  • RE: Special Ditch Criteria File Not Running

    Brandon H.
    Brandon H.

    Tried this and it turned out that it didn't like that I had copied the lines "Special Ditch Begin/", etc.

    Lesson learned: Just copy the if statement.

    Thanks

    • over 1 year ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: Mistake in AASHTO-2011_metric superelevation XML file

    Manuel Soriano
    Manuel Soriano

    Hola Nico, el valor seria 15/.3*1.6*1.6=128? Yo recuerdo de mis tiempos de docente que la velocidad especifica en curva se definia como V^2=127*R*(p+f)

    • over 2 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: OpenRoads Conceptstation - Import XML won't let you choose what template to use

    Simon Normand
    Simon Normand

    Hi Jeremie,

    We added these options for ALG in our Update6 release. For our next update, we'll be adding these same capabilities for LandXML import.

    thanks,

    Simon

    • over 3 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: OpenRoads Profile View Opaque

    caddcop
    caddcop

    Is Transparency disabled? Also, if you use the Copy View command, you can copy all settings from an un-screwed up view to a screwed up view. Follow that with a save settings and you are good to go.

    • over 3 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: Conduit parameters are not applied to importet conduits.

    Robert Garrett
    Robert Garrett

    Jan:

    A couple of notes:

    First, when extracting utilities from graphics the minimum bending radius does not apply.  The extract graphics command was designed to make a utility model which matches the graphics,  with the underlying assumption that the graphics…

    • over 3 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: SUDA keeps changing the Width and Length of Structures, Drop Inlets and Manholes whenever I compute

    viet
    viet

    I have Bentley Geopak v8i SS4 08.11.09.878, and OpenRoads v8i SS4 installed

    • over 3 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: Plotting Cross Sections

    Dawn Michel
    Dawn Michel

    I had my design stage set to "Final-mesh".  Once I set it back to "final" everything worked fine.  Thanks for the help.

    • over 3 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: Not able to change design stage...it just hangs until it crashes GEOPAK SS4 (08.11.09.851)

    Chuck K.
    Chuck K.
    Well, I accidentally turned one of my point controls to false from true and it took a while to update but it is now miraculously design stage 3?!?!!? When I toggled it back to true the PC didn't show up so I had to delete that PC entry and re input it…
    • over 4 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • OpenRoads ViewSet.mvba - 3d Vertical Exaggeration tool "ExaggerateZForAttachment"

    Michael-Lane
    Michael-Lane

    One aspect of using Bentley OpenRoads software that has taken some getting used to is the ability to quickly view 3d model data with exaggerated z scale.  Luckily, I came across a macro in the Benltey installed workspace that addresses this task.  I thought…

    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: Template Vs. Criteria Creation

    Katie Johnson
    Katie Johnson
    Chris,
    I've done a lot of template development work after doing several years of custom criteria development. There isn't an exact equivalent to the if/then criteria logic, but you can use end conditions quite effectively to choose among options. The…
    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: .NET Framework error when I mouse over a newly opened file with OR cross sections

    Michael-Lane
    Michael-Lane
    Update: Bentley support has been able to reproduce this on their end and have filed defect #197796:Crash in Dynamic Cross Sections with 2 Application Windows.
    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
    • Christiaan Post
  • RE: .NET Framework error before any elements are rendered

    Derek Schmidt
    Derek Schmidt
    Ugh. Right now everything seems to be working even when I use the UPF that I had claimed to be faulty. When I find that this error is coming up again I'll try creating a new file at that point and see how that works for me.
    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • RE: MicroStation design history reporting "Permission denied"

    Derek Schmidt
    Derek Schmidt

    To clarify the problem, when I'm using geopak.3.0.cfg, nothing about history works (from what obvious buttons are available--or not). When I have it turned off, I have access to what might be all history--even changes auto-committed while I was running…

    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
  • .NET Framework error when I mouse over a newly opened file with OR cross sections

    Derek Schmidt
    Derek Schmidt

    This error had already been mentioned in another thread, but I'm creating a new thread because the mention of this error had been a departure from the original post in that thread. With the help and gracious patience of Phil Chuinard, Jan Slegr, and…

    • Answered
    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
    • Ross Brown
  • RE: cross section of tin in survey field book

    caddcop
    caddcop
    This situation, is one reason we need to be able to display components in a profile, just like in a cross section.
    • over 5 years ago
    • OpenRoads | OpenSite
    • OpenRoads | OpenSite Forum
>
Communities
  • Home
  • Getting Started
  • Community Central
  • Products
  • Support
  • Secure File Upload
  • Feedback
Support and Services
  • Home
  • Product Support
  • Downloads
  • Subscription Services Portal
Training and Learning
  • Home
  • About Bentley Institute
  • My Learning History
  • Reference Books
Social Media
  •    LinkedIn
  •    Facebook
  •    Twitter
  •    YouTube
  •    RSS Feed
  •    Email

© 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies