Pump Startup - VSP Type - Can you configure a pump to have multiple VSP types?
Jesse Ellis
Is it possible to configure a pump to have multiple VSP types? Ideally, we want to use the [Pattern Based] VSP Type up to a point and then switch to [Fixed Flow] VSP Type. If not, is there any workaround for the following real-life scenario? We…
Answered
9 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
RE: Modeling Swing Check Valves in HAMMER
Yashodhan Joshi
Hello Jesse, From the relative closure pattern it seems you are modeling a two stage check valve closure (modeled as TCV with an operational relative closure pattern). Jesse Ellis said: Can I model the Check valve as a ball valve that is 100% open…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
RE: Volumetric data on a time step by step basis for Air Valves in HAMMER
Jesse Dringoli
To add to Sushma's reply - when entering a value in the Report Period property of an air valve and looking at the table of extended results at the bottom of the Transient Detailed Report, the information displayed there (air flow rate, air volume, pressure…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
RE: Volumetric data on a time step by step basis for Air Valves in HAMMER
Sushma Choure
Hello Jesse, Could you please elaborate your query, the formula you are referring is mentioned under air flow rate calculation and what you are looking for is air volume, which is not reported currently in the tabular format which could be readily available…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum