<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Peter Sande's Activities</title><link>https://communities.bentley.com/members/c316a311_2d00_a325_2d00_4121_2d00_b4cc_2d00_6dd34d231a48</link><description>Peter Sande's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>OPM - SS6 - How to Assign Level for GENERIC Equipment Tag Using Named Expression</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/185019/opm---ss6---how-to-assign-level-for-generic-equipment-tag-using-named-expression</link><pubDate>Wed, 04 Sep 2019 07:36:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:01a88413-f333-422e-9059-dac743f7cac3</guid><dc:creator>sts</dc:creator><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;When you use the named expression to assign a device level tag using the term named for tank, heat exchanger or other type, that&amp;#39;s fine.&lt;br /&gt;Example: Tank-T200 000 or Pump-P200 100&lt;/p&gt;
&lt;p&gt;But when you use generic material, it&amp;#39;s not good, because all the generic material is placed at the same level (without tag).&lt;br /&gt;Level: Equipment&lt;/p&gt;
&lt;p&gt;How to assign a level to a generic device tag using a named expression&lt;br /&gt;Example: Equipment-S-200 450&lt;/p&gt;
&lt;p&gt;Best Regards&lt;/p&gt;
&lt;p&gt;Salim&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Topworks Angle</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/182246/topworks-angle</link><pubDate>Tue, 09 Jul 2019 14:41:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d4fc93dd-7be7-40da-9461-f610fe6469c1</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;How to implement TOPWORK_ANGLE in AutoPlacement of topworks in OpenPlant Modeler CE?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Orifice Assembly</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/208938/orifice-assembly</link><pubDate>Tue, 26 Jan 2021 09:20:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3fc57090-ff7b-41a9-aff4-780cab2d457d</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;We have an orifice assembly as in attached image.&lt;/p&gt;
&lt;p&gt;Can anybody help us make this as a Custom OPM_component, with Isometric symboloy&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/Snag_5F00_185c7543.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Any help is much appreciated&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>BleedRing w 45deg flg outlet ISO symbol</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/208937/bleedring-w-45deg-flg-outlet-iso-symbol</link><pubDate>Tue, 26 Jan 2021 09:13:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3463635b-4337-4d19-93c0-ca4f8e2f853a</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;We have trouble generating an ISO symbol for this. Can anybody pls help. See attached image&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/DripRing45Deg.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;All help is much appreciated&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPM CE Isometric Bolts&amp;amp;Gaskets</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/204814/opm-ce-isometric-bolts-gaskets</link><pubDate>Wed, 21 Oct 2020 09:47:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1c48c1b9-8db2-4a02-bb9d-c794564bae57</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;Qeustion:&lt;/p&gt;
&lt;p&gt;When having two lines connecting w a flange connection, what rules apply to which line contains the Gasket and bolts ?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Map RF/FF issue</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/204156/map-rf-ff-issue</link><pubDate>Wed, 07 Oct 2020 05:49:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ea132f24-7837-4b8b-b8bd-cff16daf1f76</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;We have the following issue with Spectacle Blinds&lt;/p&gt;
&lt;p&gt;Rule:&lt;/p&gt;
&lt;p&gt;(OPM_MATCH_PROPERTY_MAP_FACING = C;D|E;F|RAISED_FACE;FLAT_FACE|FLAT_FACE;RAISED_FACE|RAISED_FACE;RAISED_FACE|FLAT_FACE;FLAT_FACE)&lt;/p&gt;
&lt;p&gt;This works fine with mating flanges RF/FF.&lt;/p&gt;
&lt;p&gt;When placing a Spectacle Blind between a RF / FF flange pair, it does not work.&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/pastedimage1602049718409v1.png" alt=" " /&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/pastedimage1602049729457v2.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CUSTOM COMPONENT CAN&amp;#39;T BE PLACE FLANGE</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/203713/custom-component-can-t-be-place-flange</link><pubDate>Fri, 25 Sep 2020 08:40:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1dac9205-04d5-47e2-84ef-2a3af4531f50</guid><dc:creator>修偉 柳</dc:creator><description>&lt;p&gt;HELLO，I CREATED NEW CUSTOM COMPONENT FOR FLOW METER AND FOLLOW THE STEPS BELOW：&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;"&gt;1.&lt;span&gt;Click&amp;nbsp;&lt;/span&gt;&lt;strong&gt;Define Origin&lt;/strong&gt;&lt;span&gt;&amp;nbsp;to define the origin point of the component.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;"&gt;&lt;span&gt;2.&lt;/span&gt;Define the connect points for both the ports. Click Define connect points and select the left port of the valve followed by defining the direction. As soon as MAIN_PORT is defined it asks to define the RUN_PORT.&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;Similarly, select the right port and define the direction by moving the cursor towards right.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;"&gt;3.Once the Origin &amp;amp; Connect points are defined&amp;nbsp;&lt;strong&gt;Create Component&lt;/strong&gt;&amp;nbsp;button is enabled automatically. Click&amp;nbsp;&lt;strong&gt;Create Component&lt;/strong&gt;&amp;nbsp;to finish the component creation.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;"&gt;4.&lt;span&gt;It opens up the component placement dialog. Fill in the required fields and click the Green Check button to complete the placement of component.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#000000;"&gt;BUT WHEN I PLACE FLANGE TO FLOW METER，JUST ONE END CAN BE PLACE LIKE PICTURE.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#000000;"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/port.JPG" /&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Isometric Manager Error in fetching Data</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/202921/isometric-manager-error-in-fetching-data</link><pubDate>Wed, 09 Sep 2020 06:57:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3e6d3b18-895c-4249-8752-d44b123b8bd3</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;We have an issue when creating and then trying to generate Iso for newly created sheet. More than often we get the message &amp;#39;Error in fetching data&amp;#39; (See attached image)&lt;/p&gt;
&lt;p&gt;If closing isometric manager and then generating same from Pipeline Manager it works.. Why does this happen?&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5927/pastedimage1599634649832v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Isometric Manager Connecting lines</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/202919/isometric-manager-connecting-lines</link><pubDate>Wed, 09 Sep 2020 06:45:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:07aff5d7-8f00-4a18-9e00-aa25874e2bc7</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;We have an issue with Isometric showing a multitude of components for connecting lines. Know there is a setting for number of connecting components somewhere. See attached image&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5927/pastedimage1599633854662v1.jpeg" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Any help is much appreciated&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPM CE Drop Element</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/182513/opm-ce-drop-element</link><pubDate>Mon, 15 Jul 2019 09:21:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:485b6b8a-7300-4dc1-9d19-0a147053300d</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;How to drop an &lt;span&gt;Application Element&lt;/span&gt; in OPM CE?&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5927/7115.2019_2D00_07_2D00_15_5F00_11_2D00_16_2D00_10.jpg" alt=" " /&gt;&lt;img src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5927/4744.Snag_5F00_57abbaf8.png" alt=" " /&gt;&lt;img src="/resized-image/__size/640x480/__key/communityserver-discussions-components-files/5927/2474.Snag_5F00_57ac9de6.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;After Drop Application Element, Graphics disappear. This works fine in OPM v8i&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Isometric Manager problem solving</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/202041/isometric-manager-problem-solving</link><pubDate>Thu, 20 Aug 2020 07:25:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:32d40a48-f0f2-4a28-be11-db0b4daa3fa0</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;&lt;span style="color:#ff0000;"&gt;Win10&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;"&gt;OPM Upd7&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Have various connection issues when trying to produce Iso&amp;#39;s&lt;/p&gt;
&lt;p&gt;Is there a way to select a component by GUID&lt;/p&gt;
&lt;p&gt;A typical error message from production log&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#0000ff;"&gt;[20.08.2020 09:11:24] Pre-processing: Convert EC to Isometric Dataset&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt;------------------------------------------------------------------------------------------------------------------------&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt; Error: Connectivity Failed&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt; Pipe[PIPE]bbf4999d-78aa-40b1-a8b5-2578aa403d42&lt;/span&gt;&lt;br /&gt; &lt;br /&gt;&lt;span style="color:#0000ff;"&gt;Unconnected Components&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt; at Bentley.Isometrics.Converter.Connectivity.FillDataset(IsometricDataset ds)&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt; at Bentley.Isometrics.Converter.DataProcessor.ProcessDataset(IsometricDataset dsData)&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt; at Bentley.Isometrics.Converter.DatasetManager.GetDataset(ECInstanceList ecData, IECKey RootClassKey, String IsometricName, RepositoryConnection connection)&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;"&gt; Error:Unconnected Components&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;With these types of errors, typically IsoMetricManager will Crash&lt;/p&gt;
&lt;p&gt;By the way:&lt;/p&gt;
&lt;p&gt;All connectivity checks are ok&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPM CE Display Units</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/186643/opm-ce-display-units</link><pubDate>Tue, 08 Oct 2019 15:06:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6ea08277-8b3f-4d82-aaad-f30051438af9</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;How to modify display Units ?&lt;/p&gt;
&lt;p&gt;For any property we need to do math on, we would like a &amp;#39;unitless&amp;#39; display and export.&lt;/p&gt;
&lt;p&gt;Example:&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/2019_2D00_10_2D00_08_5F00_17_2D00_02_2D00_02.jpg" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;In this example we want to remove the &lt;span style="color:#ff0000;font-size:150%;"&gt;kg&lt;/span&gt; and &lt;span style="color:#ff0000;font-size:150%;"&gt;mm&lt;/span&gt; designations&lt;/p&gt;
&lt;p&gt;Thanks in advance for any help on this.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>guid keyin</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/199847/guid-keyin</link><pubDate>Sun, 05 Jul 2020 13:20:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:21a0e60d-e2a6-443e-98c0-ec4d95562f8f</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;In Isometric Production log get error:&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:&amp;#39;courier new&amp;#39;, courier;"&gt;[05.07.2020 15:01:47] Pre-processing: Convert EC to Isometric Dataset&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:&amp;#39;courier new&amp;#39;, courier;"&gt;------------------------------------------------------------------------------------------------------------------------&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:&amp;#39;courier new&amp;#39;, courier;"&gt; Error: Connectivity Failed&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:&amp;#39;courier new&amp;#39;, courier;"&gt; Weld Neck Flange[WELD_NECK_FLANGE]5b9b7e25-b87c-4541-818c-1b18beedef41&lt;/span&gt;&lt;br /&gt; &lt;br /&gt;&lt;span style="font-family:&amp;#39;courier new&amp;#39;, courier;"&gt;Unconnected Components&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:inherit;"&gt;Is there an easy way to locate component in question by a key-in, as guid and line number is only information given?&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:inherit;"&gt;So basically question is how to locate / select / highlight a component when only guid is known?&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:inherit;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:&amp;#39;courier new&amp;#39;, courier;"&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>DBB Monoblock</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/199409/dbb-monoblock</link><pubDate>Thu, 25 Jun 2020 11:22:33 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3229096d-e71a-48b8-b3ef-8924c3ea5453</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;We need to define this Double block and bleed Valve in two variants (See image).&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;1)Flanged inlet and Screwed outlet as shown (Bolting like a Blind Flange)&lt;/li&gt;
&lt;li&gt;2)Variant with Flanged inlet / oulet (Wafer Type)&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/Snag_5F00_9cabf2c.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPM CE User Component</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/197830/opm-ce-user-component</link><pubDate>Wed, 27 May 2020 06:21:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1336557b-169a-4aff-9e8f-eca610871f91</guid><dc:creator>Peter Sande</dc:creator><description>&lt;p&gt;Level Transmitter as per attached image&lt;/p&gt;
&lt;p&gt;Any suggestions on how to define as User component?&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5927/pastedimage1590560394886v1.png" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;Any Help is much appreciated&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>