Re: Lift station - Defining parameters
mtaylor
Thanks for the help Tom. It's the second case. We were using elevations in the control set up, and not the "depths", so our "pump on" level was set about 1000' too high. I can't say we have it all working now, but the system is cycling.
over 15 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
RE: SewerGEMS - Lifting Pump station
Jesse Dringoli
Hello Rossouw, I'm visualizing that your system looks like one of below sketches: (A) Short pressure pipe discharging into gravity conduit that exits manhole (B) Pressure pipe rises to the top of the manhole then continues downstream as a pressure…
over 8 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
RE: How to use wet well & pump combination in SewerGEMS?
Jesse Dringoli
Rohit, Can you tell us a bit more about why you are wanting to directly pass the wetwell inflow into the downstream receiving gravity manhole? Are you trying to assume an "ideal pump" for preliminary design, before the pump is sized? Which numerical…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum