<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Bubalan Sundaram's Communities Activities</title><link>https://communities.bentley.com/members/f2ccd0ef_2d00_38ea_2d00_4b96_2d00_850f_2d00_2510d2d3708d</link><description>Recent activity for people in Bubalan Sundaram's community</description><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Open staad</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/108737/open-staad</link><pubDate>Mon, 13 Jul 2015 05:26:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f233e8b3-0b8e-4e2c-b441-f48a9c45a90f</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear All,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;saw the code to extract the geometry of the selected members in open staad.&lt;/p&gt;
&lt;p&gt;a.) by the same method, can anyone guide me to extract the design forces for selected members. (the force which is governing the design)&lt;/p&gt;
&lt;p&gt;b.) Also, when i copy the code to a different worksheet with other macro codes, i could not assign the code to the button.&lt;/p&gt;
&lt;p&gt;any suggestions?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Open staad help</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/108860/open-staad-help</link><pubDate>Thu, 16 Jul 2015 01:52:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5b90946a-54f6-4452-ad52-4d505d4175e1</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear all,&lt;/p&gt;
&lt;p&gt;can any one send me the vb macro to extract member end forces for the selected beams from open staad for start and end location of the designed loadcase.&lt;/p&gt;
&lt;p&gt;Iam new to open staad and trying to learn .&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>repeat command limitation</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/139370/repeat-command-limitation</link><pubDate>Fri, 04 Aug 2017 09:09:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:125d4dac-b50d-4554-bcb5-eab704520944</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear all,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Ive have tried to modela chimney using circular repeat command. but the steps to repeat does not go more than 99.&lt;/p&gt;
&lt;p&gt;Also the translational repeat command is not going more than 99.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;any help&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;My staad version: SS6, 20:07:11:90&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>IS456 Concrete desin</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/138505/is456-concrete-desin</link><pubDate>Fri, 14 Jul 2017 06:47:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4ebc66c9-c48c-45d7-be36-8407fba22354</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear All,&lt;/p&gt;
&lt;p&gt;i have a small doubt regarding, the display of failed members using &amp;nbsp;&amp;quot;Structure diagrams/design results/Show diagram (based on actual ratio)&amp;quot; for concrete if the section is not adequate.&lt;/p&gt;
&lt;p&gt;how to use the above method to display failed members for concrete, for steel we can use this to display failed members based on ratio.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Ask A Question I</title><link>https://communities.bentley.com/achievements/460ac7df-7ccc-4c42-a204-9e05eef3be09</link><pubDate>Fri, 14 Jul 2017 00:24:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e2ec0543-620c-49d0-9dc7-ccdbad6ef9e7</guid><dc:creator /><description>Ask a question in a forum.</description></item><item><title>Ask A Question II</title><link>https://communities.bentley.com/achievements/cd3cd235-25c1-476e-bb88-33a5705ca45a</link><pubDate>Fri, 14 Jul 2017 00:24:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:65fd72b0-22e6-458c-9836-46b69956288e</guid><dc:creator /><description>Ask 10 questions in a forum.</description></item><item><title>shear width to thickness ratio for AIJ</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/111679/shear-width-to-thickness-ratio-for-aij</link><pubDate>Mon, 28 Sep 2015 23:38:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ad4a060c-b7bb-43cb-8656-738a72c3baa5</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Hi all,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;can anyone please tell me how staad checks for shear width to thickness ratio for japanese code.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Exception[access violation]Raised! Aborting Analysis.....</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/103996/exception-access-violation-raised-aborting-analysis</link><pubDate>Mon, 19 Jan 2015 05:45:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e5125ea7-9897-4897-bdef-8ec1151c2516</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear All,&lt;/p&gt;
&lt;p&gt;I run a roof structure in which i get the following error and it terminates the analysis.&lt;/p&gt;
&lt;p&gt;Exception [Access Violation] Raised! Aborting Analysis....&lt;/p&gt;
&lt;p&gt;But other models run fine,&lt;/p&gt;
&lt;p&gt;can anyone solve the issue...&lt;/p&gt;
&lt;p&gt;Staad version: 20.07.10.64&lt;/p&gt;
&lt;p&gt;regards&lt;/p&gt;
&lt;p&gt;Bubalan&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>sign convection in member forces in a modal analysis</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/111039/sign-convection-in-member-forces-in-a-modal-analysis</link><pubDate>Tue, 15 Sep 2015 01:01:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:f4347065-2e96-42e3-9348-cb0e42fc4e00</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;dear all,&lt;/p&gt;
&lt;p&gt;1.) The member end forces in axial, shear is same in value except in sign convection, but why the moment value differs for only seismic force (only mass applied) case.&lt;/p&gt;
&lt;p&gt;example:&lt;/p&gt;
&lt;p&gt;member &amp;nbsp; &amp;nbsp; &amp;nbsp;L/c &amp;nbsp; &amp;nbsp; Node &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;Axial &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;Shear Y &amp;nbsp; &amp;nbsp; &amp;nbsp;Shear Z&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Torsion &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; MY &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; MZ&lt;/p&gt;
&lt;p&gt;1 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;1 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; 1 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;108.052 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;1.703 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; 3.425 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; 4.682 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; 30.392 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;9.581&lt;/p&gt;
&lt;p&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;301 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;-108.052 &amp;nbsp; &amp;nbsp; &amp;nbsp;-1.703 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; -3.425 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; -&amp;nbsp;4.682 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; -19.217 &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;-15.312&lt;/p&gt;
&lt;p&gt;can anyone explain why only moment value differs?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>AIJ design calculation verification</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/108501/aij-design-calculation-verification</link><pubDate>Mon, 06 Jul 2015 00:05:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:e3a33274-e9e8-4b5f-8c1f-c870b5fc89c3</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear All,&lt;/p&gt;
&lt;p&gt;Can we extract design calculation like in MIDAS for AIJ in STAAD?&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>staad pro doesn&amp;#39;t recognize std files</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/104106/staad-pro-doesn-t-recognize-std-files</link><pubDate>Fri, 23 Jan 2015 00:30:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:817fc5ec-32c3-40fb-8caf-dcdea6cd34a7</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;staad pro doesn&amp;#39;t recognize std files , we have to manually select the program to open. any solutions welcome.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>AIJ seismic definition</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/103065/aij-seismic-definition</link><pubDate>Fri, 05 Dec 2014 23:56:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1f05dd15-1900-4698-863c-fff91117dad0</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Does defining the seismic force as per AIJ can have multiple member weight and joint weight commands, when i analyse the model, i find very less force generating &amp;nbsp;than the actual force to be generated.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>support reaction for a model with response spectrum load cases</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/102438/support-reaction-for-a-model-with-response-spectrum-load-cases</link><pubDate>Mon, 10 Nov 2014 05:21:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:5ff8c4c4-8a31-42de-8f03-bf169176a298</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;hello,&lt;/p&gt;
&lt;p&gt;can anyone tell me how to extract support reactions with sign (+/-) in a response spectrum model.&lt;/p&gt;
&lt;p&gt;For example, primary load case has SL+x. The civil designer needs SL-X, but since response spectrum load case uses modal super position, my values are absolute values.&lt;/p&gt;
&lt;p&gt;so if i give a combination having -1 as a factor for seismic load +X case, my reaction is all in negative.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;can anyone help!&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;thanks&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Forces for stiffener calculation</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/100546/forces-for-stiffener-calculation</link><pubDate>Fri, 29 Aug 2014 01:38:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b500e23d-eca4-4d4a-b20b-13ffad69cd7a</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear members,&lt;/p&gt;
&lt;p&gt;I want to design horizontal and vertical stiffeners for a plate girder in the structure. i have used STIFF parameter for spacing of vertical stiffener, also i had calculated its size manually using AISC 360-05 G2.2 but,&lt;/p&gt;
&lt;p&gt;I need to calculate the size of horizontal stiffener, so i need to extract the forces for web alone max and min from a combination to determine the stress at a particular location. is there a method to do that in staad?&lt;/p&gt;
&lt;p&gt;Code : AISC 360-05 , ASD for vertical stiffeners&lt;/p&gt;
&lt;p&gt;Code : AIJ , ASD for horizontal stiffeners&lt;/p&gt;
&lt;p&gt;regards&lt;/p&gt;
&lt;p&gt;Bubalan Sundaram&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>support reaction for concrete design</title><link>https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/99184/support-reaction-for-concrete-design</link><pubDate>Thu, 17 Jul 2014 09:42:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:82dfa1c6-b13d-4525-b18c-45b0bac0e62e</guid><dc:creator>Bubalan Sundaram</dc:creator><description>&lt;p&gt;Dear members,&lt;/p&gt;
&lt;p&gt;Since our model is a dynamic one, we have to give the primary support reaction to the concrete designers for their design. Since the dynamic support reaction will always be positive, how to give the primary reaction to the designers with sign convection?&lt;/p&gt;
&lt;p&gt;any body can help.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;regards&lt;/p&gt;
&lt;p&gt;Bubalan Sundaram&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>