<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>INGR TIFF Images Being Attached in the Wrong Location</title><link>https://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/27114/ingr-tiff-images-being-attached-in-the-wrong-location</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>INGR TIFF Images Being Attached in the Wrong Location</title><link>https://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/27114/ingr-tiff-images-being-attached-in-the-wrong-location</link><pubDate>Thu, 10 Mar 2016 21:10:38 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:97d047f6-6fee-4e65-a4ec-0737f28d004e</guid><dc:creator>fmcallis</dc:creator><comments>https://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/27114/ingr-tiff-images-being-attached-in-the-wrong-location#comments</comments><description>Current Revision posted to ContextCapture | Descartes | Pointools | Orbit Wiki by fmcallis on 3/10/2016 9:10:38 PM&lt;br /&gt;
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;MicroStation&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.608 &lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Raster&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;I upgraded from MicroStation V8.5 to MicroStation V8i and my INGR TIFF raster images show being attached in the wrong location.&lt;/span&gt;&lt;/div&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;Back in the 2004 edition Bentley couldn&amp;#39;t read the header of an INGR TIFF image in different units.&lt;span&gt;&amp;nbsp; &lt;/span&gt;In V8i we can now do that.&lt;span&gt;&amp;nbsp; &lt;/span&gt;If you’re INGR TIFF images have a header in Meters.&lt;span&gt;&amp;nbsp; &lt;/span&gt;It didn&amp;#39;t matter what the GeoTIFF unit in the preferences for raster manager was set to it would read as Meters every time it was attached.&lt;span&gt;&amp;nbsp; &lt;/span&gt;In 2004 your working units were set to work in Feet.&lt;span&gt;&amp;nbsp; &lt;/span&gt;So in V8i your working units were set in preferences to Feet. &lt;span&gt;&amp;nbsp;&lt;/span&gt;When you attached the INGR TIFF image it would read the header in Feet and it would be attached in the wrong location.&lt;span&gt;&amp;nbsp; &lt;/span&gt;Changing the raster file unit in Workspace&amp;gt; Preferences &amp;gt; Raster Manager &amp;gt; Georeference to Meters and then attaching the image gives the desired results.&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;=================================================&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;b&gt;&lt;span&gt;MS_RASTER_IGNORE_INGRTAGS_WITH_GEOTIFFTAGS &lt;/span&gt;&lt;/b&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;=================================================&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;Your INGR TIFF image has 2 headers.&lt;span&gt;&amp;nbsp; &lt;/span&gt;In MicroStation V8.5 this was not a problem.&lt;span&gt;&amp;nbsp; &lt;/span&gt;In MicroStation XM and V8i Raster Manager is reading the INGR TIFF header instead of the GEOTIFF header.&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;Please try the following.&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;p class="CxSpFirst" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;1)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Opened the DGN file in XM or V8i.&amp;nbsp; &lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;2)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;In Workspace &amp;gt; Configuration &amp;gt; &lt;b&gt;New&lt;/b&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;3)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Variable:&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;b&gt;MS_RASTER_IGNORE_INGRTAGS_WITH_GEOTIFFTAGS&lt;/b&gt; &lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;4)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Variable Value:&lt;span&gt;&amp;nbsp; &lt;/span&gt;&lt;b&gt;1&lt;/b&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;5)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;Detach the TIFF image.&amp;nbsp; &lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;6)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Exit MicroStation completely.&amp;nbsp; &lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;7)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Go into MicroStation &lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpMiddle" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;8)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Attach the TIFF image.&amp;nbsp; &lt;/span&gt;&lt;/p&gt;
&lt;p class="CxSpLast" style="margin:0in 0in 10pt 0.5in;line-height:115%;text-indent:-0.25in;margin:0 0 .0001pt .5in;"&gt;&lt;span&gt;&lt;span&gt;9)&lt;span&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span&gt;Double click on the raster image in Raster Manager.&amp;nbsp; If the variable is being recognized correctly in Element Information &amp;gt; Image &amp;gt; Format will show as GEOTIFF.&amp;nbsp; If it shows INGR TIFF then it is not recognizing the Environment Variable correctly.&amp;nbsp; &lt;/span&gt;&lt;/p&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;NOTE:&lt;span&gt;&amp;nbsp; &lt;/span&gt;If you have multiple workstations attaching INGR TIFF raster images then you will need to define the MS_RASTER_IGNORE_INGRTAGS_WITH_GEOTIFFTAGS &amp;nbsp; environment variable in MicroStation on all of your workstations.&lt;span&gt;&amp;nbsp; &lt;/span&gt;The MS_RASTER_IGNORE_INGRTAGS_WITH_GEOTIFFTAGS &amp;nbsp; environment variable is only valid for MicroStation XM and V8i.&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;Your raster image should now be attaching correctly in Raster Manager.&lt;span&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&lt;a href="http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25024.raster-image-being-attached-in-the-wrong-location"&gt;&lt;font color="#0563c1"&gt;http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25024.raster-image-being-attached-in-the-wrong-location&lt;/font&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&lt;a href="http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25009.attached-raster-image-is-not-listed-in-raster-manager"&gt;&lt;font color="#0563c1"&gt;http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25009.attached-raster-image-is-not-listed-in-raster-manager&lt;/font&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&lt;a href="http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25038.view-toggles-in-raster-manager-stay-grey-when-trying-to-turn-the-view-on"&gt;&lt;font color="#0563c1"&gt;http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25038.view-toggles-in-raster-manager-stay-grey-when-trying-to-turn-the-view-on&lt;/font&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&lt;a href="http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25013.dgn-with-raster-images-attach-crash-hang-or-raster-image-does-not-display"&gt;&lt;font color="#0563c1"&gt;http://communities.bentley.com/products/3d_imaging_and_point_cloud_software/w/wiki/25013.dgn-with-raster-images-attach-crash-hang-or-raster-image-does-not-display&lt;/font&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style="margin:0in 0in 0pt;"&gt;&lt;span&gt;&lt;/span&gt;&amp;nbsp;&lt;/div&gt;
&lt;p&gt;&lt;/p&gt;&lt;img style="border-left-width:0px;border-right-width:0px;border-bottom-width:0px;border-top-width:0px;" alt=" " src="http://communities.bentley.com/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" /&gt; 
&lt;table style="border-top:#dce5f0 0px solid;border-right:#dce5f0 0px solid;border-bottom:#dce5f0 0px solid;border-left:#dce5f0 0px solid;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Frank McAllister&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Raster, MicroStation, en, SELECTsupport, 08.11.09.608&lt;/div&gt;
</description></item></channel></rss>