<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>cswnow's Communities Activities</title><link>https://communities.bentley.com/members/e01c6561_2d00_6527_2d00_4c4d_2d00_8816_2d00_2039c255274e</link><description>Recent activity for people in cswnow's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Reference clipped elements is printing</title><link>https://communities.bentley.com/products/microstation/microstation_printing/f/printing-and-plotting-forum/176794/reference-clipped-elements-is-printing</link><pubDate>Mon, 18 Mar 2019 20:12:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:93a0b894-359e-4e0a-a7a9-5b16c2424f0e</guid><dc:creator>Lucilia</dc:creator><description>&lt;p&gt;I have files where references are clipped using linear element.&amp;nbsp; It appears fine on screen and when creating PDFs, using print organizer, a hidden portion of the clipped reference is printing. I&amp;#39;m using Microstation V8i SS4 08.11.09.832 version.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/19568/pastedimage1552939820897v5.png" /&gt;&lt;/p&gt;
&lt;p&gt;This how it&amp;#39;s showing on screen&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/19568/pastedimage1552939865100v6.png" /&gt;&lt;/p&gt;
&lt;p&gt;This is how it&amp;#39;s printing&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can not create custom Detailing symbols in Connect</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/170657/can-not-create-custom-detailing-symbols-in-connect</link><pubDate>Fri, 09 Nov 2018 22:09:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f3a4f7e7-0f5a-4443-8725-5e2719d84ab7</guid><dc:creator>cswnow</dc:creator><description>&lt;p&gt;Detailing symbols are working fine in V8i . Trying to get them to work in Connect.&amp;nbsp; When I go to create them I keep getting and error message&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-discussions-components-files/343321/Capture44.JPG" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;&lt;br /&gt;The pull down to attach the cell under the Tail wing&amp;nbsp; populates with nothing from my cell library.&lt;br /&gt;&lt;br /&gt;I have these set in my standards.cfg file&lt;br /&gt;&lt;br /&gt;MS_DETAILINGSYMBOLS_CELLLIST = $(_USTN_ORGANIZATION)dgnlib/DrawComp/*.cel&lt;br /&gt;MS_DGNLIBLIST_DETAILINGSYMBOLSTYLES = $(_USTN_ORGANIZATION)dgnlib/DrawComp/WWE_DETAILING_SYMBOLS.dgnlib&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ribbon Customization and Tabs</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/167194/ribbon-customization-and-tabs</link><pubDate>Tue, 28 Aug 2018 19:22:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:84a684a0-45ad-4f46-beaf-128a0b0400d2</guid><dc:creator>cswnow</dc:creator><description>&lt;p&gt;I wanted to add a few more tabs to the &lt;strong&gt;Drawing&lt;/strong&gt; workflow and it was only allowing me to add one.&lt;br /&gt;&lt;br /&gt;I created another workflow and was allowed to add more tabs with no problem.&lt;br /&gt;&lt;br /&gt;My question is:&lt;br /&gt;&lt;br /&gt;Is there a maximum number of tabs you can have under each workflow.&amp;nbsp; It seems to be 12.&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;br /&gt;&lt;br /&gt;Craig&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Openplant 3D file translated to AutoCAD 3D. The pipes disappear when the operator flat files the file.</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/145499/openplant-3d-file-translated-to-autocad-3d-the-pipes-disappear-when-the-operator-flat-files-the-file</link><pubDate>Wed, 10 Jan 2018 23:07:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:02200af7-0e3f-4d47-9c33-bdecc652ea8a</guid><dc:creator>cswnow</dc:creator><description>&lt;p&gt;I am exporting a OpenPlant model to AutoCAD.&amp;nbsp; When the AutoCAD operator opens it up and flat files it the pipes disappear while the fittings remain.&amp;nbsp; I am not an AutoCAD operator.&amp;nbsp; Is there a setting I can set when I translate it to AutoCAD.&amp;nbsp; I merge all the reference files into one file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>What happened to TFREMOVE?  What can I do.</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/139853/what-happened-to-tfremove-what-can-i-do</link><pubDate>Wed, 16 Aug 2017 22:26:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:af1347a3-760e-4d9a-94f0-ef6602234221</guid><dc:creator>cswnow</dc:creator><description>&lt;p&gt;We haven&amp;#39;t used Trifroma in 5 or 6 years. &amp;nbsp;I have some old model files that I get the standard&amp;nbsp;&amp;quot;Trifroma has intentionally restricted the changes to this element&amp;quot; &amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;br /&gt;In the past&amp;nbsp;we have been able to use the TFREMOVE command in V8i and it would remove the Triforma restrictions. &amp;nbsp;Not the case anymore. &amp;nbsp;&lt;/p&gt;
&lt;p&gt;We really don&amp;#39;t want to redraft them, and you can&amp;#39;t go download the older versions anymore.&lt;/p&gt;
&lt;p&gt;Yes you can drop them, with complex and shared cells check which allows you to move and copy them, but no other manipulation is allowed&lt;/p&gt;
&lt;p&gt;Any help would be appreciated&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Wed, 16 Aug 2017 00:25:53 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2124edb5-0293-400f-aef2-96a746608e4b</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>Redirect Connect to our server</title><link>https://communities.bentley.com/products/administration/f/product-administration-forum/125888/redirect-connect-to-our-server</link><pubDate>Thu, 08 Sep 2016 20:26:55 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:94f7dbfa-8a62-4869-8be0-110ee58df54c</guid><dc:creator>cswnow</dc:creator><description>&lt;p&gt;I think I got Microstation Connect to redirect to my server. &amp;nbsp;I modified the&amp;nbsp;C:\ProgramData\Bentley\CONNECT Edition\Configuration\WorkSpaceSetup.cfg file to point to&lt;/p&gt;
&lt;p&gt;my server which contains the file structure:&lt;br /&gt;K:\WWE Configuration\&lt;br /&gt;K:\WWE Configuration\Organization\&lt;br /&gt;K:\WWE Configuration\WorkSpaces\&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;It all seems to be working fine. &amp;nbsp;Just curious why I would not put the WorkSpaceSetup.cfg file on my server under&amp;nbsp;K:\WWE Configuration\ &amp;nbsp; &amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;and each local machine just put another redirect file, ie &amp;nbsp;ServerRedirect.cfg &amp;nbsp;that contained the simple line:&amp;nbsp;%include K:/WWE Configuration/*.cfg&lt;/p&gt;
&lt;p&gt;I tried this second method and it didn&amp;#39;t work. It just reverted back to the local area when I tried to create a new WorkSpace. &amp;nbsp;Is the mslocal or msdir stopping this?&lt;br /&gt;Putting a small .cfg file on each computer is the simple way we did it with V8i and it worked perfectly. &amp;nbsp; &amp;nbsp; I have no problem putting the WorkSpaceSetup.cfg on each machine if that what it takes. &amp;nbsp;&lt;/p&gt;
&lt;p&gt;We are just starting to migrate over and I want to get this working. &amp;nbsp; Any help would be appreciated.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How do you import a .obj file into MicroStation.</title><link>https://communities.bentley.com/products/microstation/f/microstation-forum/107104/how-do-you-import-a-obj-file-into-microstation</link><pubDate>Wed, 13 May 2015 16:27:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a93fa9b7-2031-43bc-9707-aa10336fa527</guid><dc:creator>cswnow</dc:creator><description>&lt;p&gt;How do you import a .obj file into MicroStation. &amp;nbsp;Using SS2. &amp;nbsp; Do I have to convert it first? I have a bunch of .jpg and a .mtl file in the same directory as the .obj file. &amp;nbsp;I see that others have done it, but I don&amp;#39;t see anything under the import feature. &amp;nbsp;Thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>