Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
renbo tang

renbo tang

Bookmarks
  • Profile
  • Activity
  • Communities
  • Friends
  • Likes
  • Achievements
  • Bookmarks
  • Blog Posts
  • Questions
  • More
  • Cancel
  • Content
  • Applications
  • Groups
  • Followed Members
  • Active Topology Management

    Scott Kampa
    Scott Kampa
    Product(s): WaterGEMS, Hammer, StormCAD, CivilStorm, WaterCAD, SewerCAD, SewerGEMS, PondPack Version(s): CONNECT Edition, V8i, V8 XM Area: Layout and Data Input Overview The purpose of this TechNote is to discuss active topology…
    • over 2 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Assumptions and limitations of tracking air or vapor pockets in HAMMER

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Description What are the assumptions and…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Benchmarking Tool for Connect

    Brahms
    Brahms
    Hello, Does anyone know if there is a benchmarking tool, similar to Cadaylst Benchmark, for MicroStation Connect? If not, perhaps someone has a reliable way to benchmark computer hardware for Connect in another way? Would be extremely helpful…
    • Answered
    • over 3 years ago
    • MicroStation
    • MicroStation Forum
  • Class Editor Parser regular express explanation

    Changsong Ling
    Changsong Ling
    Hello All, I'd understand to know class editor parser regular express, for example, for support name, ^(?<DEVICE_TYPE_CODE>.*)-(?<NUMBER>.*)|(?<NUMBER>.*) It means if input PS-101 in name, it will fill PS in device_type_code, and 101 in number.…
    • Answered
    • over 7 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Forum
  • CONNECT Edition - Custom Configuration Guides

    Yvonne Lohse
    Yvonne Lohse
    Product(s): MicroStation Version(s): 10.06.00.38 Environment: N/A Area: Configuration Subarea: Workspaces The following blogs posts describe the creation of a Custom Configuration for MicroStation…
    • over 4 years ago
    • MicroStation
    • MicroStation Wiki
  • How to bring OpenPlant PID 2D data in 3D OpenPlant Modeler

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.XX.XX.XX Environment: Windows 8.1/10 (64-bit) Area: Consistency Checker Subarea: - Original Author: Swapnil Joshi, Bentley Product…
    • over 1 year ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Create a Managed WorkSet from a custom template using OpenPlant Project Administrator

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Project Administrator Version(s): CONNECT Edition 10.07.00.32 Environment: Windows 8.1/10 (64-bit) Area: Configuration Subarea: - Original Author: Swapnil Joshi,Bentley…
    • over 1 year ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Edit Pipeline Level Naming Rule in Named Expressions

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler V8i Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attribute Subarea: - Original Author: Kestutis Mitkus…
    • over 5 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Import Pipeline list & its Properties from Excel Sheet in OpenPlant Modeler CONNECT

    Rahul Kumar
    Rahul Kumar
    Applies To Product(s): OpenPlant Modeler CONNECT Edition Update 7 Version(s): 10.07.00.32 Environment: Windows 10 (64-bit) Area: Standard Preference Subarea: Import Tag Instances Original Author: Deepak…
    • over 1 year ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Set Pipeline Color by Service in OpenPlant Modeler

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Justinas Lipnickas, Bentley Product Advantage…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • How to Update Pipeline Tag Name or Component Property After any Changes in Schema

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Properties - OpenPlant Modeler Subarea: Original Author: Kestutis…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Modeling Reference - Air Valves

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): HAMMER Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Overview This TechNote explains how the Air Valve…
    • 4 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Named Expressions: Managing Component Symbology in OpenPlant Modeler

    Kestutis Mitkus
    Kestutis Mitkus
    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Jesse Wolfe, Bentley Product Advantage Group…
    • over 6 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Nvidia

    Jose Pinho
    Jose Pinho
    Why do we see Bentley here: (very nice) https://www.nvidia.com/en-us/design-visualization/industries/architecture-engineering-construction/ But no mention in Microstation and Bentley in the catalog: http://www.nvidia.com/content/gpu-applications…
    • over 6 years ago
    • MicroStation
    • MicroStation Forum
  • Preparing an existing model for a transient analysis in HAMMER

    Jesse Dringoli
    Jesse Dringoli
    Product(s): HAMMER Version(s): CONNECT Edition, V8i Area: Layout and Data Input How to: Prepare an existing water model for a transient analysis in Bentley HAMMER. Background The purpose of this article is to…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • To Fix Gasket and Fasteners Issue if not getting Generated on Flanged Joints in OpenPlant Modeler CONNECT Edition

    Ashutosh Patil
    Ashutosh Patil
    Applies To Product(s): OpenPlant Modeler CONNECT Edition Version(s): 10.07.00.32 Update 7 Environment: Windows 8.1/10 (64-bit) Area: Customization/User InterFace Subarea: Original Author: Ashutosh…
    • over 3 years ago
    • OpenPlant | AutoPLANT
    • OpenPlant | AutoPLANT Wiki
  • Transient pressure worse with air valve added

    Jesse Dringoli
    Jesse Dringoli
    Product(s): HAMMER Version(s): V8i, CONNECT Edition Area: Modeling Problem Why are my maximum transient pressures higher when using an air valve, compared to not using an air valve? Why does using an air valve sometimes make…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Understanding length/wave speed adjustments and their impact on results

    Scott Kampa
    Scott Kampa
    Applies To Product(s): HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem When computing a transient simulation, the following error…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • User notification: The period between path histories has been increased by a factor of X to limit the number of path records to Y.

    Scott Kampa
    Scott Kampa
    Applies To Product(s): HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Original Author: Jesse Dringoli, Bentley Technical Support Group Problem Why do I get the following user notification…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • What configuration changes have been made in MicroStation CONNECT Edition?

    Yvonne Lohse
    Yvonne Lohse
    Product: MicroStation Version: 10.00.00.25 Environment: N\A Area: Configuration Subarea: General Background This is a basic overview of what configuration changes have been made within MicroStation…
    • over 5 years ago
    • MicroStation
    • MicroStation Wiki
<>
Communities
  • Home
  • Getting Started
  • Community Central
  • Products
  • Support
  • Secure File Upload
  • Feedback
Support and Services
  • Home
  • Product Support
  • Downloads
  • Subscription Services Portal
Training and Learning
  • Home
  • About Bentley Institute
  • My Learning History
  • Reference Books
Social Media
  •    LinkedIn
  •    Facebook
  •    Twitter
  •    YouTube
  •    RSS Feed
  •    Email

© 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies