7e77-a659-4fba-8613-a1633a91d372</guid><dc:creator>Nicole Magloire</dc:creator><description>&lt;p&gt;&lt;br /&gt; I am currently using the LEAP Bridge Concrete software and I require guidance in understanding the user interface and how it relates to conducting the load/analysis and design components.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;These are the steps that I have followed:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;I have modelled a simple deck slab bridge using Openbridge Modeler and exported it into Leap Bridge Concrete&lt;/li&gt;
&lt;li&gt;From there I adjusted the geometry (cross sections in particular) as required by my design&lt;/li&gt;
&lt;li&gt;I then moved on to the Load/Analysis Tab&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Key problem area&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;In applying the various loads &amp;nbsp;(Dead, Live, Pedestrian), is it required that data should be input for each load combination limit state (service 1, service 3) as well as each case (Initial and final)?&lt;/li&gt;
&lt;li&gt;Additionally, how exactly are these combinations being applied to the structure?&lt;/li&gt;
&lt;li&gt;Also, is there a way to see exactly how the loads interact with the structure when applied outside of simply populating the resulting stresses, forces, etc.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;In addition, are there any guidance videos that can be used to help with better understanding how the software can be used to design bridges with simple deck slabs?&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Any assistance will be greatly appreciated.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>LEAP Bridge Concrete files will not open after saving and coming back.</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/145681/leap-bridge-concrete-files-will-not-open-after-saving-and-coming-back</link><pubDate>Mon, 15 Jan 2018 20:42:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5e569e4a-43eb-411e-b5d3-ebf127a5c6f4</guid><dc:creator>Evan Jones</dc:creator><description>&lt;p&gt;We&amp;#39;ve run into an issue where files created in the Precast/Prestressed Girder module in LEAP Bridge Concrete sometimes are not able to be opened after we save and come back to our work. We attempt to open the file and it will begin to load, then it stops and nothing happens.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Is this a known issue? Are we perhaps saving wrong?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Evan Jones&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Variables of the placed custom substructure resets to default value when editing other bridge elements</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/227220/variables-of-the-placed-custom-substructure-resets-to-default-value-when-editing-other-bridge-elements</link><pubDate>Fri, 18 Mar 2022 04:40:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ad838d99-7e44-46ac-aa88-f47ee6d4efec</guid><dc:creator>Crisanto Aquino</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;When i place a parametric cell as a substructure on a model and if i modify for example my girders/beams&amp;nbsp;or decks, what OBM does is it also resets the variables i&amp;#39;ve placed on my parametric cell. Its not ideal since i&amp;#39;m working on a complex parametric cell with alot of variables and if i change something on the bridge, those variables that i placed are being set to its default value and i have to set them again.&lt;br /&gt;&lt;br /&gt;One other issue i noticed is that if i added an &amp;#39;expression&amp;#39; to my variables and place the cell in OBM and change the variable, it doesn&amp;#39;t automatically calculate the expression based on the value i input.&lt;br /&gt;&lt;br /&gt;Another thing is i created my custom substructure with different levels for each part, but when i placed them and cut a section all of the linework are set to &amp;#39;default&amp;#39; level which i think is of not a good workflow to use.&lt;br /&gt;&lt;br /&gt;I hope the OBM team will take a serious look at this issue because in reality the default templates within OBM is not enough, in my experience we had to create a custom substructure every time because of the complexity of the bridge design.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Custom barrier using PLACE PATH</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/226983/custom-barrier-using-place-path</link><pubDate>Mon, 14 Mar 2022 02:42:21 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dc2e8aea-7266-483f-9530-622b380d8f1b</guid><dc:creator>John Patrick Valdez</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I&amp;#39;m new on using OpenBridgeModeller. I&amp;#39;m trying to place a custom barrier by using PLACE PATH. I created the custom barrier in the AuxLib.cel. Its showing on the list (see image below), but when I try placing it, its not appearing on the model. Hope anyone can help me with this.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;P.S. I&amp;#39;m not using the PLACE BARRIER command because I&amp;#39;m trying to create the barrier layout per specific length. Using the PLACE BARRIER make the barriers all through out the bridge without any joints/gap.&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5930/pastedimage1647225570243v3.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>