• Openxxxxx Client Workspace Configuration Redeployment Stress Test

    I Folks- I am looking to see if any admins out there are doing any pre-configuration-deployment "Stress Test" (I had in mind similar to a Software Test Plan procedure) on their Client Configs prior to releasing them to projects for production work? …
  • Role Specific DGNLIB with Item Types and Report Definition

    Hi Everyone, I am trying recently to learn a little bit more about MicroStation workspace, workset and role configuration files. I am currently using MicroStation Connect Edition Update 16 (Version 10.16.01.56). My goal is to create a role specific…
  • Power GEOPAK V8i - Can't Open Macro File

    In trying to setup both SCDOT and NCDOT workspaces in my Microstation GEOPAK, I've caused an issue that I can't seem to fix. When I start MS, this window opens with the mesasge "can't open macro file [C:\Program files (x86)\Bentley\PowerGEOPAK V8i (SELECTseries…
  • [V8i] User Preferences & Configuration - UPF Saves but Updates Don't Apply

    PowerGEOPAK V8i (SELECTseries 10) Version 08.11.09.918 Power InRoads V8i (SELECTseries 4) Version 08.11.09.878 Windows 10 Pro Version 1809 OS build 17763.503 REQUEST: I'm trying to debug an issue I'm sure I caused when setting up a new company…
  • User adding own dgnlib cuts out existing menu customisations?

    As a user entering a new workplace/workspace I am wanting to add my own dgnlib containing MenuBar customisations. I can do this by either using the Workspace>Customize menu and appending my dgnlib or manually entering it into the ucf file such that it…
  • Redirect Connect to our server

    I think I got Microstation Connect to redirect to my server. I modified the C:\ProgramData\Bentley\CONNECT Edition\Configuration\WorkSpaceSetup.cfg file to point to my server which contains the file structure: K:\WWE Configuration\ K:\WWE Configuration…
  • Project Explorer : Mix Folder Link and Configuration variable link

    Hello, Is it possible to create a link which mix Folder Link and Configuration Variable Link ? With a Folder Link, I can have very quickly all the content of a specific folder (folders and subfolders and so on), but I have all the files . With…
  • v8i - UCF vs PCF

    I noticed that if I placed a configuration variable in both the UCF and the PCF, then the UCF was "cancelling" the PCF. In both files, I was using the ">" sign to append the definition. For example, I had MS_MACRO defined in both, using the ">". The…
  • Automatic MS_RFDIR Creation

    I am working on a major revision to our network workspace and am trying to build the MS_RFDIR configuration variable with our knowing all of the possible directories that will need to be included. I have a base set of directories to include in this…
  • V8i SelectSeries 2 Workspace Preferences

    Is there a way that we can disable the users from setting the workspace preferences? We would like to disable the "Save Settings on Exit" under Workspace Preferences Operation. Can we grey it out so the users can't change the setting?
  • Graphic User Interface redistribution

    I would like to duplicate a Graphic User Interface (tool bar layout) on all my PC's or at least make it available to the users so they can select it. It would also be nice to make the individual interface for each user available when they move from…