My company has a customized setup. All of the DGNWS files reside in one directory called ”_DGNWS” (without the quotes). The WorkSets are in a separate directory and not a sub of the WorkSpace directory. The design model and sheet dgn files are located…
Hi,
We are having an issue when inserting steel beams / columns / railings from the catalog. They come in at the wrong scale - they are coming in at 100x smaller than the dimensions of the item. For example, a 400x200 RHS comes in 2mm wide. The walls…
I'm in the process of implementing changes to our companys workspace to get Connect Edition running.
We have previously had a very simple method of running Aecosim V8i, the only thing we did was setting a Windows System Variable (_USTN_WORKSPACEROOT…
Still in the process of setting up Aecosim Connect I've run into a problem when trying to setup our networked company workspace.
So far I was able to configure my PC that it reads configuration files from the network.
The problem I have now is that…
Following the directions, I have 44 users who have registered and logged in with Bentley Connect and are displayed in the User Management portion of the website. However, I continue to get angry correspondence that doom is a upon us as we have not successfully…
This article describes how to create a list of all configuration variables using MicroStation CONNECT Edition.
MicroStation CONNECT Edition Update 8 stopped working when Windows 10 Spring Creators Update was installed. Someone else happened to him?
Companion videos on YouTube:
Hi everyone,
It’s probably best to work through this written tutorial step by step but as a visual aid, I’ve created a series of companion videos and posted them on YouTube.You can find the playlist here: https…
Navigator CONNECT Edition 10 - 10.2.0.100
ProjectWise Explorer CONNECT Edition - 10.0.3.49
When opening .dgn files from ProjectWise, the file doesn't open, Navigator CONNECT holds on this screen:
The model does not open - is there any additional…
I need urgent assistance with making markups and then utilizing mark-up data in the current design file back in the office. (Perhaps referencing/syncing......something?)
What I can see is that we have the ability to create "punch lists" in Navigator…
One of the main areas of focus for MicroStation CONNECT Edition Update 10 was on improving performance, especially when accessing the backstage. During our investigations, it was found that some users were seeing a delay accessing the backstage when their…
The Configuration Assistant is designed to help a CAD Manager quickly create a CONNECT Configuration so they can re-use the CAD Standards from previous versions. The main purpose is to convert V8i WorkSpaces to CONNECT Configurations. The ability for a…
In real-world, multiple Bentley applications are used in tandem on a single project. Multiple domain-specific products built on top of MicroStation platform are used together. For example, in a large infrastructure project, AECOsim Building Designer …
Hello ProjectWise Product Management team.
Is Revit 2018 currently integrated with ProjectWise?
If yes, what version of ProjectWise?
If no, when is that anticipated to be available?
Thanks,
Michael
You may see issues with SELECTserver Online. Our development team is investigating and we will provide updates as a resolution is implemented.
The following and attachment is as complete a list of V8i Design File Settings keyins and VBA strings for 2D as I could find.
Usefull when running as a Batch Process routine to standardize design files.
Note: The accuracy numbers are the maximum allowed…
This video series follows this document: https://communities.bentley.com/products/road___site_design…
This is a basic overview of what configuration changes have been made within MicroStation CONNECT Edition.