<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Dylan Kennedy's Activities</title><link>https://communities.bentley.com/members/bc3cdc7b_2d00_5165_2d00_459c_2d00_8d2c_2d00_56e960b1f5d1</link><description>Dylan Kennedy's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to save reinforcement design? LEAP Concrete Substructure</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/239632/how-to-save-reinforcement-design-leap-concrete-substructure</link><pubDate>Fri, 16 Dec 2022 20:06:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b421495d-1706-4d69-a37a-4c0f4a675e57</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Hello,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I am working in OpenBridge (10.9.1.15) StandAlone LEAP Concrete. I have a question about how to save reinforcement design in LEAP Concrete. When I am working in Substructure, I generate loads, run analysis and then design the reinforcement in Cap and Column. I&amp;nbsp;then update the LEAP Bridge Concrete Model. Then I move to the next bent and design the reinforcement in the same way. When I return to the first bent, all of the analysis and reinforcement design is gone. Is there a way to permanently save/export these designs?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks,&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Inverted T Beam- Ledge Reinforcement</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/238075/inverted-t-beam--ledge-reinforcement</link><pubDate>Tue, 08 Nov 2022 17:20:23 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:80a6ad16-d37c-4446-86d5-9633bea40e98</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Hello,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;How do I control the&amp;nbsp;spacing of the ledge reinforcement for an inverted T beam? I do not see a dialog box, I&amp;#39;m using LEAPBridge Concrete V 21.00.00.24.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5930/6403.Capture.PNG" /&gt;&lt;/p&gt;
&lt;p&gt;Thanks,&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Post Tension Straddle Bent Design</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/241608/post-tension-straddle-bent-design</link><pubDate>Mon, 13 Feb 2023 17:58:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d4d05ac6-f649-4de9-96f6-88b0b0f16979</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Is it possible to design post tensioned straddle bents in OpenBridgeDesigner/LeapConcrete? If so is there any tutorials on how to perform the design?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>LEAP Concrete Concrete Strength Issue</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/239381/leap-concrete-concrete-strength-issue</link><pubDate>Fri, 09 Dec 2022 23:18:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ead05ec0-b528-4e97-9a71-561f2e91c7e1</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;I am working in LEAP through&amp;nbsp;the OpenBridge Designer BIM workflow. I have changed the concrete strength for an element in OpenBridge Modeller, but it isn&amp;#39;t updating in LEAP Concrete. Please advise.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5930/pastedimage1670628014261v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;OBM&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5930/pastedimage1670628111931v2.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;LEAP&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Steel Sections for PowerDraft Connect Edition</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/228409/steel-sections-for-powerdraft-connect-edition</link><pubDate>Wed, 13 Apr 2022 19:02:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8b8cafe6-554c-4296-93c7-361aeffc3e09</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Is there a steel section cell library compatible with MicroStation Connect Edition available through Bentley?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Let me Help You</title><link>https://communities.bentley.com/achievements/687f4b6d-e18a-4e55-836c-49926ca2c9d9</link><pubDate>Wed, 14 Jul 2021 06:00:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e338a651-7a81-4a14-bbc5-fad91edb1afd</guid><dc:creator /><description>Answer a question that is verified as helpful or correct.</description></item><item><title>OpenBridge Modeler Crash- Modifying Beam Layout</title><link>https://communities.bentley.com/products/bridge_design___engineering/f/bridgemaster-lars-leap-openbridge-rm-forum/216544/openbridge-modeler-crash--modifying-beam-layout</link><pubDate>Mon, 12 Jul 2021 14:57:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e7441832-488e-49c6-a0c6-e2a55d34e7d4</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Hello,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I am working in OpenBridge Modeler Connect Edition (10.08.02.55) through OpenBridge Designer (&lt;span&gt;10.08.02.10)&lt;/span&gt; and am experiencing an issue which causes the software to crash. I am attempting to model a bridge with different numbers of beams in the different spans. In this case spans 1,2, 5, &amp;amp; 6 have 16 beams and spans 3 and 4 have 14 beams. When I model the bridge with all of the spans having the same number of beams, the layout generates successfully. However, when I attempt to change some of the spans to a different number, the program crashes. See attached. If I press ignore, the program instantly crashes if I attempt to change any of the inputs for the 14 beam spans. Does anyone have any familiarity with this issue?&lt;/p&gt;
&lt;p&gt;&amp;nbsp; &amp;nbsp;&lt;img alt=" " height="497" src="/resized-image/__size/3200x2400/__key/communityserver-discussions-components-files/5930/8715.obm-crash.png" width="1066" /&gt;&lt;/p&gt;
&lt;p&gt;Thanks,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Dylan&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>[CONNECT] PowerDraft Batch Process Utility Missing</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/215604/connect-powerdraft-batch-process-utility-missing</link><pubDate>Mon, 21 Jun 2021 15:58:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5eff4bce-5fc7-4c4d-a632-b1401d1988cd</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Hello,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I am using&amp;nbsp;PowerDraft connect edition, I am trying to create a batch process, however I cannot find the batch processing utility. I have looked in the backstage &amp;quot;Tools&amp;quot; however it isn&amp;#39;t there.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/3200x240/__key/communityserver-discussions-components-files/273/1856.Capture.PNG" /&gt;&lt;/p&gt;
&lt;p&gt;Is there something I need to do to be able to see the batch process, or is there an some other reason the batch process isn&amp;#39;t available?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Dylan&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Typo in STAAD.Pro Manual (Code check for groups)</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/215020/typo-in-staad-pro-manual-code-check-for-groups</link><pubDate>Tue, 08 Jun 2021 14:35:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4a3afe5b-710f-4f9d-944f-10c8030f7f16</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;On page 731 of the STAAD.Pro Technical Reference Manual, the code checking command is listed as &amp;quot;CODE CHECK _GROUPNAME&amp;quot;.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5932/pastedimage1623161668268v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Attempting to run this command will result in a syntax error.&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/3200x2400/__key/communityserver-discussions-components-files/5932/7271.Capture.PNG" /&gt;&lt;/p&gt;
&lt;p&gt;On the &lt;a href="/products/ram-staad/w/structural_analysis_and_design__wiki/29134/check-code-command-for-group"&gt;STAAD Wiki&lt;/a&gt; the correct code checking command is listed as &amp;quot;&lt;span&gt;CHECK CODE MEMB _TEST&amp;quot;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;span&gt;Running this command will result in a successful check.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Thanks,&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Creating and using PowerDraft Connect Edition OLE object in Mathcad Prime 6 issue</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/214110/creating-and-using-powerdraft-connect-edition-ole-object-in-mathcad-prime-6-issue</link><pubDate>Wed, 19 May 2021 13:19:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:72a83867-c4af-48eb-85ba-dbf4d4680ebc</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;I am having an issue creating an OLE object of a dgn in mathcad Prime 6. I am using Microstation PowerDraft Connect Edition. I followed the steps outlined here &lt;a href="https://communities.bentley.com/products/microstation/w/microstation__wiki/16622/how-to-paste-a-microstation-dgn-file-into-mathcad"&gt;communities.bentley.com/.../how-to-paste-a-microstation-dgn-file-into-mathcad&lt;/a&gt;. At first I was getting a permissions issue that required I be an administrator to run the &amp;quot;mdl load oleserve&amp;quot; command.&lt;/p&gt;
&lt;p&gt;I changed PowerDraft to run as Admin, and was able to complete the steps on the PowerDraft side of things. However, when I attempted to create the object in Mathcad, it worked, but I could not edit the MicroStation file. When I open the file I cannot save any changes I make, see below.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/273/pastedimage1621430321227v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Has anyone else had a similar issue?&lt;/p&gt;
&lt;p&gt;Thank you very much.&lt;/p&gt;
&lt;p&gt;Dylan&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>STAAD PRO Plate Error - BADLY SHAPED, WARPED, NOT CONVEX, OR NOT NUMBERED COUNTER-CLOCKWISE</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/209418/staad-pro-plate-error---badly-shaped-warped-not-convex-or-not-numbered-counter-clockwise</link><pubDate>Fri, 05 Feb 2021 16:22:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a39a481b-21f2-4b0d-9779-edb5df3399c0</guid><dc:creator>Dylan Kennedy</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I created this model wit the STAAD Pro physical modeler, when I loaded it into the analytical modeler and attempted to run it I received the &amp;quot;Plate Error - BADLY SHAPED, WARPED, NOT CONVEX, OR NOT NUMBERED COUNTER-CLOCKWISE&amp;quot; error. I have reviewed the &lt;a href="/products/ram-staad/m/structural_analysis_and_design_gallery/257477"&gt;Plate Element Modelling Rules&lt;/a&gt;, however outside of the &amp;quot;Not numbered counter-clockwise&amp;quot; I cannot see what would be wrong. I have attached the input file:&lt;/p&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5932/Plate-Model-Test.STD"&gt;communities.bentley.com/.../Plate-Model-Test.STD&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thank you for your assistance,&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Fri, 05 Feb 2021 00:47:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cb46e889-b752-4c5c-9e02-2ef23fc682d2</guid><dc:creator /><description>Ask a question in a forum.</description></item></channel></rss>