Set up the Exor Listeners on the application server, to run server modules such as UKPMS and Structures Manager loaders.
You will need to make a note of the following locations and create them if they don't exist. All of these will be on the application server.
START FILE:
set PROD_HOME=c:\exor\bin[1]
set PROD_REPORTS=c:\exor\reports\[2]
set FMT_FILEPATH=c:\exor\fmtfiles\[3]
set DB_ALIAS=exorsystem[4]
C:\exor\bin\exorlsnr highways[5]/password@exorsystem[6] start –d[7]
STOP FILE:
set PROD_HOME=c:\exor\bin
set PROD_REPORTS=c:\exor\reports\
set FMT_FILEPATH=c:\exor\fmtfiles\
set DB_ALIAS=exorsystem
C:\exor\bin\exorlsnr highways/password@exorsystem stop
If you are running listeners for more than one Highways instance on the same Application Server, you need to make sure that they have different settings for the GRILSTNAME product option otherwise there will be clashes with pipe files. If you are going to change GRILSTNAME do NOT do it while the listeners are running – stop them first!
If 'Exor Listeners are not running' message is encountered: http://communities.bentley.com/products/assetwise/exor/w/wiki/exor-listener-processes-are-not-currently-running.aspx
Resetting the listeners if a module has crashed with a fatal error: http://communities.bentley.com/products/assetwise/exor/w/wiki/11917.exor-listeners-do-not-execute-requests.aspx