The error below shows :
1) In eB Rendition queue when trying to render a file
2) In eB FTR queue when adding a file to a class enabled for FTR
Retrieving the COM class factory for component with CLSID {CAC2C26A-4215-11D0-98FB-08003601E054} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)). Exception Stack Trace: { --- Begin of exception stack trace --- System.Exception: Retrieving the COM class factory for component with CLSID {CAC2C26A-4215-11D0-98FB-08003601E054} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)). at eB.Management.QueueJobHelper.InvokeCustomEngine(QueueEngineProcess qep, String engineDll, String engineNamespace, String proxyConnectInfo, IDictionary`2 jobAttributes) at eB.Management.QueueJobHelper.ProcessQueueEntry(Object sender, PollEventArgs e) --- End of exception stack trace --- }
Retrieving the COM class factory for component with CLSID {CAC2C26A-4215-11D0-98FB-08003601E054} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)).
Exception Stack Trace:
{
--- Begin of exception stack trace ---
System.Exception: Retrieving the COM class factory for component with CLSID {CAC2C26A-4215-11D0-98FB-08003601E054} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)).
at eB.Management.QueueJobHelper.InvokeCustomEngine(QueueEngineProcess qep, String engineDll, String engineNamespace, String proxyConnectInfo, IDictionary`2 jobAttributes)
at eB.Management.QueueJobHelper.ProcessQueueEntry(Object sender, PollEventArgs e)
--- End of exception stack trace ---
}
eB uses the Projectwise Interplot Server components to render files to different file formats. This is offered as an option in version 15.5.1, and as render/print solution in eB15.6.1.
To Install and configure Projectwise Interplot Server Do the following:
1. Download current version of Projectwise Interplot Server from SELECTServices. Your Download will also include Installation of server pre-requisites.
2. First run the install of server pre-requisites in eB application server.
3. Run Full Installation of Projectwise Interplot Server.
4. In order to render Microsoft Office files such as Word documents and Excel spreadsheets, Install Ghostscript freeware on the server. For more information on where to find Ghostscript components, see http://communities.bentley.com/products/assetwise/assetwise_platform/w/wiki/12177.eb-where-to-find-ghostscript-software-for-eb-interplot-configuration.aspx
5. You will need to add a PostScript Printer to be used in Projectwise Interplot Organizer configuration
a) Open the “Devices and Printers” Window: Control Panel -> Hardware and Sound -> Devices and Printers
b) Select “Add a Printer”
c) Select “Add a local printer”
d) Select the radio button “Use an existing port:”
e) Select “FILE: (Print to file)” from the drop down
f) Select “HP” in the left (Manufacturer) pane
g) Select “HP Color LaserJet 2800 Series PS” in the right (Printers) pane
h) Install the drivers
6) In order to render Microsoft Office files such as Word documents and Excel spreadsheets, InterPlot Organizer needs to be configured to do so. Using the Configuration Tool, do the following:
a) Open the configuration tool: Start -> Programs -> Bentley -> ProjectWise InterPlot Utilities -> ProjectWise InterPlot Organizer Configure
b) Select “Integrate”
c) Select the “Office” tab
d) Fill in form as shown below: