<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Patrick Coyne's Activities</title><link>https://communities.bentley.com/members/c675c0a7_2d00_421d_2d00_4cef_2d00_8360_2d00_8410cfb3116b</link><description>Patrick Coyne's recent activity</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Station/Offest using Civil AccuDraw</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/132749/station-offest-using-civil-accudraw</link><pubDate>Fri, 10 Mar 2017 21:18:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bfc1ab5f-f7b3-462a-a22f-9bfc99d8aca7</guid><dc:creator>Mike Archer</dc:creator><description>&lt;p&gt;I&amp;#39;m using Geopak 08.11.09.872 and I&amp;#39;m trying to place a line using Civil AccuDraw (Station-Offset). &amp;nbsp;I want to place it on my alignment at Station 162+50, Offest 0 but when I activate the draw command the alignment&amp;#39;s stationing is not recognized. &amp;nbsp;See below. &amp;nbsp;The alignment has stationing and it is recognized when I run my corridor. &amp;nbsp;I don&amp;#39;t have this problem with my other alignments. &amp;nbsp;Any ideas of what could be going on?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-discussions-components-files/5922/1881.Capture.JPG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-discussions-components-files/5922/1881.Capture.JPG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Unable to open Tools Dialog box - unknown keyin</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/130739/unable-to-open-tools-dialog-box---unknown-keyin</link><pubDate>Tue, 17 Jan 2017 16:34:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6dfb87d4-6da3-4574-a7db-a8a37987b70b</guid><dc:creator>caddcop</dc:creator><description>&lt;p&gt;Recently I tried using Power InRoads and with it, Descartes to use the Scale-able Terrain Model tools.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I noticed the following messages in the message center: when the toolbox dialog bog failed to open.&lt;/p&gt;
&lt;p&gt;MDL Loader: Unable to load library (DLL or MDL shared library) Bentley.MicroStation.Templates.Support.dll&lt;/p&gt;
&lt;p&gt;Dll Loader: unable to find Bentley.MicroStation.Templates.Support.dll.dll&lt;/p&gt;
&lt;p&gt;MCM unloaded.&lt;/p&gt;
&lt;p&gt;Does anyone know what cause these messages and what I can do to fix this?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>[ORD 2019 R2] Survey Points - Rotate to Linear Segments</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/182867/ord-2019-r2-survey-points---rotate-to-linear-segments</link><pubDate>Mon, 22 Jul 2019 14:26:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9e373cb9-754c-458d-8e85-8b39618938cc</guid><dc:creator>caddcop</dc:creator><description>&lt;p&gt;We are just setting up our ORD Workspace. One setting that I cannot locate in ORD is the ability to rotate a point to the angle of a connecting segment. In particular, we have a GUY code for Guy Wire anchors that in InRoads Survey would rotate to align with the point specified with a JPT code that was a utility pole.&lt;/p&gt;
&lt;p&gt;Can this be accomplished easily or does this require the VBA Macros to function?&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>What If...</title><link>https://communities.bentley.com/achievements/431b6499-29c0-4b75-9a11-0f8ab01b8e9b</link><pubDate>Fri, 14 Aug 2020 15:50:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:10491d76-7114-4a9d-95bf-ef07dcde910a</guid><dc:creator /><description>Share an idea with the community</description></item><item><title>Wanting report of Text Favorites with their dependent Text Styles</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/200039/wanting-report-of-text-favorites-with-their-dependent-text-styles</link><pubDate>Wed, 08 Jul 2020 19:10:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:d016d5c9-b1dc-480a-9ee0-083e3a81860a</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;I want to generate a .dgnlib report listing Text Favorites and their dependent Text Styles.&amp;nbsp; Doesn&amp;#39;t seem possible, any suggestions?&lt;/p&gt;
&lt;p&gt;[If I change the name of a Text Style, will the Text Favorite be dynamically updated to the new name, or is it static?]&lt;/p&gt;
&lt;p&gt;I&amp;#39;m using OpenRoads Designer CE 2020 r.2 upd.8 v.10.08.01.33&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/ORD-Reports.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to recover Tool Settings dialog box</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/199959/how-to-recover-tool-settings-dialog-box</link><pubDate>Tue, 07 Jul 2020 12:34:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a4ccc5d8-2ced-44fc-804a-a9b2f5542369</guid><dc:creator>Paul Turcato</dc:creator><description>&lt;p&gt;In V8i, we would uncheck and check the Tool Settings under Settings.&amp;nbsp; Where do I find this in ORD?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Start Menu has Repeating Shortcuts with Same Name</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/191310/start-menu-has-repeating-shortcuts-with-same-name</link><pubDate>Fri, 17 Jan 2020 21:21:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:14298c6a-41b0-4e19-8c31-3576e7ecd6dc</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;[Using Windows 10, with multiple products loaded:&amp;nbsp; CONNECT Designer, Power InRoads (SS2 &amp;amp;&amp;nbsp;SS4), Power Geopak (SS2 &amp;amp; SS4)... ]&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;The Windows 10 Start Menu has a Bentley folder with many repeating shortcuts of the same name.&amp;nbsp; One can&amp;#39;t know which of my 5 &amp;quot;Set Seed File&amp;quot; shortcuts goes with which product.&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#0000ff;"&gt;&lt;strong&gt;Somebody might want to rethink this for future products.&lt;/strong&gt;&amp;nbsp;&lt;/span&gt; Just sayin&amp;#39; !&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Bentley Configuration Explorer / Switches</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/188624/bentley-configuration-explorer-switches</link><pubDate>Fri, 15 Nov 2019 19:30:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:df4452e7-807a-4a09-aee9-245f8c8caf3b</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;I&amp;#39;m using &lt;strong&gt;Bentley Configuration Explorer 08.11.09.26&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt="ShortcutCreator" src="/resized-image/__size/524x518/__key/communityserver-discussions-components-files/343321/ShortcutCreator.png" /&gt;&lt;/p&gt;
&lt;p&gt;Q1:&amp;nbsp; Which .cfg file is being appended, and when does my specified .cfg file load?&amp;nbsp; Or does my file replace the PowerGeopak.cfg?&amp;nbsp; Please explain the use of -wc switch, is it path only or complete path and filename?&lt;/p&gt;
&lt;p&gt;Q2:&amp;nbsp; When I want to set an additional variable, what would be the syntax?&amp;nbsp; &lt;strong&gt;Add another switch&lt;/strong&gt; -ws&lt;span style="color:#ff0000;"&gt;DEPT-STRUCT&lt;/span&gt;&amp;nbsp;&lt;strong&gt;or append 1st switch&lt;/strong&gt; -ws&lt;span style="color:#3366ff;"&gt;_NSI_AGENCY=TXDOT&lt;/span&gt;&lt;span style="color:#ff0000;"&gt;&lt;strong&gt;;DEPT=STRUCT&lt;/strong&gt;&lt;/span&gt;&amp;nbsp; &amp;nbsp;?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Pat&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Geographic Coordinate System Library</title><link>https://communities.bentley.com/products/geospatial/server/f/geospatial-services-forum/181393/geographic-coordinate-system-library</link><pubDate>Thu, 20 Jun 2019 23:15:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7b0bc983-a3fb-4f81-9717-f3d44ed7b946</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;Using Power InRoads SS4 08.11.09.904&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Regarding the Bentley supplied library of Geographic Coordinate Systems, I was wondering if one system can be verified as correct.&lt;/p&gt;
&lt;p&gt;The system at issue is:&lt;br /&gt;&lt;span style="color:#0000ff;font-size:150%;"&gt;NAD 1983 StatePlane Texas North Central FIPS 4202 Feet&lt;/span&gt;&lt;br /&gt;&lt;span style="color:#0000ff;font-size:150%;"&gt;EPSG: 102738&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;The Maximum Longitude is reported as 96&amp;deg;30&amp;#39;00.0000&amp;quot;W&lt;br /&gt;This does not extend far enough east to cover that band Texas.&lt;br /&gt;Is this value&amp;nbsp;correct?&amp;nbsp; How can it be verified, with ESRI somehow?&lt;/p&gt;
&lt;p&gt;-Pat&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>SS4.904 Power InRoads Cross Sections Cell Control</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/179940/ss4-904-power-inroads-cross-sections-cell-control</link><pubDate>Wed, 22 May 2019 17:29:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:58f3a5b4-68f3-49f0-9f4c-6420e891c802</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-discussions-components-files/5922/XSEC.pdf"&gt;communities.bentley.com/.../XSEC.pdf&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Power InRoads V8i SS4 - 08.11.09.904&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Please&amp;nbsp;refer to&amp;nbsp;the cross sections&amp;nbsp;in the attached PDF.&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;The individual section grid lines did not used to overlap like they are now unitl I tried getting the Existng ROW cell to show up.&amp;nbsp; Starting at 0+75 on the alley, the ROW lines appear at 7.5&amp;#39; left and right.&amp;nbsp; They appear at the wrong scale, and I think the grid size is the reason for the overlap into the next sections (0+80...).&amp;nbsp; The sections do not need to be so tall!&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:inherit;"&gt;&lt;strong&gt;&lt;span style="color:#0000ff;"&gt;I&amp;#39;m having a hard time getting the cell the way I want, and the grids to not overlap.&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt; I viewed a video yesterday that said, don&amp;#39;t worry, they come out fine in the sections.&amp;nbsp; What am I missing?&amp;nbsp; I attempted adjusting the template to use another scale, then another cell.&amp;nbsp; I tried changing the template then the feature definition (not from the library) to use other cell, and also the feature definition to use a Native Style.&lt;br /&gt;Stuck with a mess, and a short fuse on the project!&lt;/p&gt;
&lt;p&gt;-Pat&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Ref:&lt;/p&gt;
&lt;p&gt;&lt;a href="/products/road___site_design/w/road_and_site_design__wiki/7045/corridor-modeling-cross-sections-ss4"&gt;https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/7045/corridor-modeling-cross-sections-ss4&lt;/a&gt;&lt;br /&gt;&lt;a href="/products/road___site_design/w/road_and_site_design__wiki/8500/video-displaying-points-in-cross-sections"&gt;https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/8500/video-displaying-points-in-cross-sections&lt;/a&gt;&lt;br /&gt;&lt;a href="https://youtu.be/UaTOdUANv2g"&gt;https://youtu.be/UaTOdUANv2g&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Critical Sections in SS4 not generated</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/179827/critical-sections-in-ss4-not-generated</link><pubDate>Mon, 20 May 2019 15:57:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:270707d1-3f28-4fff-a586-0a25c3e9380c</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;Power InRoads SS4 (08.11.09.904)&lt;/p&gt;
&lt;p&gt;In the Create Cross Sections dialog, Controls, Critical Sections part... &amp;nbsp;I check off Horizontal and Vertical Cardinal Points because I want sections drawn at those stations.&amp;nbsp; They don&amp;#39;t get created.&lt;/p&gt;
&lt;p&gt;Is this known NOT to work?&amp;nbsp; Trying to determine why I don&amp;#39;t get sections automatically drawn at those stations.&amp;nbsp; Any inputs?&lt;/p&gt;
&lt;p&gt;-Pat&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Civil Cell Reference lines</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/173705/civil-cell-reference-lines</link><pubDate>Tue, 15 Jan 2019 16:19:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cd2693e3-e8d6-41ca-920c-e2f595167ce2</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;&lt;img height="610" src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/5922/PGL_2D00_at_2D00_TC.png" width="784" alt=" " /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;Using Power InRoads V8i (SS4) 08.11.09.904&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Two issues here:&lt;/p&gt;
&lt;p&gt;I&amp;#39;m attempting to place a civil cell I&amp;#39;m developing&amp;nbsp;for a Tee intersection (testing right now) and use the typical two reference lines:&amp;nbsp; Side road centerline and intersecting road edge of pavement.&lt;/p&gt;
&lt;p&gt;1.&amp;nbsp; I had the impression I could click to&amp;nbsp;use a breakline feature&amp;nbsp;from the terrain for the intersecting EOP, but I find I cannot, although It does hold elevation info, so why can I not use it?&lt;/p&gt;
&lt;p&gt;The terrain was created from .dtm file.&amp;nbsp; It happens the EOP line is also along&amp;nbsp;the external boundary.&amp;nbsp; I had to fiddle a little with the terrain template to isolate the EOP (breaklines) to their own level in order to turn off the external, but I got that part, but it did not work.&amp;nbsp; Nor could I use the back of curb for the same purpose.&lt;/p&gt;
&lt;p&gt;I&amp;nbsp;created a HZ feature and profiled it per breakline data, but it means duplicating data.&amp;nbsp; Using this new&amp;nbsp;feature the civil cell placed just fine.&amp;nbsp; Why is the breakline not usable?&amp;nbsp;&amp;nbsp;The terrain resides in a reference file.&lt;/p&gt;
&lt;p&gt;2.&amp;nbsp; Also, my template section uses a null point PGL at the&amp;nbsp;top of curb elevation and has a roof-top crown peaking just beneath, at top of pavement.&amp;nbsp; See graphic attached.&amp;nbsp; Not sure how to build that cell properly, as the PGL controls from&amp;nbsp;&lt;em&gt;above&lt;/em&gt; the surface crown and is not on the pavement surface.&amp;nbsp; Suggestions would be appreciated.&amp;nbsp; What breakline(s) need to get added to pavement surface, and will point control be lost if I need to flatten out the cross-slopes?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Pat&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>PIR Text Editor forgets size &amp;amp; location</title><link>https://communities.bentley.com/products/road___site_design/f/geopak-inroads-mx-openroads-forum/170762/pir-text-editor-forgets-size-location</link><pubDate>Mon, 12 Nov 2018 17:26:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5bfa82a2-5f3e-466d-b317-12173f982ed0</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;I recently installed Power InRoads V8i (SS4) 08.11.09.904 and began using.&lt;/p&gt;
&lt;p&gt;The text editor preference I use is the Word Processor style.&lt;/p&gt;
&lt;p&gt;Upon calling for the editor the 2nd, 3rd, and subsequent times in a session, the Word Processor appears in it&amp;#39;s original size and location, although I have re-sized and moved it from it&amp;#39;s original position every use.&amp;nbsp;&amp;nbsp;My issue is that&amp;nbsp;I must reposition the dialog and open it up much larger (it&amp;#39;s pretty small) &lt;strong&gt;&lt;span style="color:#000000;"&gt;every time&lt;/span&gt;&lt;/strong&gt;.&amp;nbsp; The previous PIR version and MicroStation typically do not behave that way, they behave in the MRU fashion.&lt;/p&gt;
&lt;p&gt;What can I do to change this?&amp;nbsp; Are old workspace preferences /&amp;nbsp;.xml files in use and maybe non-compatible?&amp;nbsp; I don&amp;#39;t want to whack my prefs unless I really need to do it.&lt;/p&gt;
&lt;p&gt;Pat&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Making a MACRO &amp;quot;finish&amp;quot; Cleanly</title><link>https://communities.bentley.com/products/microstation/microstation_printing/f/printing-and-plotting-forum/170198/making-a-macro-finish-cleanly</link><pubDate>Wed, 31 Oct 2018 13:46:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d1873ca-3636-40d6-8b72-218795103f12</guid><dc:creator>John Watts</dc:creator><description>&lt;p&gt;I have created the following macro but I cannot get it to &amp;quot;finish&amp;quot; properly, I always have to R Click the mouse prior to selecting the print icon in the printing dialogue box. I have tried multiple ways to make it &amp;quot;finish&amp;quot; cleaner but haven&amp;#39;t found the right combination. For example, following the instructions from the Help files for Action Strings, I have tried the E, T &amp;amp; K Key Ins and also multiple spaces, slashes (/) and semi-colons (;) all to no avail.&lt;br /&gt;&lt;br /&gt;FIT VIEW EXTENDED 1; PLACE FENCE ACTIVE; / ; PRINT&lt;/p&gt;
&lt;p&gt;Using V8i&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Batch Processing to i-model V8i (SS4)</title><link>https://communities.bentley.com/products/microstation/microstation_printing/f/printing-and-plotting-forum/154851/batch-processing-to-i-model-v8i-ss4</link><pubDate>Thu, 24 May 2018 01:32:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ad2ca4e7-a484-4cf9-b2b7-df397bec0608</guid><dc:creator>Patrick Coyne</dc:creator><description>&lt;p&gt;If&amp;nbsp;somebody is successfully Publishing to I-model using V8i (SS4) &lt;strong&gt;in batch mode&lt;/strong&gt;, I&amp;#39;d like to hear about it the process.&lt;/p&gt;
&lt;p&gt;I just finished&amp;nbsp;some Record Drawings for archival purpose into PDF format and&amp;nbsp;I&amp;#39;d like to Publish the DGNs into a locked&amp;nbsp;.i.dgn format as well.&lt;/p&gt;
&lt;p&gt;Too bad Print Organizer doesn&amp;#39; have a check-box and a settings file selector&amp;nbsp;to do it all at once!&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;-Pat Coyne&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>