<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Abhijeet Shinde's Communities Activities</title><link>https://communities.bentley.com/members/e8410660_2d00_6c71_2d00_421b_2d00_a4cc_2d00_1187fb048d48</link><description>Recent activity for people in Abhijeet Shinde's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>AutoPLANT Modeler CONNECT Edition - Uninstallation Procedure</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58984/autoplant-modeler-connect-edition---uninstallation-procedure</link><pubDate>Mon, 28 Mar 2022 15:20:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f399fb33-2adb-4a9e-8af0-ec5054e538ed</guid><dc:creator>Joseph Gelacio</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Uninstallation&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;On rare occasions, the uninstall process available for the AutoPLANT suite can become somehow corrupted, preventing it from properly removing the associated files, binaries, and registry entries.&amp;nbsp; On these rare occasions, it can become necessary to manually uninstall the AutoPLANT product.&amp;nbsp; The steps below detail this process&lt;/p&gt;
&lt;p&gt;**It should be noted that only qualified personnel with experience in registry edits should perform the steps below**&lt;/p&gt;
&lt;h1&gt;Steps to Follow&lt;/h1&gt;
&lt;p&gt;1.Kill the BPCOM32 process from the task manager and uninstall the&amp;nbsp;the &amp;quot;iModel connector for AutoPLANT&amp;quot; otherwise it will not allow the uninstall of AutoPlant.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;2.Go to Control Panel and uninstall the AutoPLANT Modeler CONNECT Update 2&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/6478316425.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/5402252.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/478171447.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;3.Before deleting the following folders make sure your projects are saved and backed up somewhere safe.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;4.Delete the Plant V8i folder from the below application directory.&lt;/p&gt;
&lt;p&gt;C:\ProgramData\Bentley&amp;nbsp;&lt;/p&gt;
&lt;p&gt;C:\Program Files (x86)\Bentley&lt;/p&gt;
&lt;p&gt;5.After uninstalling the AutoPLANT Modeler CE, it is recommended to check the registry entries for Plant V8i folder.&lt;/p&gt;
&lt;p&gt;6.Delete plant V8i folder from registry editor&lt;/p&gt;
&lt;p&gt;Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Bentley\Plant V8i&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/72377557.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;Computer\HKEY_CURRENT_USER\SOFTWARE\Bentley\Plant V8i&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/7152153167.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;7.Delete all the shortcuts for AutoPLANT&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;8.Restart the Machine&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/42540/autoplant-modeler-connect-edition---installation-procedure"&gt;communities.bentley.com/.../autoplant-modeler-connect-edition---installation-procedure&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Invalid Pointer Error While Generating Report in AutoPLANT Modeler CONNECT Edition</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/60572/invalid-pointer-error-while-generating-report-in-autoplant-modeler-connect-edition</link><pubDate>Thu, 02 Jun 2022 13:28:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:58b6ae9e-8773-42ab-b8b9-8d0a703d6674</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Settings\Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;In AutoPLANT Modeler while generating report user may face below Error.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/882240.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;When user create the circular references of several drawing files in XREF Manager in AutoPLANT Modeler then this error message pops up during the generation of report.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/377512583.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;This Wiki article explains the steps to resolve this issue&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;1.Open the AutoPLANT Modeler session&lt;/p&gt;
&lt;p&gt;2.Open XREF Manager and check for circular references attached in the drawing file.&lt;/p&gt;
&lt;p&gt;3.Delete the created circular references in the drawing file.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46885/autoplant-modeler-connect-edition"&gt;communities.bentley.com/.../autoplant-modeler-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to add Spec Criteria in Project Isometrics in AutoPLANT Modeler CONNECT Edition</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/60570/how-to-add-spec-criteria-in-project-isometrics-in-autoplant-modeler-connect-edition</link><pubDate>Thu, 02 Jun 2022 13:14:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e243c815-b55e-4377-a612-0c7c68c8a397</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AP_OPIM&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Settings\Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;&lt;span style="background:white;font-weight:bold;"&gt;How to add SPEC Criteria in Project Iso so as user can use Spec Criteria for Project Iso&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;User requirement to add Spec as default Break Criteria in the Project Iso.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/182260746327.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;1.Navigate to the OpenPlant folder of the specified Project where Spec need to be added in the given Isostyle.&lt;/p&gt;
&lt;p&gt;C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant&lt;/p&gt;
&lt;p&gt;2.Open OPIM.ini file and add Spec Criteria manually as shown below.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/023775.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/45082186.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;3.Once the above changes are made generate the Isometrics and verify that Spec Criteria is coming in Isometrics dropdown Window.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/26464426.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How To Create Custom Style in AutoPLANT Modeler and OpenPlant Isometrics Manager CONNECT Edition .</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/60569/how-to-create-custom-style-in-autoplant-modeler-and-openplant-isometrics-manager-connect-edition</link><pubDate>Thu, 02 Jun 2022 13:01:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:009abce9-6f41-4e5f-8daf-d9c81f4a3b0c</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AP_OPIM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Settings\Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;In OpenPlant Isometrics Manager CONNECT Edition, users can create own desired custom style using default style as templates and change attributes and set the settings as desired.&lt;/p&gt;
&lt;p&gt;Below wiki is a simple walk through on how to create custom style in isometric manager. This wiki article has been explained in the context of AutoPLANT Modeler and OpenPlant Isometrics Manager.&lt;/p&gt;
&lt;h1&gt;&lt;/h1&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;&lt;span style="background:white;"&gt;1.Open the Project Administrator&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background:white;"&gt;2.Launch the Isometric Configuration setting&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background:white;"&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/08511655.jpg" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="background:white;"&gt;3.&lt;/span&gt;In configuration window click on New button to add a new style for the project.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/688466.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;4.In Add Style box, select the Base Style as desired and give Style Name:&amp;nbsp;&lt;strong&gt;Custom_Style&lt;/strong&gt;&amp;nbsp;which means it has all the settings which are set for IFC style template and click OK. We can also change these attributes and click on&amp;nbsp;&lt;strong&gt;Save option&lt;/strong&gt;&amp;nbsp;with our own settings.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/204834.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;5.Verify result from drop down menu. This style can be helpful for users in creating Custom Settings for isometric style.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x520/__key/communityserver-wikis-components-files/00-00-00-00-43/450826011.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Error ‘macro syntax error’ appears while generating Isometric Drawing in OpenPlant Isometrics Manager CE.</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/59012/error-macro-syntax-error-appears-while-generating-isometric-drawing-in-openplant-isometrics-manager-ce</link><pubDate>Tue, 29 Mar 2022 14:46:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0df9ce05-7ae2-4ecd-95aa-358394c396d4</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AP_OPIM &amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.XX.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Error, Logs, Messages, Crashes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;While working with AutoPLANT Modeler and OpenPlant Isometric Manager CE, user may below error message while generating the isometrics drawing. This wiki article explains the steps to resolve this issue.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/865215446.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;This errors generally appears when user creates the incorrect the Spool numbering sequence for welds, pipes, etc in the style.cfg file.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Comment out the highlighted variable from style.cfg file as shown in below snapshot&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/32670835.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to Generate the PCF File in AutoPLANT Modeler CONNECT Edition</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58980/how-to-generate-the-pcf-file-in-autoplant-modeler-connect-edition</link><pubDate>Mon, 28 Mar 2022 13:13:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:be2bb22b-9e57-4462-97a2-aeeb411ef84d</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AP_OPIM CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Settings\Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;In OpenPlant Isometric Manager, there is requirement to generate the PCF file for other systems software. PCF file has all required attribute inside the file. While generating an isometric drawing from the model, a Piping Component file (PCF) is automatically created. PCF file can be exported if required for the Stress Engineering. This wiki article explains the steps on how to generate PCF file in AutoPLANT Modeler. This wiki article has been described in context with the AutoPLANT Modeler and OpenPlant Isometric Manager CE&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;1.Open the Project Administrator&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;2.Launch the Isometric Configuration setting&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/60321758.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;3.Select the Isometric style, go to Output Format and select the PCF file option.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/84142828821.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;4.Generate the Isometric drawing for the drawing file.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;5.PCF file will generate in the below directory&lt;/p&gt;
&lt;p&gt;C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Isometrics\Styles\IFC\PCF&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/6463830.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Error ‘Bentley Document Manager has stopped working appears while opening drawing through Document Manager in AutoPLANT Modeler</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58979/error-bentley-document-manager-has-stopped-working-appears-while-opening-drawing-through-document-manager-in-autoplant-modeler</link><pubDate>Mon, 28 Mar 2022 12:22:40 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:62ff737d-cace-4acb-b72a-d6149c61d242</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.XX.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Settings\Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;While working with AutoPLANT Modeler CE, user may below error message while opening drawing file through Bentley Document Manager. This wiki article explains the steps to resolve this issue.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/178707012.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;This errors generally appears while opening while opening drawing through Bentley Document Manager. This issue is caused when user installs the AutoPLANT Modeler CE in Windows 7 machine. AutoPLANT Modeler CE is not supported with Windows 7 environment.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;Install the AutoPLANT Modeler CE with Windows 10 Machine&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Error ‘’Could not Find Acceptable License, Application will Run in Limited Mode’’ Appears when tried to Open the I Model Connector in a Separate Machine.</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58941/error-could-not-find-acceptable-license-application-will-run-in-limited-mode-appears-when-tried-to-open-the-i-model-connector-in-a-separate-machine</link><pubDate>Thu, 24 Mar 2022 15:44:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:fbb9c57b-e9f6-4ea9-8f1a-d5f163239184</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Error, Logs, Crashes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;In AutoPLANT Modeler CE, when user installs the I Model Connector in a separate machine, sometimes user may below error while tried to open the I Model Connector.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;On a separate machine, noticed that Connection was not installed in the machine. this issue happens due to license activation issue. This wiki article explains the steps on how to resolve this issue.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/786867285487.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;1.Install Connection client&lt;/p&gt;
&lt;p&gt;2.Logged in with user detail&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Error &amp;#39;Files Not Found&amp;#39;  Appears when tried to Open the Drawing File from Document Manager</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58940/error-files-not-found-appears-when-tried-to-open-the-drawing-file-from-document-manager</link><pubDate>Thu, 24 Mar 2022 14:35:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:77ad5f81-200a-476b-b464-fe68c43ae6e2</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Error, Logs, Crashes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;In AutoPLANT Modeler CE, user may face below error message when trying to open the drawing file from the Document Manager. This wiki article explains the steps on how to resolve this issue.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/726421.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;This error message generally happens when the user copies the drawing files from another project and pastes them into the drawing file location which is the not correct method. Sometimes this can happen due to a corrupted drawing file.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;1.Take the backup of the drawing and store it in another location.&lt;/p&gt;
&lt;p&gt;2.Delete the drawing file with the help of the Relationship manager.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/138024.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;3.Import the same drawing file with the help of the Relationship Manager.&lt;/p&gt;
&lt;p&gt;&lt;em&gt;(Note: Refer to the attached wiki article on how to import the drawing file)&lt;/em&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/43589/how-to-import-a-drawing-file-from-one-project-to-another-project-using-relationship-manager"&gt;communities.bentley.com/.../how-to-import-a-drawing-file-from-one-project-to-another-project-using-relationship-manager&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to Add Coordinate Information with the Comment in the Isometric Drawing Using OPIM</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58938/how-to-add-coordinate-information-with-the-comment-in-the-isometric-drawing-using-opim</link><pubDate>Thu, 24 Mar 2022 13:47:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:db2f74e3-6f92-47c2-993c-eb82e9905b7d</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AP_OPIM&amp;nbsp;CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.XX.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Settings\Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;In Isometric drawing, there is a requirement to show coordinates with the comment. Generally, it shows the coordinates points on the flange and other components. By default, it does not show the coordinates with the comment. This wiki article explains the steps on how to add coordinates information with the comment. This wiki article has been described in context with the AutoPLANT Modeler and OpenPlant Isometric Manager CE.&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;p&gt;1.While adding Comment mention the &lt;strong&gt;$(COORD)&lt;/strong&gt; variable, as shown in below snapshot.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/765364.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/82100312.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;2.Generate the isometric drawing.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;3.Coordinates will appear at the comment.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/1171777.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>OPIM gets crash when tried to generate the isometric drawing from OPIM Out session</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58803/opim-gets-crash-when-tried-to-generate-the-isometric-drawing-from-opim-out-session</link><pubDate>Thu, 17 Mar 2022 14:08:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a3594937-5590-4312-8770-39bd72316f86</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AP_OPIM CE&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Error, Logs, Messages, Crashes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&amp;nbsp;&lt;/h1&gt;
&lt;p&gt;While working with AutoPLANT Modeler CE &amp;amp; OpenPlant Isometric Manager sometimes OPIM gets crash when tried to generate the isometric drawing from out session. This wiki article explains the steps to resolve this issue.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;This issue generally happens due to different regional setting. After investigating the log file, noticed that the wrong co-ordinates is reason behind this crash. OPIM process wrong coordinates while processing AutoPLANT Co-ordinates. OPIM Processing wrong coordinates because of the different regional setting.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/480x480/__key/communityserver-wikis-components-files/00-00-00-00-43/4722.OPIM.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;1.Open the regional settings&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;2.Set the regional settings as per below snapshot.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/1072.regional-setting.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;3.Generate the isometric drawing&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Retrieving the COM class factory for Component with CLSID Error Appears when tried to publish I model in AutoPLANT Modeler CE</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58775/retrieving-the-com-class-factory-for-component-with-clsid-error-appears-when-tried-to-publish-i-model-in-autoplant-modeler-ce</link><pubDate>Wed, 16 Mar 2022 14:51:33 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:46e485d0-c0d3-4c97-85a6-2712027b8157</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT I Model Composer CE&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Error, Logs, Messages, Crashes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;While working with AutoPLANT I Model Composer, sometimes user may face below error message while publishing the I Model. This wiki article explains the steps to resolve this issue.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/errr.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;One of the possible reason behind this error message can be installation issue. This error message generally happens if the user. when user installs the AutoPLANT I model composer before the installation of AutoPLANT Modeler. AutoPLANT I Model Composer can be install after installation of AutoPLANT Modeler.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;1.Kill the BPCom32 process from the task manager&lt;/p&gt;
&lt;p&gt;2.Uninstall the AutoPLANT I Model Composer CE&lt;/p&gt;
&lt;p&gt;3.Install the AutoPLANT I Model Composer CE&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Error Occurs While Unpackaging the Project in AutoPLANT Modeler CE</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/58502/error-occurs-while-unpackaging-the-project-in-autoplant-modeler-ce</link><pubDate>Fri, 25 Feb 2022 19:05:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a4381d5c-58b5-410d-a14f-d3421106b889</guid><dc:creator>Abhijeet Shinde</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Applies To&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Product(s):&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Version(s):&lt;/td&gt;
&lt;td&gt;10.00.XX.XX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Environment:&lt;/td&gt;
&lt;td&gt;Windows 10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Area:&lt;/td&gt;
&lt;td&gt;Error, Logs, Messages, Crashes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Subarea:&amp;nbsp;&lt;/td&gt;
&lt;td&gt;Project Packager&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Original Author:&lt;/td&gt;
&lt;td&gt;Abhijeet Shinde, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Project packager enables you to package a complete project into a single ZIP file. By stepping through the project packager wizard, a project and its associated databases are converted into a common structure that allows them to be unpackaged using the specified database provider type as the resulting format.&lt;/p&gt;
&lt;p&gt;After creating project package through Project Packager, some times user may below error while unpackaging this project in other machine.&lt;/p&gt;
&lt;p&gt;This wiki article explains the steps to resolve this issue.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/511700513.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;This issue happens when user create the AutoPLANT Project package with SQL database and tries to unpackage the same project in other machine with Access database. While investigating log file noticed that problem arise because of the field length value. It was mentioned beyond the limit in SQL database. Ideal Varchar limit is 255 for Access database&lt;/p&gt;
&lt;p&gt;Check the error mentioned in below log file. Check the log file at the below directory.&lt;/p&gt;
&lt;p&gt;C:\ProgramData\Bentley\Plant V8i\Packager\LogFiles&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/705737503.jpg" /&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;1.Open the SQL database&lt;/p&gt;
&lt;p&gt;2.Check the table mentioned in the log file.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/520x480/__key/communityserver-wikis-components-files/00-00-00-00-43/107664.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;3.Modify the Var char value for the table. It should be upto 255 length for Access database.&lt;/p&gt;
&lt;p&gt;4.After correcting &amp;nbsp;all the field, create the Project package and unpackaging work properly.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/46896/autoplant---openplant-isometrics-manager-connect-edition"&gt;communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;span style="font-size:150%;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Still a Problem?&lt;/h1&gt;
&lt;p&gt;If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. &amp;nbsp;Please include a list of all relevant details to get in depth analysis for a solution or workaround.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>AutoPLANT Modeler CONNECT /V8i Object Enabler for AutoCAD</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/32642/autoplant-modeler-connect-v8i-object-enabler-for-autocad</link><pubDate>Tue, 27 Feb 2018 22:18:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f6738cfa-3224-4029-a49f-9139a45eec20</guid><dc:creator>Rahul Kumar</dc:creator><description>&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:600px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;b&gt;Applies To;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler V8i /CONNECT Object Enabler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SS6 (08.11.11.135) |&amp;nbsp;SS7 (08.11.12.226) |&amp;nbsp;SS8 (08.11.13.129/211/08.11.14.01)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler CONNECT Edition[FAQ]&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AutoPLANT Modeler V8i/CONNECT Object Enabler for AutoCAD&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Overview&lt;/h3&gt;
&lt;p&gt;AutoPLANT Object Enabler is an AutoCAD plug-in that allows users who do not have AutoPLANT installed to view AutoPLANT objects in AutoCAD.&lt;/p&gt;
&lt;p&gt;All AutoPLANT Object&amp;nbsp;Enablers can be found in&amp;nbsp;Bentley Software&amp;nbsp;Fulfilment center.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2016_2D00_10_2D00_04_5F00_09_2D00_03_2D00_25.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;But there are some situations when users don&amp;#39;t have any&amp;nbsp;Bentley software, its support or possibility to download it from Bentley Software fulfilment center&amp;nbsp;and have the need very regularly to interface with drawings/models, that are created using the Bentley software.&lt;/p&gt;
&lt;h3&gt;Solution&lt;/h3&gt;
&lt;p&gt;In order to help all our users, download AutoPLANT Object Enablers for required AutoPLANT version, we have created this wiki article with Links without expiration date:&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Important Note:&lt;/strong&gt; &lt;em&gt;It is advisable to remove the previous installer and then do fresh installation to avoid any further problem. Also Keep one installer at a time in a machine.&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-ObjectEnablers-CONNECT-Update-3-x64_5F00_10.03.00.007.zip"&gt;communities.bentley.com/.../AutoPLANT-ObjectEnablers-CONNECT-Update-3-x64_5F00_10.03.00.007.zip&lt;/a&gt;&amp;nbsp;- For AutoCAD 2021 &amp;amp; 2022&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " border="0" height="374" src="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/abc.jpg" width="982" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-CONNECT-Update-2-x-64-apoe10020001en_5F00_updt2.zip"&gt;AutoPLANT-Object-Enabler-CONNECT-Update-2-x-64-apoe10020001en_5F00_updt2.zip&amp;nbsp;&lt;/a&gt;&lt;span&gt;- for Auto&lt;/span&gt;&lt;span&gt;CAD 2020&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-CONNECT-Edition-x64-10.00.00.28.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-CONNECT-Edition-x64-10.00.00.28.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2019/2017&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.15.01.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.15.01.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2018&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.14.124.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.14.124.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2017/2016&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.13.211.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.13.211.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2016&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.13.129.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS8_2900_-08.11.13.129.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2016&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS7_2900_-08.11.12.226.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS7_2900_-08.11.12.226.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2015&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS6_2900_-08.11.11.135.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS6_2900_-08.11.11.135.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2014&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS5_2900_-08.11.10.182.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS5_2900_-08.11.10.182.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2013&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS4_2900_-08.11.09.140en.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS4_2900_-08.11.09.140en.exe.zip&lt;/a&gt;&amp;nbsp;- for AutoCAD 2012&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-x64-_2800_SS3_2900_-08.11.08.123en.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-x64-_2800_SS3_2900_-08.11.08.123en.exe.zip&lt;/a&gt;&amp;nbsp;-&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-_2800_SS2_2900_-08.11.07.60en.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-_2800_SS2_2900_-08.11.07.60en.exe.zip&lt;/a&gt;&amp;nbsp;-&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT-Object-Enabler-V8i-_2800_SS1_2900_-08.11.06.30en.exe.zip"&gt;communities.bentley.com/.../AutoPLANT-Object-Enabler-V8i-_2800_SS1_2900_-08.11.06.30en.exe.zip&lt;/a&gt;&amp;nbsp;-&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;If there is requirement for earlier AutoPLANT Object Enabler versions, please&amp;nbsp;post it in&amp;nbsp;&amp;quot;Comments or Corrections?&amp;quot; section and we will update this wiki with additional link to download it.&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/4335/bentley-autoplant"&gt;communities.bentley.com/.../bentley-autoplant&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/11306/autoplant-modeler-faq"&gt;communities.bentley.com/.../autoplant-modeler-faq&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Comments or Corrections?&lt;/h3&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/AutoPLANT%20Object%20Enabler%20CONNECT%20Update%202%20x%2064%20apoe10020001en_updt2.exe.zip"&gt;communities.bentley.com/.../AutoPLANT Object Enabler CONNECT Update 2 x 64 apoe10020001en_updt2.exe.zip&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Any way to view AutoPLANT 2004 files?</title><link>https://communities.bentley.com/products/plant/f/autoplant-axsys-openplant-plantwise-forum/225650/any-way-to-view-autoplant-2004-files</link><pubDate>Thu, 10 Feb 2022 10:59:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:605289a2-3662-4c82-836a-2bf3d9496e2c</guid><dc:creator>Andrew May</dc:creator><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;We have some MDB files used in AutoPLANT 2004 - is there a way to view them through a front end (rather than the direct MDB Files)?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>